Page 11

INTRODUCTION

SYSTEM DESCRIPTION The LazerData Series 9000E Scanner/Decoder offers scanning and decoding functions in a single package measuring only 2.5" wide X 2.5" high X 3.85" long. The durable extruded aluminum housing affords maximum protection for the scanning optics and decoding circuitry. Scanning at speeds from 100 to 1500 scans per second, it is ideal for applications such as high speed packaging machines. The laser diode light source offers the long operating life associated with solid state devices. Systems configuration is accomplished through the use of an ordinary computer terminal and a Series of menu screens assuring that no special programming skills are necessary to setup the unit. The scanner can communicate with peripheral devices using either RS-232, RS-422 or RS-485 protocols. Using an external power supply keeps the scanner size to a minimum and reduces the internal operating temperature.

TECHNICAL SPECIFICATIONS Light Source Type: Output Wavelength:

Safety Class: Operating Life: Scanning Parameters Type: Rate:

Laser Diode 670-680 nm--visible red, 840 nm--infrared or 1330 nm--infrared, depending on model. Class II Greater than 50,000 hours

Rotating polygon, unidirectional scan 500 to 1000 sweeps per second, depending on model. 1500 scan rate available for special applications.

2-1

Page 12

Series 9000E Scanner/Decoder Decoding Capability C11, C39, C93, C128, C49 (2 row numeric only), Codabar, UPCE*, UPCA*, EAN8*, EAN13*, I2/5, Binary, AS10, Pharmacode, ISTR. (* with or without supplemental.) Host Port Hardware Protocols: Software Protocols: Wiring: Baud Rate: Local Port Hardware Protocol: Software Protocol: Wiring: Baud Rate:

I/O Port Inputs: Outputs: Wiring: LED Indicators BI-color LED:

Amber LED:

Power Requirements Input Voltages: Wiring:

RS-232C, RS-422 or RS-485 ACK/NAK, XON/XOFF, LazerData Intermec Mult-idrop, or None. DE9S Connector User Programmable, 300 to 38,400

RS-232C XON/XOFF, None DE9P Connector User Programmable, 300 to 38,400. Set to 9600 at manufacture.

Gate, Push Button Compare Good Read, No Read, Good Compare, No Compare, Digitized Output. DE15S Connector

Good Read-Blinks Green No Read-Blinks Red Not Functional on Infrared Scanners Indicates Laser Emission Not Functional on Infrared Scanners

+5 VDC +5%, 860 mA. +12 VDC +5%, 300 mA. 5-pin keyed connector

2-2

Page 13

INTRODUCTION PRINCIPLES OF OPERATION The LazerData Series 9000E bar code scanner/decoder uses a light beam generated by a laser diode light source to illuminate bar code labels. The laser beam is deflected in a fan shaped pattern across the label. The reflected light of the laser beam, representing the light and dark bars of the coded label, is then collected and focused by a lens onto a photodiode, processed, then converted to a digital signal. The signal is a close approximation of the bar code pattern as shown in Figure 2-1. This signal is then analyzed by a high speed microprocessor. The bars and spaces in the code are converted to the numeric or alphabetic characters represented by the bar code symbol. After the label is decoded, the characters are transmitted via the Host and Local Port to an external device or host computer.

Bar Code and Digital Signal Figure 2-1 In addition to reading the code, the scanner can compare the code that has been read to codes programmed into it's memory and output signals indicating that a comparison has or has not occurred. The scanner can also accept a gate input signal indicating that a code is in position to be read. When the gating input is used, only one data transmission is made for each bar code presented to the scanner. The scanner also outputs separate logic level pulses when Good Read, No Read, Good Compare and No Compare conditions occur.

2-3

Page 14

Series 9000E Scanner/Decoder

2-4

Page 15

INSTALLATION

INTRODUCTION The LazerData Series 9000E Scanner/Decoder is designed for easy installation in many diverse applications and, because of its small size and light weight, can be mounted with common hardware. The user may fabricate a custom mounting bracket or use the mounting holes provided. The scanner can be mounted in any orientation, but label position, and motion relative to the scanner dictate optimum position and distance, as discussed in this section.

UNPACKING AND INSPECTION Upon receipt of the Series 9000E Scanner/Decoder unit, it should be carefully unpacked and inspected. Remove all documentation (packing lists, manuals, etc.) from shipping container. Carefully remove the packing material from around the scanner, and lift the unit from the shipping container. Do not discard packing material. If your scanner ever needs repair, you are requested to return the unit in its original container. Check to ensure all items have been received. Standard package content includes: Series 9000E Scanner/Decoder Local Port Cable (part # 1702076) Host Port Mating Connector (part # Y260020) I/O Port Mating Connector (part # Y259930) Back shells (part # 7651021) Power Connector (Some Models) Power Supply (part # 1902032) Manual (part # 7902033)

3-1

Page 16

Series 9000E Scanner/Decoder Inspect all items received for any visible damage that may have been incurred during shipping. Of particular interest is the glass window at the front of the scanner unit. If any items are missing or damaged, immediately notify the carrier and Customer Administration at PSC Automation, Inc. Call 1-800-843-2700. Maintain all shipping documentation, containers, and packing materials until discrepancies are cleared.

