Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 23

PowerScan 7000 2D Imager Product Reference Guide: Output, pages 31 to 38

Pages 31 to 38 of 204, from PowerScan 7000 2D Imager Product Reference Guide

The original document is the PDF (3.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic 7000 (P70) and PSC 7000 (P70)

Page 31

Chapter 3

Output Image VGA You can set the image size to a VGA resolution, if necessary, to accommodate older applications that require a smaller image size. When Image VGA is set to On, the resultant image is 640x480 pixels. When Image VGA is Off, your image is 752x480 pixels. Default = Off.

* Off On

Good Read Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = On.

* On Off

Product Reference Guide

3-1

Page 32

Output

Beeper Volume – Good Read The beeper volume codes modify the volume of the beep the imager emits on a good read. Default = Medium.

Low * Medium High Off

Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the imager emits on a good read. Default = Medium.

Low (1400 Hz)

Medium (2800 Hz)

* High (3100 Hz)

3-2

PowerScan® 7000 2D

Page 33

Good Read Indicators

Beeper Duration – Good Read The beeper duration codes modify the length of the beep the imager emits on a good read. Default = Normal.

* Normal Beep Short Beep

LED – Good Read The LED indicator can be programmed On or Off in response to a good read. Default = On.

* On Off

Number of Beeps – Good Read The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read. For example, if you program this option to have five beeps, there will be five beeps and five LED flashes in response to a good read. The beeps and LED flashes are in sync with one another. To change the number of beeps, scan the bar code below and then scan a digit (1-9) bar code and the Save bar code on the Programming Chart on page B-5 of this manual. Default = One.

Number of Pulses

Product Reference Guide

3-3

Page 34

Output

Good Read Delay This sets the minimum amount of time before the imager can read another bar code. Default = No Delay.

* No Delay Short Delay (500 ms)

Medium Delay (1,000 ms) Long Delay (1,500 ms)

User-Specified Good Read Delay If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the Programming Chart on page B-5, then scanning Save.

User-Specified Good Read Delay

Trigger Modes Manual/Serial Trigger You can activate the imager either by pressing the trigger, or using a serial trigger command (see Trigger Commands on page 10-5). When in manual trigger mode, the imager scans until a bar code is read, or until the trigger is released.

3-4

PowerScan® 7000 2D

Page 35

Trigger Modes

When in serial mode, the imager scans until a bar code has been read or until the deactivate command is sent. In serial mode, the imager can also be set to turn itself off after a specified time has elapsed (see Read TimeOut, which follows).

* Manual/Serial Trigger

Read Time-Out Use this selection to set a time-out (in milliseconds) of the imager’s trigger when using serial commands to trigger the imager, or if the imager is in manual trigger mode. Once the imager has timed out, you can activate the imager either by pressing the trigger or using a serial trigger command. After scanning the Read Time-Out bar code, set the time-out duration (from 0-300,000 milliseconds) by scanning digits from the Programming Chart on page B-5, then scanning Save. Default = 0 (infinite, or no time-out).

Read Time-Out

Manual Trigger, Low Power The imager powers down until the trigger is pulled. When the trigger is pulled, the imager powers up and operates until there is no triggering for the time set with the Low Power Time-Out bar code below. There is a delay of up to one second in operation when the imager is first triggered, but there is no delay when operating in low power time-out mode.

Manual Trigger, Low Power

Low Power Time-Out Timer Scan the Low Power Time-Out bar code to change the time-out duration (in seconds). Then scan the time-out duration (from 0-300 seconds) from the Programming Chart on page B-5, and Save. Default = 120 seconds.

Product Reference Guide

3-5

Page 36

Output

If the unit remains idle during the low power time-out interval, the unit goes into low power mode. Whenever the trigger is enabled, the low power time-out timer is reset.

Low Power Time-Out

This time-out does not begin until the imager time-out setting has expired. NOTE

3-6

PowerScan® 7000 2D

Page 37

Scan Stand Mode

Scan Stand Mode When a unit is in Scan Stand mode, it remains idle as long as it sees the Scan Stand symbol. (See Scan Stand Symbol that follows.) When a different code is presented, the Imager is triggered to read the new code. Note:The imager automatically adjusts the illumination LEDs to the lowest light level possible to maintain a good lock on the Scan Stand symbol. When a symbol is presented, the imager’s light levels adjust to the saved setting (see LED Power Level on page 3-10).

Scan Stand Mode

Scan Stand Symbol When a unit is in Scan Stand mode, the LEDs shine at the Scan Stand symbol on the base of the stand which tells it to remain idle. When the Scan Stand symbol is covered, the imager turns the LEDs on at the configured power level (Default High) and attempts to find and decode bar codes in its field of view.

Scan Stand Symbol

Presentation Mode This programs the imager to work in Presentation Mode.

Presentation Mode

Product Reference Guide

3-7

Page 38

Output

Presentation LED Timer When an imager is in presentation mode, the LEDs turn off immediately after a bar code is decoded. The imager can be programmed to continue scanning and to keep the LEDs on for a short time after by scanning the LEDs On bar code below. Default = LEDs On.

* LEDs On LEDs Off

Presentation Sensitivity Presentation Sensitivity is a numeric range that increases or decreases the imager's reaction time to bar code presentation. To set the sensitivity, scan the Sensitivity bar code, then scan the degree of sensitivity (from 020) from the Programming Chart on page B-5, and Save. 0 is the most sensitive setting, and 20 is the least sensitive. Default = 1.

Sensitivity

Hands Free Time-Out The Scan Stand and Presentation Modes are referred to as “hands free” modes. If the imager’s trigger is pulled when using a hands free mode, the imager changes to manual trigger mode. You can set the time the imager should remain in manual trigger mode by setting the Hands Free Time-Out. Once the time-out value is reached, (if there have been no further trigger pulls) the imager reverts to the original hands free mode.

3-8

PowerScan® 7000 2D