For the PSC HS-1250 and Datalogic HS-1250

Page 1

VS1200 &

HS1250 Programming Kit

Page 2

PSC Scanning, INC. 959 Terry Street Eugene, Oregon 97402-9120 Telephone: (541) 683-5700 Toll Free: (800) 547-2507 Telefax: (541) 686-1702

PSC AND THE PSC LOGO ARE REGISTERED TRADEMARKS OF PSC INC. This manual and its contents are copyrighted, with all rights reserved. Under copyright law, this manual may not be copied in whole or in part without the prior written consent of PSC. The same proprietary and copyright notices must appear on any permitted copies as appear on the original. This exception does not permit copies to be made for others, whether or not sold. Under the law, copying includes translating into another language or format.

DISCLAIMER The information and specifications contained in this manual are subject to change without notice. PSC shall not be held liable for damages resulting from the use or misuse of the information contained herein.

Page 3

Table of Contents ABOUT PROGRAMMING ......................................................... 1 SCANNER PROGRAMMING (HOW IT WORKS) ........................................................ 5 PROGRAMMING YOUR SCANNER ...................................... 7 PROGRAMMING CONVENTIONS ......................................... 9 SPECIAL LABELS ............................................................... 11 INCREMENT VOLUME ................................................... 12 INCREMENT TONE ....................................................... 13 SWITCH LABEL .......................................................... 14 RETURN TO FACTORY DEFAULT ...................................... 15 PROGRAMMABLE SPEAKER FEATURES ..................................... 16 SPEAKER VOLUME PROGRAMMING .................................. 21 UPC/EAN PRICE/WEIGHT CHECK DIGIT SELECTIONS ................................................... 28 TIMEOUTS ....................................................................... 34 SETTING LASER TIMEOUT ............................................. 35 SETTING MOTOR TIMEOUT ........................................... 39 SETTING DOUBLE READ TIMEOUT ................................... 44 PERIPHERAL PORT ............................................................. 48

R44-1340 i

Page 4

CHANGING BARCODE TYPES ................................................. 56 UPC/EAN EXPANSION ............................................... 58 UPC CHECK DIGIT TRANSMISSION ................................. 64 CODE 39 ................................................................. 73 CODE 128 ............................................................... 83 INTERLEAVED 2 OF 5 ................................................... 97 INTERFACE SELECTIONS ..................................................... 139 RS-232 INTERFACE SPECIFICATIONS ............................ 139 OCIA INTERFACE SELECTION ...................................... 162 OCIA/RS-232 DUAL INTERFACE ................................ 169 MULTIDROP SCANNER ADDRESSING .............................. 178 INDEX ........................................................................... 183 ii

VS1200 & HS1250 Programming Kit

Page 5

VS1200 & HS1250™ PROGRAMMING W/BARCODES This programming guide contains the procedures and barcode programming labels necessary to set VS1200 and HS1250's programmable features.

ABOUT PROGRAMMING The following list shows an overview of this manual’s organization. We have divided the contents into groups of features that are usually changed together. For example, all of the RS-232 parameters (baud rate, parity, stop bits, etc.) are grouped together. • About Programming • Special Labels (Switch label, Increment Tone & Increment Volume) • Return to Factory Default • Operational Settings (Speaker, Laser & Motor Timeouts) R44-1340

1

Page 6

• • •

RS-232 Parameters (Baud Rate, etc.) Symbology Selection Interleaved 2 of 5 Label Length

Check the Index for the location of specific programming labels. This introduction describes the programming and configuration procedures for the VS1200 & HS1250. Scanner Programming: describes how to put the scanner in Programming Mode and how to use the programming barcodes to set the scanner’s parameters. Special Labels: includes a set of labels which perform unique functions and cannot be duplicated by standard label definition and printing equipment. Each special label affects the scanner when in normal operating mode. These include: • Programming Switch Label - puts the scanner in Programming Mode and exits from Programming Mode. • Increment Volume Label - changes the speaker volume setting in volatile (temporary) memory. If power to the

2

VS1200 & HS1250 Programming Kit

Page 7

scanner is interrupted, the volume will revert to the default setting. Return to Factory Settings: resets the scanner to the original factory settings for all options. Any special features or options programmed prior to scanning this label in Programming Mode must be reselected. User Features: allow selection of On/Off Switch, Laser Timeout, Motor Timeout, Peripheral Port, Speaker Volume, Double Read Timeout interval, and Price/Weight Check Digit read and transmission. When the speaker's volume is programmed with these labels, the setting is stored in default memory. If power to the scanner is interrupted, the volume setting is retained.

R44-1340

3

Page 8

RS-232 Communication Format : settings are used only with scanners which have an RS-232 interface. Options include Data Bits, Baud Rate, Parity, Handshake, Stop Bit, and Prefixes. OCIA Communication Format : is used only with scanners that have an OCIA communication interface. The labels in this manual allow you to change OCIA interface types and enable or disable an Intercharacter Delay. Symbology Selection: allow selection of the types of barcode (symbologies) the scanner can read. These features also include UPC/EAN Expansion, control the calculation and transmission of check digits for Code 39. If Interleaved 2 of 5 symbology is selected, label length settings are required.

4

VS1200 & HS1250 Programming Kit

Page 9

SCANNER PROGRAMMING (HOW IT WORKS) The VS1200 & HS1250 features advanced programming capabilities which lets you change the scanner’s configuration and functional behavior by using the EAN-13 programming labels in this manual. The scanner’s operating parameters are held in three different portions of memory. • RAM (Random Access Memory) holds the current operational settings while the scanner is powered-up. These settings are lost when power to the scanner is removed. For example, the Increment Volume label changes the volume setting held in RAM, but is lost when power to the scanner is interrupted. RAM is temporary or ‘volatile’ memory. • Default Memory is stored in the EEPROM and holds the operational settings that are loaded to RAM each time

R44-1340

5

Page 10

•

6 the scanner is powered-up. This portion of memory is preserved even if the scanner is powered down. All settings made through the Programming Mode are stored in default memory. Permanent Memory is also stored in the EEPROM and holds the factory programmed settings for all of the scanner’s operational parameters. The contents of permanent memory are loaded into default memory when the Return to Factory Settings label is scanned. The contents of permanent memory can only be modified at the factory. By entering the ‘Programming Mode’ the desired characteristics can be set in default memory by scanning barcode programming labels. These settings are saved even if the scanner is powered down.

VS1200 & HS1250 Programming Kit