Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 10 of 12

Falcon 4220 Windows CE .NET Ruggedized PDA Product Reference Guide: Preface, pages 87 to 96

Pages 87 to 96 of 116, from Falcon 4220 Windows CE .NET Ruggedized PDA Product Reference Guide

The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC 4220 and Datalogic 4220

Page 87

Using SD Memory Card

Using SD Memory Card Secure Digital memory cards come in various data storage sizes. To use a Secure Digital (SD) type card, complete the following steps: 1. Remove the SD cover located along the left side of the unit by removing the two screws with a Phillips head screw-driver. Figure C-8. Secure Digital Card

SD Cover SD Card 2. Make sure that the SD card is oriented correctly with the small notch on the top left, and insert it into the SD card slot. 3. Replace the SD cover and screws securely. To remove the card, remove the cover and press the exposed edge of the card to release it.

Product Reference Guide

C-9

Page 88

Accessories & Peripherals

Using the USB / Serial Connection Use either a USB or serial connection cable to synchronize your data transmission with a Host PC. Use the appropriate connection for the system you are using. Figure C-9. Serial and USB Data Synchronization Cables Device USB Connection

Device Serial Connection

USB Cable

Host USB Connection

Device USB Connection

Serial Cable

You must install Microsoft ActiveSync v3.7 or higher on the Host PC prior to synchronizing data. For more information on data synchronization using Microsoft ActiveSync, refer to "Connecting PDA to Host PC" on page 4-3 and Microsoft’s website.

C-10

® Falcon® 4220 Windows CE PDA

Page 89

Appendix D Cable & Connector Configurations Introduction The following pages contain pinout information, enabling you to create standard interface cables for use in interconnecting the Falcon to power and/or peripheral devices.

Falcon Termination USB Host Cable Table D-1 lists the Pin number and signal for the Falcon USB Host cable.

Table D-1. USB Cable, Host End Falcon Termination, USB Host Cable

Product Reference Guide

Signal

1

USB_H_5V

2

USB_A_D-

3

USB_A_D+

4

USB-GND

5

USB-GND

Notes

Connected

Pin#

D-1

Page 90

Cable & Connector Configurations

Falcon Termination USB and Serial Cables Table D-2 lists the Pin number and signal for Falcon (client) end of the 22 pin Port, Serial or USB cable.

Table D-2. 22-Pin Port for the USB and Serial Cable,

D-2

Signal

Notes

1

DC_IN

5V Input from Adapter

2

DC_IN

5V Input from Adapter

3

DC_IN

5V Input from Adapter

4

GND

5

DSR

RS232 signal

6

RXD

RS232 signal

7

CTS

RS232 signal

8

GND

9

DCD

RS232 signal

10

RTS

RS232 signal

11

TXD

RS232 signal

12

DTR

RS232 signal

13

USB_H_5

14

F_RING

15

GND

16

USB_B_D- (USB Client)

17

USB_B_D+ (USB Client)

18

GND

19

HOT SYNC

20

USB_C_5V

21

GND

22

V+3.3

RS232 signal

Input, Sync signal for USB client, active high

No Connection

All Pins must be Connected

Pin#

All Pins Must be Connected

Falcon Termination USB & Serial Cable

3.3 Volt power

® Falcon® 4220 Windows CE PDA

Page 91

PC Termination Serial Cable

PC Termination Serial Cable Table D-3 lists the Pin number and signal for PC end of the Serial cable for the

Falcon. Table D-3. Serial Cable, PC End PC Termination (DB9-Female), Serial Cable

Product Reference Guide

Pin#

Signal

1

DTR

2

RXD

3

TXD

4

DCD

5

GND

6

DSR

7

CTS

8

RTS

9

N/A

D-3

Page 92

Cable & Connector Configurations

NOTES

D-4

® Falcon® 4220 Windows CE PDA

Page 93

Appendix E Maintenance, Troubleshooting, and Technical Support Overview This section contains the following topics: •

"Maintaining the PDA" on page E-1.

•

"Troubleshooting" on page E-2.

•

"Technical Support" on page E-5.

Maintaining the PDA With normal use, the PDA, Dock, 4-Slot Dock and 4-slot battery charger require no maintenance. For trouble-free service, observe the following tips when using the Falcon: •

To prolong its life and avoid problems, keep the Falcon and its dock clean. Use a clean, soft cloth dampened with a mild, dilute cleanser.

•

If you need to clean the display, clean it with a lens cloth or other soft cloth dampened with a mild, dilute cleaning solution.

Never use a pen, pencil, or other sharp object on the Falcon’s display/touch screen. Use only the supplied stylus or plastic-tipped pens intended for use with a touchsensitive screen. Do not immerse the PDA, docks, or battery chargers in liquid. Do not use abrasive paper/cloth or abrasive/corrosive cleaners to clean the unit. CAUTION

Use the stylus on the <Reset> button; never use a paper clip Refer to the Quick Reference Guide for information on the cold reset procedure. Using a paper clip or other sharp object can puncture the key, disabling the reset function, rupturing the industrial seal, and voiding your warranty.

