The text of a manual · part 3 of 11
Installation and Operation Manual, LazerData Series 9000E Barcode Scanner/Decoder, pages 21 to 30
Pages 21 to 30 of 104
The original document is the PDF (714 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC 9000 and Datalogic 9000
Page 21
INSTALLATION
In addition to being the correct distance from the scanner, the scan line must pass through the entire code symbol including the quiet zone at the beginning and end of the code. The quiet zone is a white area at least ten times the width of a narrow bar in the code. This is illustrated in Figure 3-4 below.
Scanning Beam Position Figure 3-4
The more times the scanning beam passes through the entire code symbol, the greater is the probability of successfully reading the code. Figure 3-5 shows a method of calculating the number of passes the scanning beam will make over the code symbol for two orientations. In order to perform this calculation the user must know the speed, orientation of the code symbol ("Ladder" or "Picket Fence"), the distance from the scanner to the code and the dimensions of the bar code. In addition, the sweep speed of the scanner and the scanning beam width must be known. The scan speed was specified when the scanner was ordered. The beam width can be determined using Figure 3-3. If the user has a choice of mounting orientation, data for both orientations should be calculated. The orientation yielding the most sweeps over the code should be used.
3-7
Page 22
Series 9OO0E Scanner/Decoder
“LADDER” ORIENTATION aul BEAM MOTION OO \O es)
CODE MOTION oO Ne) VN] Ws es) es) DO a eu)
em a - a - We
N= F x We 7 WV)
WHERE:
F = BEAM SWEEPR/SECOND
WIDTH OF SCAN
WIDTH OF CODE SYMBOL Cin) VELOCITY OF SYMBOL ‘Cin/sec> NUMBER OF SWEEPS OVER CODE
Ss = c=
CODE MOTION
| 1246334603168e We, - __ - Ws
N= F x [Ws - Wo) / VI]
Beam Sweeps Over Code Figure 3-5
Ts BEAM MOTION a
Page 23
INSTALLATION
RASTER Some models of the Series 9000E Scanner/Decoder are supplied with a raster scan option. Not only does the beam scan horizontally but it is also incremented vertically so as to sweep an area. The area covered depends on the raster deflection and the distance from the scanner. The unit is available with 5o, 10o, 20o, and 30o deflection. Figure 3-6 below shows the area covered for various deflections and distances from the scanner. For 500-scan/sec. models, six sweeps of the beam are equally spaced over the raster height. For 1000-scan/sec. models, twelve sweeps are equally spaced over the raster height.
Raster Width for Various Operating Distances Figure 3-6
3-9
Page 24
Series 9000E Scanner/Decoder
3-10
Page 25
SIGNAL INTERFACES
INTRODUCTION All interface signals are contained on three D-type subminiature connectors at the rear of the scanner housing. Connectors are labeled LOCAL, HOST, and USER I/O. The LOCAL Connector contains the RS232C signals for a serial terminal that can be used to program the system parameters and monitor activity. The HOST Connector contains the RS-232C, RS-422, or optional RS-485 signals that will be sent to the host computer or other control device. The USER I/O Connector provides logic level status pulse outputs, gating and push-button compare inputs. A 5-pin circular connector supplies power to the scanner. +5 VDC, and +12 VDC are required.
LOCAL PORT This port is designed to accept a serial RS-232 terminal to configure the system operating parameters and monitor scanner operation if desired. It is set to 9600 baud, 1 start bit, 8 data bits, no parity bit, 1 stop bit (9600 N81) at manufacture. A 50-foot maximum cable length is suggested. Interface is through a DE9P connector as shown below.
DE9P Connector
PIN
NAME
DESCRIPTION
4-1
DIRECTION
Page 26
Series 9000E Scanner/Decoder 1
N/C
No Connection
2
TXD
Transmit Data
Out
3
RXD
Receive Data
In
4
N/C
No Connection
5
GND
Common Ground
6
N/C
No Connection
7
N/C
No Connection
8
N/C
No Connection
9
N/C
No Connection
Pin 2
TRANSMIT DATA - Data Transmitted from the SERIES 9000E SCANNER/DECODER to the local programming terminal. Transmission format is serial ASCII, 1 Start Bit, 8 Data Bits, No Parity Bit, 1 Stop Bit. Baud rate is set at 9600.
Pin 3
RECEIVE DATA - Data transmitted from the local programming terminal to the Series 9000E Scanner/Decoder. Transmission format is serial ASCII, as above.
