Page 47

Output Sequence Overview

Quick Omnidirectional - This is an abbreviated search for bar code features around the center region of an image. This mode quickly reads all symbologies in any orientation. The Quick Omnidirectional mode may miss some off-center symbols, as well as larger Data Matrix and QR Code symbols.

Quick Omnidirectional

Advanced Linear Decoding - Performs quick horizontal linear scans in a center band of the image. This mode is not omnidirectional, but does quickly read linear and stacked bar codes. Advanced Linear Decoding cannot read 2D, OCR, or Postal symbols. This search mode is the default setting for point-and-shoot PDF imagers.

Advanced Linear Decoding

Output Sequence Overview Require Output Sequence When turned off, the bar code data will be output to the host as the Imager decodes it. When turned on, all output data must conform to an edited sequence or the Imager will not transmit the output data to the host device. This selection is unavailable when the Multiple Symbols Selection is turned on. NOTE

Product Reference Guide

3-17

Page 48

Output

Output Sequence Editor This programming selection allows you to program the Imager to output data (when scanning more than one symbol) in whatever order your application requires, regardless of the order in which the bar codes are scanned. Reading the Default Sequence symbol programs the Imager to the Universal values, shown below. These are the defaults. Be certain you want to delete or clear all formats before you read the Default Sequence symbol.

NOTE

To make Output Sequence Editor selections, you’ll need to know the code I.D., code length, and character match(es) your application requires. Use the Alphanumeric symbols from the Programming Chart on page B-5 to read these options.

To Add an Output Sequence 1. Scan the Enter Sequence symbol (see Multiple Symbols on page 322). 2. Code I.D. On the Symbology Chart on page A-1, find the symbology to which you want to apply the output sequence format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart on page B-5. 3. Length Specify what length (up to 9999 characters) of data output will be acceptable for this symbology. Scan the four digit data length from the Programming Chart. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.) When calculating the length, you must count any programmed prefixes, suffixes, or formatted characters as part of the length (unless using 9999). 4. Character Match Sequences From the ASCII Conversion Chart (Code Page 1252) on page A-4, find the Hex value that represents the character(s) you want to match. Use the Programming Chart to read the alphanumeric combination that represents the ASCII characters. (99 is the Universal number, indicating all characters.)

3-18

PowerScan® 7000 2D

Page 49

Output Sequence Overview

5. End Output Sequence Editor Scan F F to enter an Output Sequence for an additional symbology, or Save to save your entries.

Other Programming Selections Discard

This exits without saving any Output Sequence changes.

Output Sequence Examples In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the imager to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below.

Code 93 must be enabled to use this example. NOTE

A - Code 39

B - Code 128

C - Code 93

You would set up the sequence editor with the following command line: SEQBLK62999941FF6A999942FF69999943FF

Product Reference Guide

3-19

Page 50

Output

The breakdown of the command line is shown below: SEQBLK 62 9999 41 FF 6A 9999 42 FF 69 9999 43 FF sequence editor start command code identifier for Code 39 code length that must match for Code 39, 9999 = all lengths start character match for Code 39, 41h = “A” termination string for first code code identifier for Code 128 code length that must match for Code 128, 9999 = all lengths start character match for Code 128, 42h = “B” termination string for second code code identifier for Code 93 code length that must match for Code 93, 9999 = all lengths start character match for Code 93, 43h = “C” termination string for third code

To program the previous example using specific lengths, you would have to count any programmed prefixes, suffixes, or formatted characters as part of the length. If you use the example on page 3-19, but assume a <CR> suffix and specific code lengths, you would use the following command line: SEQBLK62001141FF6A001242FF69001143FF

The breakdown of the command line is shown below: SEQBLK 62 0011 41 FF 6A 0012 42 FF 69 0011 43 FF

3-20 sequence editor start command code identifier for Code 39 Code 39 code length (9) plus CR suffix (2) = 11 start character match for Code 39, 41h = “A” termination string for first code code identifier for Code 128 Code 128 code length (10) plus CR suffix (2) = 12 start character match for Code 128, 42h = “B” termination string for second code code identifier for Code 93 Code 93 code length (9) plus CR suffix (2) = 11 start character match for Code 93, 43h = “C” termination string for third code

PowerScan® 7000 2D

Page 51

Output Sequence Overview

Output Sequence Editor

Enter Sequence Default Sequence

Require Output Sequence When an output sequence is Required, all output data must conform to an edited sequence or the imager will not transmit the output data to the host device. When it’s On/Not Required, the imager will attempt to get the output data to conform to an edited sequence, but if it cannot, the imager transmits all output data to the host device as is. When the output sequence is Off, the bar code data is output to the host as the imager decodes it. This selection is unavailable when the Multiple Symbols Selection is turned on. NOTE

Required On/Not Required *Off

Product Reference Guide

3-21

Page 52

Output

Multiple Symbols This feature does not work when the Imager is in Low Power mode. NOTE

When this programming selection is turned On, it allows you to read multiple symbols with a single pull of the Imager’s trigger. If you press and hold the trigger, aiming the Imager at a series of symbols, it reads unique symbols once, beeping (if turned on) for each read. The imager attempts to find and decode new symbols as long as the trigger is pulled. When this programming selection is turned Off, the Imager will only read the symbol closest to the aiming beam.

On * Off

No Read With No Read turned On, the Imager notifies you if a code cannot be read. If using a PowerView Scan Data Window, an “NR” appears when a code cannot be read. If No Read is turned Off, the “NR” will not appear.

On * Off

If you want a different notation than “NR,” for example, “Error,” or “Bad Code,” you can edit the output message using the Data Formatter on page 5-5. The hex code for the No Read symbol is 9C.

3-22

PowerScan® 7000 2D

Page 53

Print Weight

Print Weight Print Weight is used to adjust the way the imager reads Matrix symbols. If a imager will be seeing consistently heavily printed matrix symbols, then a print weight of 6 may improve the reading performance. For consistently light printing, a print weight of 2 may help. After scanning the Set Print Weight bar code, set the print weight (from 1-7) by scanning digits from the Programming Chart on page B-5, then scanning Save. Default = 4.

Set Print Weight * Default

Video Reverse Video Reverse is used to allow the imager to read bar codes that are inverted. The “Off ” bar code below is an example of this type of bar code. If additional menuing is required, Video Reverse must be disabled to read the menu bar codes and then re-enabled after menuing is completed. Images downloaded from the unit will not be reversed. This is a setting for decoding only. NOTE

On

* Off

Product Reference Guide

3-23

Page 54

Output

Working Orientation Some bar codes are direction-sensitive. For example, KIX codes and OCR can misread when scanned sideways or upside down. Use the working orientation settings if your direction-sensitive codes will not usually be presented upright to the scanner. Default = Upright. Upright:

Rotate Clockwise 90°:

Upside Down:

Rotate Counterclockwise 90°:

* Upright Rotate Clockwise 90° Upside Down Rotate Counterclockwise 90°

3-24

PowerScan® 7000 2D