MOUNTING PROVISION The fundamental mounting of the scanner is provided for by eight through holes in the housing designed to accommodate #6 mounting hardware. Mounting brackets may be fabricated by user if deemed necessary. Figure 3-1 illustrates the overall dimensions of the scanning unit as well as the position of the mounting holes relative to the scanning beam location. The installation of the Series 9000E Scanner/Decoder is straight forward and will be successful if some simple guidelines are followed. Install scanner unit in locations that are: Protected from collisions with packages that may be passing close to the scanner. A reasonable operating environment with a temperature between 0 and 50 degrees centigrade (32 and 122 degrees Fahrenheit) and away from extreme heat sources. Not in a high electrical noise area; for example, near large AC motors or solenoids. Away from high vibration areas. Easily accessible for service and adjustment.

3-2

Page 17 read from a scan by OCR; it may hold reading errors

INSTALLATION o - - __ - e| + 4 1.255, ©d S 2.50 OMIT FOR aN |.R. UNITS. LHL |} 2.22 e) OF r (| [d| @) @) |] OMIT FOR wi: Tunas Sin wie IR. UNITS.

Part Number Date of Manufacture Serial Number HN NH

‘This procuct complies wth 21 CFR Subchopier J and 1£C825:1993

Taser Nght when open avoid direct exposure fo beam,

“ly BS: a

0 ol

Dimensions Figure 3-1

3-3

Page 18

Series 9000E Scanner/Decoder

POWER REQUIREMENTS The Series 9000E Scanner/Decoder is powered from a multiple-voltage DC power source. Voltages required are +5 VDC @860 mA. and +12 VDC @ 300 mA. These voltages are supplied to the unit through a keyed 5-pin power connector. The I/O Port is an alternate connection for input power. For connector wiring consult Section 4, Signal Interfaces.

SPECULAR REFLECTION Bar code reading scanners can be blinded by specular reflections from mirror-like surfaces on the bar code label and make it difficult or impossible to obtain an accurate reading. This occurs when code symbols are printed on glossy material or a plastic coating is applied over the code symbol for protection. In general, if the bar code looks shiny to the eye, it should be treated as a specular code. Specular reflection can be eliminated by mounting the scanner at an angle relative to the code. Angles of 10 to 15 degrees are normally used. Do not tilt the scanner in the direction of the sweep, but perpendicular to that direction. Figure 3-2 illustrates proper scanner mounting for bar codes with mirror-like surfaces.

Scanner Mounting for Bar Codes with Mirror-Like Surfaces Figure 3-2 3-4

Page 19

INSTALLATION

MOUNTING ORIENTATION Optimum operation of the bar code scanner demands proper orientation of the scanner relative to the bar code label it is to read. It is not possible to cover all situations so general rules are provided here. The Applications Engineering Group at PSC Automation, Inc. is available to assist in establishing mounting parameters in unusual situations. Call (800) 843-2700 for assistance. The optimum distance from the scanner to the bar code label varies with the printing density of the barcode. Printing density refers to the width of the smallest bar or space in the code symbol. Higher density labels (narrower bars and spaces) must be closer to the scanner to be read, while lower density labels (wider bars and spaces) can be read further away. Figure 3-3 illustrates typical reading distances for several widths of bars and spaces. The closest distance from scanner to code is usually, but not limited to, 2.0 inches. The distances shown are typical and meant to illustrate the performance capabilities of the scanner. If density or bar width information about the code symbol is not known, the optimum operating distance can be determined experimentally. Connect a terminal to the Local Port as outlined in Section 5, Local Programming. Enter the Configuration Menu. Select Page 2, Field Parameters. Select the correct algorithm for the barcode to be used. Return to the Main Menu and select Page 7, Diagnostics. Select Read Percentage Test. Adjust the distance from the scanner to the barcode label while viewing the diagnostics display. Find the distance where the values displayed for #Decodes is the largest. This is the optimum distance for that particular label. For most applications the label will be read reliably at a value of 95 or more decodes. This operating distance will be the center of the operating range for the label. Type CFG <enter> to return to the main menu and turn off diagnostics mode.

3-5

Page 20

Series 9000E Scanner/Decoder

Operating Distance and Beam Sweep Width of Various Bar Sizes Figure 3-3

3-6