The text of a manual · part 5 of 12
Falcon 4220 Windows CE .NET Ruggedized PDA Product Reference Guide: Preface, pages 37 to 46
Pages 37 to 46 of 116, from Falcon 4220 Windows CE .NET Ruggedized PDA Product Reference Guide
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC 4220 and Datalogic 4220
Page 37
Input Panel Properties
Input Panel Properties To change the Soft Input Panel settings: 1. Select Start > Settings > Control Panel > Input Panel. 2. Change the desired settings. 3. To change the Soft Keyboard Options, tap the Options button. 4. Change the soft keyboard options as desired, selecting from: • Large or small keys. • Using gestures for space, backspace, shift, and enter. 5. To exit the Soft Keyboard Options, press OK on the control bar, or press the <Enter> key on the keypad. 6. To exit Input Panel settings, press OK from the control bar, or press the <Enter> key on the keypad.
Internet Settings To change the Internet default settings: 1. Select Start > Settings > Control Panel > Internet Settings. 2. On the General tab (refer to Figure 3-1A), type in the URL of the desired start page and the desired search engine. You can also change the Cache Size, clear the Cache, and Clear the History. 3. On the Connection tab (refer to Figure 3-1B) modify the network access settings as desired.
Product Reference Guide
3-5
Page 38
Configuring a PDA
Figure 3-1. Internet Settings
A B C
4. On the Security tab (refer to Figure 3-1C) modify the security settings as desired. You can enable any of the following by tapping the checkbox: • Allow cookies • Allow TLS 2.0 security • Allow SSL 2.0 security • Allow SSL 3.0 security • Warn when switching across secure and insecure areas. 5. To exit Internet Settings, press OK from the control bar, or press the <Enter> key on the keypad.
3-6
® Falcon® 4220 Windows CE PDA
Page 39
Owner
Owner To change the Owner default settings: 1. Select Start > Settings > Control Panel > Owner Properties. The Input Panel opens to facilitate entering data. 2. Enter data using the input panel or the keypad on the PDA. 3. To exit the Owner Properties control panel, press OK from the control bar, or press the <Enter> key on the keypad. For more information on using the Network ID tab, refer to "Setting up the
Network ID" on page 4-6.
Password To change the Password default settings: 1. Select Start > Settings > Control Panel > Password Properties. 2. Enter the desired password twice as indicated in the two fields. 3. Select to enable password protection at power-on and/or enabling password protection for the screen-saver. 4. To exit the Password control panel, press OK from the control bar, or press the <Enter> key on the keypad.
Product Reference Guide
3-7
Page 40
Configuring a PDA
PC Connection The PC Connection control panel determines how ActiveSync works with the PDA. To modify the default settings: 1. Select Start > Settings > Control Panel > PC Connection. 2. Select the first checkbox to enable direct connections to the desktop computer. 3. Tap the Change Connection button to modify the connection method from USB, IrDA, or Serial. 4. To exit the Change Connection dialog, press OK from the control bar, or press the <Enter> key on the keypad. 5. To exit the PC Connection Properties control panel, press OK from the control bar, or press the <Enter> key on the keypad.
Power Configuration To adjust power management settings, select Start > Settings > Control Panel > Power. Use this control panel to check the charge on the battery or to change the Power settings.
Battery Tab The Battery tab provides change level indicators for Main battery, and Backup battery. To exit, press OK from the command bar, or press the <Enter> key on the keypad.
3-8
® Falcon® 4220 Windows CE PDA
Page 41
Regional settings
Schemes Tab The Schemes tab allows you to determine the User Idle, System Idle, and Suspend mode times when using either battery or AC power. The Power Schemes are additive. To exit, press OK from the command bar, or press the <Enter> key on the keypad.
Regional settings To change the Regional Settings defaults: 1. Select Start > Settings > Control Panel > Regional Settings. 2. Select the desired language/location. 3. Review the Appearance Samples in the bottom half of the screen. 4. Select the tab at the top for any settings you wish to change. Options to modify include Number, Currency, Time, and Date. 5. The Input Panel may open to facilitate data input.
The options to modify does not include changing the language. The PDA will only display in English. Options to modify changes only the default appearance for Number, Currency, Time, and Date.
