Page 77
Application Selector
Command
Description
Delay
Enter a delay duration in seconds in the combo box. This option delays auto start of application(s) to allow drivers to load prior to starting applications
OK
Select/tap the OK button to add/save changes.
X
Select/tap the X button to cancel the creation of this entry.
From the Add Application dialog, the administrator can configure and/or add/ change an a new application entry in the list.
Application Selector The administrator can choose for the user to have access to the desktop or not. The Application Selector can replace the desktop and limit the user to the specified list of applications. Figure B-10. Application Selector
The user can select/tap the desired application. The administrator can customize this list as shown in Application Selector (AppSelect Tab) on page 10.
Product Reference Guide
B-13
Page 78
Falcon® Desktop Utility for Windows®CE. NET
Application Switcher User Interface The application switcher provides the same functionality as the standard windows Alt+Tab function. This allows the user to cycle through the various open applications. The <ESC> key can be used to close the Application Switcher.
The application switcher is activated via an assigned Action key specified in the Hot Key tab. (Refer to Setting Hot Keys (HKeys Tab) on page 5.) When the assigned Hot Key is pressed, the dialog shown to the right will be displayed. During this time, the user can press the arrow keys or the assigned Hot Key to select the application they wish to switch to. When the Enter/Return key is pressed or when an application is tapped with the stylus, the highlighted application will open and the application switcher will close.
B-14
® Falcon® 4220 Windows CE PDA
Page 79
Appendix C Accessories & Peripherals Overview This appendix covers the following accessories and peripherals: •
"Using the Car Charger/Adapter" on page C-1.
•
"Installing Compact Flash Type Peripherals" on page C-2.
•
"Using the Earphones / Microphone" on page C-4.
•
"Installing the Handstrap" on page C-5.
•
"Using a High Capacity Battery" on page C-6.
•
"Holster" on page C-7.
•
"Using SD Memory Card" on page C-9.
•
"Using the USB / Serial Connection" on page C-10.
Customize your PDA with the many peripherals, data storage devices, battery packs and other accessories available for the Falcon 4220.
Using the Battery Charger Refer to the Falcon 4220 Quick Reference Guide for more information on the Battery Chargers.
Using the Car Charger/Adapter One of the Accessories available for the PDA is a car adapter/charger. Insert the small end of the adapter into the PDA and the larger end into your vehicle’s power source (cigarette lighter-type socket). Table C-1. Car Adapter Electrical Specifications Parameters Input Voltage
Product Reference Guide
Test Conditions
Min.
Max
Unit of Measure
Off Load
10
30
V
C-1
Page 80
Accessories & Peripherals
Parameters
Input Current
Test Conditions
Min.
Max
Unit of Measure
Vin = 12V, Off Load Quiescent Current
10
- mA
Vin = 12/33, RL = 2.5 Inrush Current
Vin = 10.8~33V
Input Voltage Surge (Fuse Protected)
30V < Vin ≤ 40V
Output Voltage Output Current
0.8 (30V) 1.2 (10.8V)
A
3
A
-
-
-
Vin = 12V, RL = 2.5
4.75
5.25
V
Vin = 12V, RL = 2.5
0
2
A
Figure C-1. Car Adapter
To PDA
To Vehicle Power Socket
Installing Compact Flash Type Peripherals If you use the CF cover with the open slot, the unit is no longer rated at IP54 standard and is not safe for industrial use where moisture and dust are present. CAUTION Because the handstrap plate will cover the opening, the handstrap cannot be used with the open CF (compact flash card) cover.
To install a Compact Flash (CF) Type II peripheral, follow these steps:
C-2
® Falcon® 4220 Windows CE PDA
Page 81
Using the Docks
Figure C-2. Compact Flash Type II Memory Card
Open Slot CF Card a
CF Card
Sealed Unit (no opening)
b c 1. Remove the handstrap plate or the handle accessory if there is one on the PDA. Refer to "Installing the Handstrap" on page C-5 and the Handle Accessory Installation Instructions included on the product CD for more information. 2. Remove the screws from the CF cover by using a small Phillips head screwdriver. Remove the CF cover plate. 3. Insert a CF card, making sure it is correctly oriented. Do not force it. Refer to Figure C-2C. 4. Replace the CF cover. You will no longer be able to use the handstrap with a CF type peripheral requiring an open cover.