Product Reference Guide

E-1

Page 94

Maintenance, Troubleshooting, and Technical Support

Troubleshooting Table E-1. Troubleshooting Problems, Causes, and Solutions Problem The PDA does not turn on.

Possible Cause The battery pack is not charged.

Solution Charge or replace the battery pack in the PDA.

The battery pack not installed Ensure the battery pack is installed properly. properly. System crash. Rechargeable battery pack did not charge.

Characters are not visible on the display.

Perform a cold reset. Refer to the Quick Reference Guide for information on the reset procedure.

Replace the battery pack. If the PDA still does not operate, try a warm reset, then a cold reset; Refer Battery cycle life has expired. to the Quick Reference Guide for information on the reset procedure. The Falcon is not firmly seated in the dock.

Make sure that the Falcon is firmly seated in the dock. If it is not firmly seated, battery charging will NOT be initiated.

The PDA was removed from the dock while battery was charging.

Insert the PDA in dock and begin charging. The initial charge of the battery pack and backup battery takes thirteen (13) hours. Subsequent charging cycles take (4) hours. If both the battery pack and the backup battery are allowed to discharge completely, you must recharge both batteries for thirteen (13) hours.

The PDA is not powered on.

Press the <Power> key.

Turn the backlight off or on using the <Power/BackThe ambient room light is not light> key as a toggle. Refer to the "Power/Backsufficient to see the display. light Key" starting on page 1-8.

During data communicaTerminal removed from dock tion, no data was transmit- or unplugged from host PC ted, or transmitted data was during communications. incomplete.

Replace the terminal in the dock, or replace the serial cable, and retransmit.

Falcon is not firmly seated in the dock.

Make sure that the Falcon is firmly seated in the dock. If it is not firmly seated, communication with the Host PC will NOT be initiated.

Incorrect cable configuration.

See your System Administrator.

Communication software was Perform setup as described in "Transferring Files" incorrectly installed or configon page 4-4. ured.

E-2

® Falcon® 4220 Windows CE PDA

Page 95

Troubleshooting

Problem

Possible Cause

Solution

The PDA has gone into suspend mode and is inactive.

The PDA turns off (suspends) after a period of inactivity. To resume, press the <Power> key. (refer to "Suspend Mode" on page 1-1. You can set duration from one to 30 minutes. Refer to "Power Configuration" on page 3-8 to modify the default settings.

The Quick ScanSet application has not been started.

Go to Start > Programs > Scanner > Quick ScanSet to open the bar code scanning application. Refer to "Quick ScanSet Application" on page 2-5 for more information on using this application.

Protective covering not removed on units equipped with a laser scanner.

Remove the protective covering.

The PDA turns itself off.

The PDA does not accept scanned input.

If the bar code scan fails, adjust the reading angle or distance. Make sure that the scanner beam scans across all bars of the bar code. Refer to FigScanner is not correctly posi- ure 2-8 on page 2-13. Aim the scan beam at the center of the bar code. tioned to read the bar code. • Position the device close to bar code when scanning small bar codes. • Position it at a distance when scanning larger bar codes. Be sure the symbol is not defaced. Unreadable bar code.

Ensure that the unit is programmed to read that symbology.

Distance between exit window Be sure you are within proper scanning range and and bar code is incorrect. scan line is perpendicular and crosses all bars.

Product Reference Guide

The PDA is not programmed to generate a beep.

If you are expecting a beep on a good decode and don’t hear one, check that the application is set to generate a beep on good decode.

Battery is low.

If the scanner stops emitting a scanner beam when you press the trigger, check your battery level. Note: If the scanner is still not reading symbols, contact your PSC reseller.

E-3

Page 96

Maintenance, Troubleshooting, and Technical Support

RF Connectivity Troubleshooting Gather facts: • Falcon type • AP & RF card brand (ensure latest version of firmware installed) • Host type • Software type • Software version (ensure latest version is installed) • Frequency and duration of issue

START

Does the Falcon respond to a PING command from a PC?

YES

Does the Falcon connect to the host ?

YES RF connectivity obtained. See your software manual for further information or contact PSC technical support.

NO

Potential Problems: • Are the correct drivers installed? • Is the RF card securely installed?

NO

Potential Problems: • Ping Falcon from host or use tracert to determine the location of the breakdown in communication. (For more information on the Ping command, go to the command prompt on the PC and type PING. For more information on the TracErt command, go to the command prompt on the PC and type TracErt.)

E-4

YES Does the Falcon display an error during the boot process?

NO

Does the Falcon associate with the AP ?

NO

Potential Problems: • Security Issue – Check SSID, WEP, LEAP settings • Range Issue

YES

YES

Can you ping the Falcon from the AP ?

NO

NO Can you ping the host from a PC on same subnet ?

Potential Problems: • IP Address Issue • PING the AP from the Falcon

Potential Problems: • Host unavailable

YES Potential Problems: • IP address issue (duplicate address on Falcon). Turn off the Falcon and attempt PING again • Run Tracert command to determine location of breakdown of connectivity. (For more information on the TracErt command, go to the command prompt on the PC and type TracErt. For more information on the Ping command, go to the command prompt on the PC and type PING.)

® Falcon® 4220 Windows CE PDA