6. To exit Regional Settings, press OK from the control bar, or press the <Enter> key on the keypad. Product Reference Guide
3-9
Page 42
Configuring a PDA
Scanner Settings To change the Scanner Settings and bar code symbologies, complete as follows: 1. Go to Start > Programs > Scanner > Quick ScanSet to open the bar code scanning application. The only indicator that the program is open is the bar code System Tray icon. 2. Select/tap the bar code icon in the System Tray to open the menu shown on the left in Figure 3-2A. • Select Settings to open the Scanner Configure applet. Figure 3-2. Scanner Configuration Settings
B
A Tap the Quick ScanSet Icon to modify the applet settings.
• You can modify the settings either from the menu (Figure 3-2A) or by selecting Setting > Basic tab (Figure 3-2B). Complete as described in Table 3-1. Table 3-1. Scanner Configuration Menu and Basic Tab Section (Menu Item)
Field Name
Basic
Beep
Function/Operation Tap/enable this checkbox to receive beep tone when scanning, or select from the menu.
Trigger Timeout Select a trigger timeout duration (in seconds) from (sec.) this pull-down list.
3-10
® Falcon® 4220 Windows CE PDA
Page 43
Scanner Settings
Section (Menu Item)
Field Name
Keyboard Message (Result Type)
Function/Operation Select from copy & paste or Type writing. Select a method based upon the bar code scanning application you will use.
Termination Code (Terminator)
Select the desired termination code from the pulldown list.
Continuous Scan Enable (Auto Scan)
Tap/enable this checkbox to receive beep tone when scanning, or select from the menu.
Interval
Select a continuous scan duration (in seconds) from this pull-down list.
Prefix
Type the desired label prefix in this text box.
Suffix
Type the desired label suffix in this text box.
Label
3. On the Barcode tab (Figure 3-3A), select the bar code symbologies you plan to scan from the list. Tap to enable/disable the desired symbologies. Figure 3-3. Scanner Configuration Settings
A B C
4. On the Detail tab (Figure 3-3B), select the desired bar code symbology from the pull-down list and complete the fields as described in Table 3-2. Product Reference Guide
3-11
Page 44
Configuring a PDA
Table 3-2. Scanner Configuration Barcode Tab Field Name
Function/Operation
Symbology list
Select the bar code symbology from this pull-down list.
Enable this Code
Tap/enable this checkbox to enable the selected bar code symbology.
Symbology features
Select the desired features you wish to enable for that specific bar code symbology.
Length
Set the minimum and maximum lengths from the pull-down lists. If the numbers are the same, acceptable bar codes will only be that length. Not all symbologies will have this option enabled.
5. On the General tab (Figure 3-3C), select from the options in Figure 3-2 to save or keep your settings. Table 3-3. Scanner Configuration General Tab Button Name
Function/Operation
Try with Current This button is enabled only if you make changes to the current settings. 1. Tap the Try with Current Setting button. Setting 2. Press the <Scan> key. 3. Check the result. 4. If you wish to keep the new current settings, select the Commit Current Setting button. Commit Current After modifying the current settings, if you wish to keep them, select the Setting Commit Current Setting button. Load Factory Default
After modifying the current settings, if you wish to return to the factory defaults, tap the Load Factory Default button.
Revert to last setting
After modifying the current settings, if you wish to return to the previous settings, tap the Revert to Last Setting button.
6. To exit the Scanner Configuration applet, press OK from the control bar, or press the <Enter> key on the keypad.
3-12
® Falcon® 4220 Windows CE PDA
Page 45
Storage Properties
Storage Properties To change the Storage Properties control panel default settings: Insert a compact flash (CF) or secure digital (SD) storage card into the unit (refer to "Installing Compact Flash Type Peripherals" starting on page C-2). 7. Select Start > Settings > Control Panel > Storage Properties. 8. From the Store Info pull-down list, select the desired storage device. 9. You can also format, dismount, and create partitions on storage devices using this control panel. 10. To save and exit the Storage Properties control panel, press OK from the control bar, or press the <Enter> key on the keypad. Dismounting or formatting the DiskOnChip will erase all files and programs stored in Flash Memory. CAUTION
Product Reference Guide
3-13
Page 46
Configuring a PDA
System Properties Refer to the System control panel for information related to the system.
General Tab Select Start > Settings > Control Panel > System Properties > General tab to determine the following information about your PDA: •
Firmware version (in parens).
•
Serial number (S/N).
Memory Allocation Adjust the Memory Allocation with the following steps: 1. Select Start > Settings > Control Panel > System Properties. 2. Select the Memory tab. 3. Move the slider to adjust memory allocation. Default storage memory is normally set to about 8 MB with the remainder assigned to Program memory. 4. Press the OK button, or the <Enter> key on the Falcon.
3-14
® Falcon® 4220 Windows CE PDA