The text of a manual · part 4 of 12
User's / Programming Guide, Handheld Laser Bar Code Scanners, Keyboard Wedge / Wand Emulation Interface: Parameters Selection Guidelines
Pages 17 to 26 of 84, from User's / Programming Guide, Handheld Laser Bar Code Scanners, Keyboard Wedge / Wand Emulation Interface
The original document is the PDF (680 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the PSC 5381
Page 17
Parameters Selection Guidelines Three basic steps must be followed when selecting parameters for your scanner. 1.
Review this manual to be sure you understand the terminology.
2.
Review the requirements of your host system, with a technical expert from your company, if necessary. This will enable you to determine if any of the factory default settings must be altered.
3.
Enable or disable the relevant parameters by scanning the appropriate menus. This operation is described in more detail in the following example.
Examples Assume that the beeper volume is too loud at its default setting. To change the beeper volume from its default value of loud to a setting of low, locate the beeper volume bar code menu in the General Parameters section. Then scan the label to the left of Beeper On, Volume Low. The correct label is reproduced below. AB
Beeper On; Volume Low
NOTE
When enabling or disabling a parameter, be sure the scanner beam illuminates only one bar code symbol at a time. The layout of this manual minimizes accidental multiple-label scanning.
A successful scan is indicated by two short-high beeps. An unsuccessful scan produces no beeps and requires you to rescan the Beeper On; Volume Low bar code. Most parameters are modified in this way, and you may resume normal bar code scanning when no further modifications are desired. Some parameters require multiple scans to modify a setting; for example, Intercharacter Delay. If you wish to set this parameter to 5 milliseconds (msec.):
06656
11
Page 18
1.
Scan the bar code beside Intercharacter Delay = XX and listen for one short-high beep.
2.
After the beep, scan the bar code beside 0 on the Digit Selection page and listen for one short-high beep.
3.
Still at the Digit Selection page, scan the bar code for 5 (the last argument in the command) and listen for two short beeps.
Your PSC scanner does not have a distinct programming mode. Instead, it automatically recognizes and reacts to the labels you scan. If, for example, you scan INTERCHARACTER DELAY = XX and then scan a normal data label, a normal tone is emitted in response to the data label, and the programming command is ignored. No special exit code is required to resume normal operations.
12
User’s / Programming Guide
Page 19
Serial Communication Reset Default To program the communication mode for serial asynchronous communication, scan the following label:
CA
Select Serial Output
Baud Rate There are seven standard serial communication baud rates to select from. Your scanner and the serial host computer must be set to the same baud rate. Select the correct rate. DA
Baud Rate = 300 Baud
DB
Baud Rate = 600 Baud
DC
Baud Rate = 1200 Baud
DD
Baud Rate = 2400 Baud
DE
Baud Rate = 4800 Baud
DF
Baud Rate = 9600 Baud *
DG
Baud Rate = 19200 Baud
06656
13
Page 20
Data Transmission Serial transmission data is composed of three of four different elements, depending upon host system requirements. These elements are the START bit, DATA bits (7 or 8 bits), OPTIONAL PARITY bits, and STOP bit (s) (1 or 2 bits). The PARITY bit is used for error detection (e.g., data altered in transmission), but is not required by all systems. A parity bit, if required, will be in one of the following four formats: If your system requires a WORD length of 7 bits, one or two STOP bits, and a PARITY check, select the appropriate option from Table 1.
Table 1. 7 Bit Options Data
Stop Bits
7
1
Odd
ED
7
1
Even
EC
7
1
Mark
EB
7
1
Space
EA*
7
2
Odd
EH
7
2
Even
EG
14
Parity
Option
User’s / Programming Guide
Page 21
Table 1. 7 Bit Options Data
Stop Bits
7
2
Mark
EF
7
2
Space
EE
Parity
Option
If your system requires a WORD length of 8 bits, 1 or 2 STOP bits, and PARITY check, select the appropriate option from the table below:
Table 2. 8 Bit Options Data
Stop Bits
8
1
Odd
EL
8
1
Even
EK
8
1
Mark
EJ
8
1
Space
EI
06656
Parity
Option
15
Page 22
If your system requires a WORD length of 8 bits and 1 or 2 STOP bits, but no PARITY, select the option below:
Table 3. 8 Bit, No Parity 8
1
8
2
None
EM
EN
PARITY check is not possible with this combination of STOP bits and WORD length. Some receiving equipment requires inverted serial communication signals.