Pin 5
COMMON GROUND - Ground terminal common to both Transmit and Receive Data Lines.
HOST PORT The Host Port is designed to provide RS-232, RS-422, or optional RS485 communications to a host computer or other intelligent peripheral device. The type of communications used is user-programmable and is selected on Page 3 of the Programming Menus. When selecting RS232
4-2
Page 27
SIGNAL INTERFACES communications, a 50-ft. maximum cable length is suggested. With RS-422 or RS-485 communications, cable lengths up to 500 feet can be used. Interface is made via a DE9S connector as shown below. Pin assignments vary depending on the hardware protocol selected. Connections for the various protocols are shown in the following tables.
DE9S Connector RS-232 Connections PIN
NAME
DESCRIPTION
DIRECTION
1
N/C
No Connection
2
TXD
Transmit Data
Out
3
RXD
Receive Data
In
4
DSR
Data Set Ready
In
5
GND
Common Ground
6
DTR
Data Terminal Ready
Out
7
CTS
Clear to Send
In
8
RTS
Request to Send
Out
9
N/C
No Connection
Pin 2
TRANSMIT DATA - Data transmitted from the Series 9000E Scanner/Decoder to the host computer. Transmission is serial ASCII. Format is user programmable.
Pin 3
RECEIVE DATA - Data transmitted from the Host Computer to the Series 9000E Scanner/Decoder. Transmission is serial ASCII. Format is user programmable.
Pin 4
DATA SET READY - A signal sent from the Host Computer to the Series 9000E Scanner/Decoder to indicate that it is on-line. 4-3
Page 28
Series 9000E Scanner/Decoder Pin 5 lines.
COMMON GROUND - Ground terminal common to all signal
Pin 6
DATA TERMINAL READY - A signal sent from the Series 9000E Scanner/Decoder to the Host Computer to indicate that it is online.
Pin 7
CLEAR TO SEND - A signal sent from the Host Computer to the Series 9000E Scanner/Decoder as an acknowledgment to the Request to Send signal, and giving permission to send data. Configuration is user programmable.
Pin 8
REQUEST TO SEND - A signal sent from the Series 9000E Scanner/Decoder to the Host Computer indicating that it has data to send. Configuration is user programmable.
RS-422 Connections
Pin 1
PIN
NAME
DESCRIPTION
DIRECTION
1
RXD-
Receive Data -
In
2
TXD+
Transmit Data +
Out
3
N/C
No Connection
4
N/C
No Connection
5
GND
Common Ground
6
N/C
No Connection
7
N/C
No Connection
8
TXD-
Transmit Data -
Out
9
RXD+
Receive Data +
In
RECEIVE DATA (-) - Negative connection for data transmitted from the Host Computer to the Series 9000E Scanner/Decoder.
4-4
Page 29
SIGNAL INTERFACES Pin 2
TRANSMIT DATA (+) - Positive connection for data transmitted from the Series 9000E Scanner/Decoder to the Host Computer. Transmission is serial ASCII. Format is user-programmable.
Pin 5
COMMON GROUND - Ground connection common to all signals.
Pin 8
TRANSMIT DATA (-) - Negative connection for data transmitted from the SERIES 9000E Scanner/Decoder to the Host Computer.
Pin 9
RECEIVE DATA (+) - Positive connection for data transmitted from the Host Computer to the Series 9000E Scanner/Decoder. Transmission is serial ASCII. Format is user-programmable.
RS-485 Connections PIN
NAME
DESCRIPTION
DIRECTION
1
RS-485 (-)
Data -
Bi-directional
2
N/C
No Connection
3
N/C
No Connection
4
N/C
No Connection
5
GND
Common Ground
6
N/C
No Connection
7
N/C
No Connection
8
N/C
No Connection-
9
RS-485 (+)
Data +
Bi-directional
Pin 1
RS-485 (-) - Signal for three wire Party Line configuration.
Pin 5
Common Ground - Ground common to all signals.
Pin 9
RS-485 (+) - Signal for three wire Party Line configuration.
4-5
Page 30
Series 9000E Scanner/Decoder I/O PORT This port is designed to provide status output pulses and accept input signals for gating and push button compare. Output pulses are provided for Good Read, No Read, Good Compare, and No Compare Conditions. Pins 1, 6 and 15 can be used as an alternate method of supplying scanner power. If the scanner is powered using the power connector, these pins may be used as a voltage source to power external hardware such as a gate sensor. Connections are made through a DE-15S connector as shown below.
DE-15S Connector
4-6