Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 6

Duet Scanner User's Guide, pages 19 to 27

Pages 19 to 27 of 51

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC Duet

Page 19

Figure 9. Installing Stand to Countertop a b a. Stand b . Countertop

Mounting the Stand using Screws The scanner base may be attached to the countertop using the mounting screws provided. Use the template at the back of this manual to help locate the mounting holes. The following procedures refer to Figure 10 on the next page. 1.

Position the template where you want to install the scanner. Use the template at the back of this manual to locate the holes for the two mounting screws.

User's Guide

17

Page 20

2.

Mark the hole position and drill two pilot holes, approximately 1/8 inches (.3 cm) diameter and 3/4 inches (2.0 cm) deep, into the countertop.

3.

Install the two mounting screws, but do not tighten. Leave the heads of the screws approximately 5/16 inches (1 cm) above the countertop as shown in panel 3 on the opposite page.

4.

Place the scanner stand over the two mounting screws, aligning the large openings with the screw heads.

5.

Twist the stand firmly, but gently, in a clockwise direction to engage the screws in the baseplate slot.

NOTE It may be necessary to readjust the height of the mounting screws to obtain a good fit. The mounting screws should be adjusted until no up and down movement of the base is detected, but not so tight as to prevent the base from being removed from the mounting screws.

6.

This completes the stand installation.

You may wish to drill an additional 3/4 inch (2.0 cm) hole near the scanner for routing the interface cable to the host terminal.

18

Duet ™ Scanner

Page 21

Figure 10. Installing the Scanner Stand

1

2 a d hes ) inc 2.5 5 cm (6.3 c

Front

C

PS et Du ide Gu er's

Us b

3 b

4 f e

5

6 g a. Template b. Countertop c. Drill two pilot holes d. Drill

User's Guide e. Approximately 5/16 inches f. Mounting Screws g. Stand Installation Complete

19

Page 22

Connecting the Scanner The Duet scanner connects to the store host terminal via an interface cable. The cable connects to the scanner with a modular connector and to the host terminal with the connector required by the host (RS-232, OCIA, Keyboard Wedge, Wand or IBM POS). DC power to the scanner is supplied by one of two methods: 1.

From the host terminal (Power-Off-Terminal) through a special cable that carries both data and DC power.

2.

From an optional AC/DC power supply that provides DC power, either through the side of a connector, or connected to a special connector attached to the interface cable.

Figure 11 shows how to connect the scanner to the store host terminal. The type of DC power connector depends on your existing store host terminal.

Power-Up Procedure The system power-up procedure may vary depending on the requirements of your Point-of-Sale (POS) system. Always power-down (switch off) all equipment prior to connecting cables. Check with your system supervisor and/or refer to the terminal operator's manual for proper power-down and power-up procedures for your system. To connect the scanner: Power-Off-Terminal (P.O.T.) 1.

Connect the interface cable to the scanner.

2.

Connect the interface cable to the host terminal.

Power-up the system and scan a few items to verify that data is properly communicated between the scanner and your POS terminal.

20

Duet ™ Scanner

Page 23

AC/DC power supply (if required) 1. 2.

Connect the interface cable to the scanner. Connect the DC barrel plug into the side of the connector, or into the DC power connector. 3. Connect the interface cable to the host terminal. 4. Plug the AC/DC power supply into a functional AC outlet. Power up the system and scan a few items to verify that data is properly communicated between the scanner and your POS terminal. Figure 11. Connecting the Scanner to the Host Terminal a. Interface Connector b. DC Power Connector c. Host Terminal Connector* d. To Host Terminal e. Interface Cable f. AC/DC Power Supply

*Your Host Terminal Connector may vary from illustration

User's Guide

21

Page 24

You have completed the scanner installation and power-up procedures. If problems occur, follow the procedures titled Problem Isolation on the next page. If you want to modify the scanner's interface parameters or change the user interface (e.g. speaker tone length), order the Duet scanner Programming Guide (PSC Part Number R44-1740).

22

Duet ™ Scanner

Page 25

Troubleshooting Problem Isolation START

Is the LED flashing brightly? Are multiple tones emitted ? NO

Go to the Isolated** Scanner Test flowchart on the next page.

YES

NO

Does the scanner read bar codes ?

Is the YES Green lamp lit (dim)* ? *If the green lamp is flashing NO

**You will need an AC/DC power supply and an interface cable that accepts external power in order to isolate and verify the scanner's operation.

YES slowly, the scanner is in the Sleep Mode. Wave your hand near the Front Scan Window to "wake it up," or press the trigger switch.

Does NO your scanner use AC/DC power supply ?

Move the scanner to a known good terminal,or replace the interface cable.

YES

YES

Is the data displayed on the terminal ? NO

Verify that the 1. Interface cable is plugged into the scanner. 2. DC power plug is connected to the barrel-type plug on the interface cable. 3. AC/DC power supply is connected to a functional AC outlet. (Reference Figure 10).

Problem is: • terminal • interface hardware or • interface software Call your system support personnel No Problem Found

User's Guide

23

Page 26

Isolated Scanner Test NOTE If you have a scanner that uses Power-Off theTerminal (P.O.T.), you cannot perform this test unless you are able to substitute a cable that uses an AC/DC power supply connected as shown in Figure 10.

1. Disconnect Power Disconnect the AC/DC power supply from the AC power outlet.

2. Disconnect Interface Disconnect the scanner's interface cable connector from the host terminal.

Did the scanner pass Selftest ? YES

Is the green LED lit dimly ? YES

3. Reconnect Power After you have disconnected the interface cable connector, reconnect the AC/DC power supply.

Will the scanner read bar codes* ? YES

4. Selftest Routine The scanner performs a complex Power-Up Selftest that checks operation of the scanner hardware and software. If successful, the beeper sounds four tones and the green lamp lights, indicating the scanner passed the Selftest.

NO

Potential problems: • Record the number of tones emitted by the scanner. Call your system support personnel. NO

Potential problems: • Lamp failed • Scanner failure Call your system support personnel.

NO

Potential problems: • Poor bar code quality • Bar code symbology is not enabled • Scanner failure Call your system support personnel.

Scanner O.K. Problem is either interface cable, or terminal.

* With the interface cable disconnected from the host terminal, the scanner may only read one or two bar codes before it must be reset. Unplug and reconnect the AC/DC power supply to reset the scanner.

24

Duet ™ Scanner

Page 27

How To Scan With two scan windows, the Duet scanner can easily adapt to either fixed/portable or targeted handheld scanning applications. The front scan window, with its multiple scan pattern, is used for most retail items. The rear scan window emits a single targeted scan pattern for handheld scanning of hard to read or bulky items, or to read an individual bar code among many bar codes.

Fixed Mode Scanning Fixed Mode scanning provides ease of use by reducing the need to pick up the scanner to read a bar code. Its specially designed scan pattern minimizes the need for the operator to adjust the item for scanning. The scanner stand adjusts forward and backwards to an optimal and comfortable position for increased efficiency. For most applications, the best scanning position is straight up and down. Figure 12 shows the range of movement available. Figure 12. Scanner Position Adjustment a. Optimal position for most applications

User's Guide

25