CD
Inverted Serial Communications
Communications Protocol XON/XOFF Protocol controls data flow between your PSC scanner and a serial host computer. If Protocol = XON/XOFF is selected, the scanner recognizes the ASCII XON/XOFF characters. The host may then stop transmission with XOFF and resume with XON. Controlled data flow is achieved between devices when the receiving device sends ASCII XON/XOFF codes to the transmitting device. In other words, when the receiving device is unable to accept data, it sends on XOFF code to inform the host to temporarily suspend data transmission. When the receiving device “catches up,” it sends an XON code to inform the host that it is again ready to accept data. An advantage of this protocol is that additional hardware is not required for implementation; only transmit, receive, and signal ground are required.
16
User’s / Programming Guide
Page 23
CTS Like XON/XOFF protocol, CTS protocol is a mechanism used to control data flow out. The CTS input is used to inform the scanner that the host terminal is ready to accept scanned data. When CTS (+) protocol is selected, the scanner waits for a low level on its CTS input before transmitting data. When CTS (-) is selected, the signal polarities are reversed and a high level indicates data may be transmitted. The CTS protocol may be programmed independently of the RTS protocol; however, the signal polarities must be the same. You may not select CTS (+) and RTS (-). RTS The RTS output from the scanner may be programmed to operate in one of three different modes. In the default mode RTS signals when the scanner is ready to receive commands or data. In the second mode, RTS is in a fixed state. In the third mode, RTS signals when the scanner has data to transmit. The RTS modes are independent of the CTS protocol. However, you must select the same active state for RTS as for CTS. You may not select CTS (-) and RTS fixed low. If CTS (-) is selected, then the active state for RTS will be high. The specified levels are at the modular connector and are inverted when using an RS232 converter pod. NOTE
HA
CTS Protocol = None* RTS low indicates scanner ready to receive data
HB
Protocol = XON/XOFF
HC
Protocol = CTS (-)
06656
17
Page 24
HD
Protocol = CTS (+)
HG
RTS always low
HH
RTS always high
HI
RTS high indicates scanner ready to receive data
HJ
RTS low indicates scanner has data to transmit
HK
RTS high indicates scanner has data to transmit
Another flow control option is available. If enabled, the stop/go protocol disables the trigger after every successful scan. The trigger is then re-enabled with a serial ‘BG’ command in format <STX><ESC>BG<ETX>. BS
Disable Stop/Go Protocol*
BT
Enable Stop/Go Protocol
18
User’s / Programming Guide
Page 25
Label Buffering The user may select one of three levels of serial buffering. With Full Buffering (the default) selected, the scanner will place all scanned labels into a buffer for transmission. This allows the operator to continue scanning even though the previous label may not have been transmitted yet. Scanning will continue normally until the buffer is full, then scanning will stop. Scanning will continue when enough space is available for the current label. When No Buffering is selected then scanning will be stopped until the current label is completely transmitted. When One Label Buffering is selected the scanner will allow the operator to scan one more label in addition to the label already in the transmit buffer. In other words, one label may be scanned beyond the label being transmitted. NE
Full Buffering
NF
No Buffering
NG
One Label Buffering
No Read Option The scanner can be programmed to send a no read message (‘NR’) upon a scan that does not result in a good read. NX
Enable No Read
NY
Disable No Read *
06656
19
Page 26
Menu Commands Parameter Messages In serial mode, most menu commands when scanned will provide a confirmation message to the host along with the ACK. This feature can be enabled or disabled.
BA
Enable Parameter Messages *
BB
Disable Parameter Messages
External Trigger Operation External trigger operation enables an external device to control scanning. External trigger is controlled by applying an external trigger signal to the CTS input (with external triggering enabled). When active, this signal causes scanning to begin just as if the scanner’s trigger were depressed. Scanning continue until a label is decoded or the external trigger signal is deactivated. In the event of a decode, the trigger signal must be deactivated for a minimum of 50 milliseconds before another scan can be attempted (“tying” the trigger signal active does not cause continuous scanning and decoding). When EXTERNAL TRIGGER(+) is scanned, scanning begins when a high level input is applied to the CTS input. Conversely, when EXTERNAL TRIGGER(-) is scanned, scanning begins when a low level is applied to CTS. When CTS is not connected, it is treated as if a high level is applied. The voltage levels given are at the modular connector. If an RS232 converter pod is used, then the levels are inverted.
HA
Disable External Trigger#*@
HE
External Trigger(+)
20
User’s / Programming Guide