Page 39

Double Read Timeout

Scan the Hands Free Time-Out bar code, then scan the time-out duration (from 0-300,000 milliseconds) from the Programming Chart on page B-5, and Save. Default = 5,000 ms.

Hands Free Time-Out

Double Read Timeout This sets the time period before the imager can read the same bar code a second time. Setting a reread delay protects against accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads at POS (point of sale). Use shorter delays in applications where repetitive bar code scanning is required. Default = Medium. Reread Delay only works when in Presentation Mode (see Presentation Mode on page 3-7).

Short (500 ms) * Medium (750 ms) Long (1000 ms) Extra Long (2000 ms)

User-Specified Double Read Timeout If you want to set your own length for the reread delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the Programming Chart on page B-5, then scanning Save.

User-Specified Double Read Timeout

Product Reference Guide

3-9

Page 40

Output

LED Power Level This selection allows you to adjust LED and aimer brightness. Off is used when no illumination is needed. Low is used if low illumination is sufficient. High (the default) is the brightest setting. If you have an aimer delay programmed (see Aimer Delay on page 3-12), the aimer will be at 100% power during the delay, regardless of the LED Power Level.

NOTE

If you scan the Off bar code, both the aimer and illumination lights turn off, making it impossible to scan bar codes in low light. To turn the LED Power Level back on, move to a brightly lit area and scan either the Low or the High bar code below.

Off Low (50%) * High (100%)

3-10

PowerScan® 7000 2D

Page 41

Illumination Lights

Illumination Lights If you want the illumination lights on while reading a bar code, scan the Lights On bar code, below. However, if you want to turn just the lights off, scan the Lights Off bar code. This setting does not affect the aimer light. The aiming light can be set using Aimer Mode (see Aimer Modes on page 3-13). NOTE

* Lights On Lights Off

Imager Time-Out Imager Time-Out powers down the imager after the unit has been idle for the specified time. To prevent the imager from powering down, set this time-out to 0. Scan the bar code below, then set the time-out by scanning digits (from 0 - 999,999 ms) from the Programming Chart on page B-5, then scanning Save. Default = 120,000 ms.

Imager Time-Out

Product Reference Guide

3-11

Page 42

Output

Aimer Delay The aimer delay allows a delay time for the operator to aim the imager before the picture is taken. Use these codes to set the time between when the trigger is pulled and when the picture is taken. During the delay time, the aiming light will appear, but the LEDs won’t turn on until the delay time is over.

200 milliseconds 400 milliseconds * Off (no delay)

User-Specified Aimer Delay If you want to set your own length for the duration of the delay, scan the bar code below, then set the time-out by scanning digits (0 - 4,000 ms) from the Programming Chart on page B-5 of this manual, then scan Save.

Delay Duration

3-12

PowerScan® 7000 2D

Page 43

Aimer Modes

Aimer Modes This feature allows you to select from the three options listed below:

Aimer Mode Off Aimer Mode is disabled.

Interlaced Mode In Interlaced Mode, the illumination and aiming timing is automatically synchronized to the imager exposure period by the Optics Module. The module turns illumination on while the image is being exposed, and it turns the aiming off at all other times. Interlaced Mode provides the lowest overall current draw and is recommended for most applications. It also provides the brightest aimer in most applications. Imager software automatically maintains an approximate 25% aimer duty cycle, even when the imager exposure time is at its maximum in dark operating environments.

NOTE

When in Interlaced Mode, the illumination level will dynamically change with the degree of ambient light and reflection from the bar code being scanned.

Concurrent Mode Concurrent Mode is provided for backwards compatibility with previous models, and is not recommended for most applications. NOTE

In Concurrent Mode, the illumination LEDs are on continuously, while the aimer LEDs turn off during the imager exposure period, and on while the imager is not exposing. This Mode is used to eliminate any flicker of the illumination LEDs that may be objectionable to the user. In Concurrent Mode, the illumination LED current is reduced in comparison to Interlaced Mode with regard to limiting engine peak current. Imager software automatically maintains an approximate 25% aimer Product Reference Guide

3-13

Page 44

Output duty cycle, even when the imager exposure time is at its maximum in dark operating environments. Concurrent mode provides the brightest appearance of the illumination LEDs of any of the imager operating modes. This mode may be useful for applications when an operator is using the illumination LEDs for aiming, such as in fixed mount, kiosk, or auto trigger applications.

Off * Concurrent

Interlaced

Centering Use Centering to narrow the imager’s field of view to make sure the imager reads only those bar codes intended by the user. For instance, if multiple codes are placed closely together, centering will insure that only the desired codes are read. (Centering can be used in conjunction with Aimer Delay on page 3-12, for the most error-free operation in applications where multiple codes are spaced closely together. Using the Aimer Delay and Centering features, the imager can emulate the operation of older systems, such as linear laser bar code imagers.) Figure 3-1. Centering Example Bar Code 1

Bar Code 2

3-14

PowerScan® 7000 2D

Page 45

Centering

In the example in Figure 3-1, the gray area is the full imager field of view and the white area is the centering window. Bar Code 1 will not be read, while Bar Code 2 will be.The default centering window is a 128x96 pixel area in the center of the imager’s field of view. The following diagram illustrates the default top, bottom, left, and right pixel positions, measured from the top and the left side of the imager’s field of view, which is 640 by 480 pixels. 40%

60%

100%

0

Top

40%

Bottom

Default Center

60%

Left Right 100%

If a bar code is not within the predefined window, it will not be decoded or output by the imager. If centering is turned on by scanning Centering On, the imager only reads codes that intersect the centering window you specify using the Top, Bottom, Left, or Right bar codes.

Product Reference Guide

3-15

Page 46

Output

Scan Centering On, then scan one of the following bar codes to change the top, bottom, left, or right of the centering window. Then scan the percent you want to shift the centering window using digits on the Programming Chart on page B-5. Scan Save. Default Centering = 40% for Top and Left, 60% for Bottom and Right.

Centering On * Centering Off Top of Centering Window Bottom of Centering Window Left of Centering Window Right of Centering Window

Decode Search Mode There are three selectable decode (scanning) modes: Full Omnidirectional - Searches for bar code features beginning at the center of an image, and searches to the image’s limits. This mode reads all symbologies (including OCR), in any orientation. The Full Omnidirectional search is very thorough which may slow performance time.

This search mode is the default setting. NOTE

Full Omnidirectional

3-16

PowerScan® 7000 2D