Page 27

HF

External Trigger(-)

General Parameters Intercharacter Delay Certain terminals and computers require an intercharacter delay to simulate the effects of keystroke delays. Choosing an intercharacter delay causes the characters to be sent at the slower speed required by the device to which you are interfacing. GA

No Intercharacter Delay

NOTE

GB

To set Intercharacter Delay to other then zero, scan the label below and then scan two separate digits from the Digit Selection page (99 maximum).

Intercharacter Delay = XXMEC

Intercharacter delay cannot exceed 99 milliseconds. NOTE Interlabel delay allows user to program a delay between transmitted labels.

GC

No interlabel delay *@

GD

Set interlabel delay 0-9.9 seconds

06656

21

Page 28

Transmission Mode Full Duplex or Half Duplex

This section pertains only to models with a Liquid Crystal Display (LCD) NOTE Transmission mode selects either full or half duplex operation regardless of interface. In the half duplex mode, the decoded message is sent simultaneously to the display and to the host computer. In the full duplex mode, the message is sent to the host computer. In send mode, the host always has the capability to send a message directly to the LCD. The advantage of the full duplex mode is that the display shows the message received by the host. In the half duplex mode you can see that the message has been sent but there is no confirmation that it was received. The disadvantage of the full duplex mode is simply that the host computer must be programmed to relay the message back to the scanner.

NA

Transmission Mode = Full Duplex

NB

Transmission Mode = Half Duplex *#

For models which do not have an LCD, parameter selections NA and NB have no effect. NOTE

System Status To examine the configuration of your system, scan the appropriate option. When Option ZB is scanned, a list of currently programmed parameters is sent to the display device. Scanning ZB may interfere with your terminal software, depending on your application.

22

User’s / Programming Guide

Page 29

ZB

Display Configuration

When Option ZC is scanned, the program version followed by carriage return-line feed characters (CR-LF) is sent in the format <software name>SP<###> (WDHB 3.86, for example).

ZC

Transmit Version Number

Power Consumption You may choose one of two Power Consumption modes. Option @A supplies full power to the scanner at all times; Option @B allows the unit to revert to a standby mode after a successful read. This mode is a power conservation feature. @A

Enable Continuous@ Full Power

@B

Enable Standby *#

Laser Redundancy For a successful decode to occur when Laser Redundancy is enabled, two laser scans of the bar code must match. Because the laser scans a label many times a second, you will notice little or no change in the speed of the decode. Laser redundancy can be used to enhance the security of the bar code reader. BC

Disable Laser Redundancy *#@

BD

Enable 2 Times Laser Redundancy

06656

23

Page 30

BE

Enable 4 Times Laser Redundancy

Laser Timeout The scan beam will activate in response to a trigger pull. The beam will automatically deactivate after a label is decoded. If a label is not decoded., the scan beam will timeout and deactivate after several seconds. Scan the following labels to control the length of the timeout.

BH

Set Scan Beam *#@ Timeout to 6 Seconds

BI

Set Scan Beam Timeout to 4 Seconds

BJ

Set Scan Beam Timeout to 2 Seconds

BO

Set Scan Beam Timeout to 1 Second

BW

Set Scan Beam Timeout to ½ Second

Beeper Operation Scan one of the options below to modify beeper operation. AA

Beeper Off

AB

Beeper On; Volume Low

24

User’s / Programming Guide