• For most CF cards, use the closed top cover. Using this cover maintains the IP54 Industrial seal rating. Refer to Figure C-2B. • For CF modules with external antennas, etc., use the CF cover with the open slot at the top. Refer to Figure C-2A.
Using the Docks Refer to the Falcon 4220 Quick Reference Guide and the Falcon 4220 Dock Instruction Sheet for more information on the Falcon 4220 Single- and QuadSlot docks.
Product Reference Guide
C-3
Page 82
Accessories & Peripherals
Using the Earphones / Microphone To use the Earphones/Microphone cord, connect it to the port along the top left edge of the PDA. Figure C-3. Earphones/Microphone Device Ear/Microphone Port Icon Microphone Earphones/
The Falcon 4220 supports stereo sound. The earphone/microphone is similar to one you receive with a cellular phone or other portable media device. There will be a Voice Record feature in a future release of this product.
Ethernet Port
CAUTION
When ever you use the Ethernet Adapter, you must wait a minimum of 60 seconds before removing the Falcon from the dock. If you do not, the unit will lock up and you must perform a warm reset. (Refer to the Quick Reference Guide for instructions on warm resetting the Falcon.)
You can also connect the device via the dock to the Host PC via an Ethernet Port. You must install the Ethernet adapter on the dock first. The Ethernet Port is “plug and play” once the Ethernet adapter is installed. Please refer to the instruction sheet that comes with your Ethernet Port for instructions on Installation.
C-4
® Falcon® 4220 Windows CE PDA
Page 83
Installing the Handstrap
Installing the Handstrap To use the PDA for extended periods of time, install the handstrap for increased comfort and usability. To install the handstrap, you must have the standard CF cover installed. Because the handstrap plate will cover the opening, the handstrap cannot be used with the open CF (compact flash card) cover.
Complete the following steps: 1. Turn the PDA face-down on a clean, dry surface. Ensure that power is OFF. 2. Use a small Phillips head screwdriver to remove the two screws securing the CF cover to the PDA. Align the strap plate with the CF cover. (Refer to Figure C-4A.) Figure C-4. Installing the Handstrap
Strap and Strap Plate
CF Cover
A b aB 3. Reinstall the screws to secure the both the CF Cover and the strap plate into place. 4. Pull the plastic tab down as shown in Figure C-4B to insert the strap into the strap recess at the bottom of the unit. The procedure for installing the Strap Plate and the Strap is complete.
Product Reference Guide
C-5
Page 84
Accessories & Peripherals
Installing the Handle Refer to the Instruction Sheet that comes with the handle for complete instructions on installation. Refer to the Product CD for an electronic copy.
Using a High Capacity Battery There is also an optional high capacity battery available. This battery is rated at 2700mAh. This battery upgrade kit comes with a high capacity battery cover as shown below. Figure C-5. Optional High Capacity Battery and Battery Cover
High Capacity Battery Cover
Standard Battery Cover
Latch Standard Battery Pack High Capacity Battery Pack
The High Capacity battery takes about 50% longer to charge in the PDA with the power adapter, in the PDA the dock, in the dock’s spare battery slot, or the battery charger. Please refer to the Quick Reference Guide for a table showing battery charging methods, durations, and LED indicators.
C-6
® Falcon® 4220 Windows CE PDA
Page 85
Holster
Holster There is a heavy duty nylon holster available as an accessory for the both the handled and non-handled versions of the Falcon PDA. It features a belt mount (clip on both sides for left or right mount) and is shown in Figure C-6. Figure C-6. Holster
Product Reference Guide
C-7
Page 86
Accessories & Peripherals
Using the IrDA Port Use the IrDA Port to synchronize data transmission with a desktop computer, portable printer, or another handheld device with an IrDA port. To use the IR port, position the IR port of both devices towards each other. Remove the protective shipping overlay from the IrDA port of both devices (if applicable). Figure C-7. Using the IrDA Port Falcon 4220 IrDA Port Path of the IrDA beam (Not visible) Palm Device IrDA Port
Falcon 4220
Palm Device with IRDA Port IR connections are very sensitive to distance and angle, so it is best to aim and position the IR ports as close as possible to each other. In order to receive or send data, both devices must use the same software from which the data is being beamed.
C-8
® Falcon® 4220 Windows CE PDA