Page 11

PROGRAMMING YOUR SCANNER To program your scanner: 1. Power-up the scanner to be programmed by plugging the power cord into the scanner and an electrical outlet of the appropriate voltage. Wait for the scanner to complete the selftest routine and emit a tone. The green lamp will light steadily, indicating that the scanner is in normal Operating Mode. 2. Put the scanner into Programming Mode by scanning the Switch Label (located on page 14 and on the inside of the back cover). The green LED flashes continuously indicating that the scanner is in Programming Mode.

R44-1340

7

Page 12

3.

4.

8

Scan a programming label(s) for the feature you want to change. The scanner will emit a 'good read' tone to indicate that the label has been read and the setting has been stored in the scanner’s memory. Scan the remaining programming labels as required. If a label scanned is not a valid programming label, the scanner will emit a low rejection tone. After all the desired programming labels have been successfully scanned, exit Programming Mode by pressing the Operator switch or scanning the Switch Label. The green lamp will light dimly, indicating that the scanner is ready for normal operation.

VS1200 & HS1250 Programming Kit

Page 13

PROGRAMMING CONVENTIONS •

•

•

R44-1340

All options set while in Programming Mode are stored in default memory, and will be retained even if the scanner is powered-down. Settings are stored on a first-in, firstout basis. The last programming label scanned for a given option is the setting stored in memory. For example, if a programming label which sets the baud rate at 9600 is scanned, followed by a label which sets the baud rate at 19,200, the scanner will be programmed with a baud rate of 19,200. Only labels included in this manual will be accepted as valid programming labels. Labels which attempt to set features not implemented in a scanner’s software revision will be rejected as invalid. Programming labels which are not printed in accordance with industry standards may also be rejected.

9

Page 14

•

•

•

10

If an invalid label is scanned when in Programming Mode, the scanner will emit a low tone to indicate that the label is either not a programming label or that it contains values outside of the acceptable programming range. After five minutes of inactivity in Programming Mode, the scanner will revert to normal Operating Mode. Any options set during the programming session will be stored and activated. If confusion arises as to which options have been set during a programming session, scanning the Return to Factory Settings label will reset the scanner to the original factory defaults for all options, regardless of interface type. We recommend that you use the table provided in the back of this manual to record all changes that you make. This will help to ensure that you can record all modifications that you have made to the factory default configuration. This will be very helpful if you must return the VS1200 or HS1250 to the factory default settings. VS1200 & HS1250 Programming Kit

Page 15

PROGRAMMABLE FEATURES The remainder of this manual includes programming labels for all VS1200 or HS1250 programmable features. Refer to the detailed features listing shown in the index at the back of this manual to find the individual features that you wish to change.

SPECIAL LABELS There are three programming labels in this manual that work differently from all the other labels included in this Programming Guide; the Increment Volume, Increment Tone, and the Switch labels. Increment Volume works without entering Programming Mode, but its volume selection is lost when power is removed from the scanner. Increment Tone works without entering Programming Mode, but its tone selection is lost when power is removed from the scanner. The Switch label is the key that allows you to enter and exit Programming Mode. R44-1340

11

Page 16

INCREMENT VOLUME The Increment Volume label affects the scanner when in normal Operating Mode. Each pass of the label increments the speaker volume to the next loudest available level. When the highest of the three available levels is reached, the sequence starts again at the quietest level. If speaker volume is set using this label, the scanner reverts to the default volume setting when power to the scanner is interrupted. To permanently store changes to the speaker’s default volume use the labels titled, Speaker Volume, later in this manual.

Increment Volume 12

VS1200 & HS1250 Programming Kit

Page 17

INCREMENT TONE The Increment Tone label affects the scanner when in normal Operating Mode. Each pass of the label increments the speaker tone to the next highest available level. When the highest of the three levels is reached, the sequence starts again at the lowest level. If speaker tone is set using this label, the scanner reverts to the default tone setting when power to the scanner is interrupted. NOTE The VS1200 Class 39 scanners do not support this option.

Increment Tone R44-1340

13

Page 18

SWITCH LABEL Like the Increment Volume and Tone labels, the Switch label affects the scanner when in normal Operating Mode. Scanning the Switch label in normal Operating Mode causes the scanner to enter Programming Mode. Scanning the Switch label while in Programming Mode instructs the scanner to save all changes made while in Programming Mode, exit Programming Mode, reset the scanner to implement the changes you made, and return to normal Operating Mode. All programming sessions must begin with the Switch label for the scanner to recognize them as programming labels and end with the Switch label or press the button (or allow programming mode to time out) in order for the scanner to store the changes you have made.

Switch 14

Label

VS1200 & HS1250 Programming Kit

Page 19

RETURN TO FACTORY DEFAULT Use this label to return the scanner or scanner/scale to the factory default settings.

6 500000 000009 R44-1340

15

Page 20

PROGRAMMABLE SPEAKER FEATURES The speaker has three programmable features:

16

•

Good Read indicator can be turned on or off.

•

Good Read volume can be set to one of three levels. The volume can either be changed temporarily using the switch on the top of the scanner, Increment Volume label, or its default can be reprogrammed using the programming labels on the following pages.

VS1200 & HS1250 Programming Kit