Page 55

Chapter 4

Data Editing

NOTE

For Universal Keyboard Wedge (UKBW) interfaces do not use this section. Refer instead to the Universal Keyboard Wedge Programming Guide which is available for download from the website listed on the back cover of this manual.

Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string. Prefix and Suffix characters are data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. The following illustration shows the breakdown of a message string:

Prefix 1-11 alpha numeric characters

Scanned Data variable length

Product Reference Guide

Suffix 1-11 alpha numeric characters

4-1

Page 56

Data Editing

Points to Keep In Mind •

It is not necessary to build a message string. The selections in this chapter are only used if you wish to alter the default settings. Default prefix = None. Default suffix = None.

•

A prefix or suffix may be added or cleared from one symbology or all symbologies.

•

You can add any prefix or suffix from the ASCII Conversion Chart (Code Page 1252) on page A-4, plus Code I.D. and AIM I.D.

•

You can string together several entries for several symbologies at one time.

•

Enter prefixes and suffixes in the order in which you want them to appear on the output.

4-2

PowerScan® 7000 2D

Page 57

Prefix/Suffix Overview

To Add a Prefix or Suffix: Step 1. Scan the Add Prefix or Add Suffix symbol (page 4-5). Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Symbology Chart on page A-1) for the symbology to which you want to apply the prefix or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”.

Step 3. Scan the 2 hex digits from the Programming Chart on page B-5 of this manual or scan 9, 9 for all symbologies.

Step 4. Determine the hex value from the ASCII Conversion Chart (Code Page 1252) on page A-4, for the prefix or suffix you wish to enter.

Step 5. Scan the 2 digit hex value from the Programming Chart on page B-5 of this manual.

Step 6. Repeat Steps 4 and 5 for every prefix or suffix character. Step 7. To add the Code I.D., scan 5, C, 8, 0. To add AIM I.D., scan 5, C, 8, 1. To add a backslash (\), scan 5, C, 5, C. To add a backslash (\) as in Step 7, you must scan 5C twice – once to create the leading backslash and then to create the backslash itself. NOTE

Step 8. Scan Save to exit and save, or scan Discard to exit without saving.

Repeat Steps 1-6 to add a prefix or suffix for another symbology.

Product Reference Guide

4-3

Page 58

Data Editing

Example: Add a Suffix to a specific symbology To send a CR (carriage return)Suffix for UPC only: Step 1. Scan Add Suffix. Step 2. Determine the 2 digit hex value from the Symbology Chart (included in ASCII Conversion Chart (Code Page 1252) on page A-4) for UPC.

Step 3. Scan 6, 3 from the Programming Chart on page B-5 of this manual. Step 4. Determine the hex value from the ASCII Conversion Chart (Code Page 1252) on page A-4, for the CR (carriage return).

Step 5. Scan 0, D from the Programming Chart on page B-5 of this manual. Step 6. Scan Save, or scan Discard to exit without saving.

To Clear One or All Prefixes or Suffixes: You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. When you Clear One Prefix (Suffix), the specific character you select is deleted from the symbology you want. When you Clear All Prefixes (Suffixes), all the prefixes or suffixes for a symbology are deleted. Step 1. Scan the Clear One Prefix or Clear One Suffix symbol. Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in ASCII Conversion Chart (Code Page 1252) on page A-4) for the symbology from which you want to clear the prefix or suffix.

Step 3. Scan the 2 digit hex value from the Programming Chart on page B-5 of this manual or scan 9, 9 for all symbologies.

Your change is automatically saved.

To Add a Carriage Return Suffix to all Symbologies Scan the following bar code if you wish to add a carriage return suffix to all symbologies at once. This action first clears all current suffixes, then programs a carriage return suffix for all symbologies.

Add CR Suffix All Symbologies

4-4

PowerScan® 7000 2D

Page 59

Prefix/Suffix Overview

Prefix Selections

Add Prefix Clear One Prefix Clear All Prefixes

Suffix Selections

Add Suffix Clear One Suffix Clear All Suffixes

Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the imager transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys on page 9-3. Default = Enable.

* Enable Disable

Product Reference Guide

4-5

Page 60

Data Editing

Intercharacter, Interfunction, and Intermessage Delays Some terminals drop information (characters) if data comes through too quickly. Intercharacter, interfunction, and intermessage delays slow the transmission of data, increasing data integrity. Each delay is composed of a 5 millisecond step. You can program up to 99 steps (of 5 ms each) for a range of 0-495 ms.

Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed between the transmission of each character of scanned data. Scan the Intercharacter Delay bar code below, then scan the number of milliseconds and the SAVE bar code using the Programming Chart on page B-5 of this manual. Prefix

Scanned Data 1

2

3

4

Suffix 5

Intercharacter Delay

Intercharacter Delay

To remove this delay, scan the Intercharacter Delay bar code, then set the number of steps to 0. Scan the SAVE bar code using the Programming Chart on page B-5 of this manual. Intercharacter delays are not supported in USB serial emulation. NOTE

4-6

PowerScan® 7000 2D

Page 61

Intercharacter, Interfunction, and Intermessage Delays

User Specified Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed after the transmission of a particular character of scanned data. Scan the Delay Length bar code below, then scan the number of milliseconds and the SAVE bar code using the Programming Chart on page B-5of this manual. Next, scan the Character to Trigger Delay bar code, then the 2-digit hex value for the ASCII character that will trigger the delay ASCII Conversion Chart (Code Page 1252) on page A-4.

Delay Length Character to Trigger Delay

To remove this delay, scan the Delay Length bar code, and set the number of steps to 0. Scan the SAVE bar code using the Programming Chart on page B-5 of this manual.

Interfunction Delay An interfunction delay of up to 495 milliseconds may be placed between the transmission of each segment of the message string. Scan the Interfunction Delay bar code below, then scan the number of milliseconds and the SAVE bar code using the Programming Chart on page B-5 of this manual. Prefix STX

1

Scanned Data HT

2 3 4 5

Suffix CR

LF

Interfunction Delays

Interfunction Delay

To remove this delay, scan the Interfunction Delay bar code, then set the number of steps to 0. Scan the SAVE bar code using the Programming Chart on page B-5 of this manual. Product Reference Guide

4-7

Page 62

Data Editing

Intermessage Delay An intermessage delay of up to 495 milliseconds may be placed between each scan transmission. Scan the Intermessage Delay bar code below, then scan the number of milliseconds and the SAVE bar code using the Programming Chart on page B-5 of this manual. 1st Scan Transmission 2nd Scan Transmission Intermessage Delay

Intermessage Delay

To remove this delay, scan the Intermessage Delay bar code, then set the number of steps to 0. Scan the SAVE bar code using the Programming Chart on page B-5 of this manual.