The text of a manual · part 4 of 12
Falcon 4220 Windows CE .NET Ruggedized PDA Product Reference Guide: Preface, pages 27 to 36
Pages 27 to 36 of 116, from Falcon 4220 Windows CE .NET Ruggedized PDA Product Reference Guide
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC 4220 and Datalogic 4220
Page 27
Firmware Update Utility
Figure 2-6. Installing Dialog
10. Press Finish to exit the installation. Figure 2-7. Installing Dialog
11. Congratulations! You have successfully installed FUU on the host PC.
Product Reference Guide
2-13
Page 28
Software Applications
Updating Falcon Firmware After copying the firmware image to the host PC and extracting the FUU utility, you can upgrade the firmware on your PDA. The following steps require that you have already established an ActiveSync connection between the host computer and the PDA. To establish an ActiveSync connection with the Falcon, refer to "Installing & Setting Up Microsoft® ActiveSync" on page 4-1.
1. Go to Start > Programs > Firmware Update Utility > FUU. 2. Double-click on the FUU.exe file. 3. Verify that ActiveSync is selected from the Communicate Using pull-down list. 4. Click the File Select (Browse...) button and navigate to the file location. 5. Select the current *.bin file and press the Open button. Figure 2-8. Select the.bin file
6. Verify that the PDA is turned on. Insert the Falcon into a powered dock connected to the host computer. 7. Press the Query button on the FUU utility on the host PC.
2-14
® Falcon® 4220 Windows CE PDA
Page 29
Firmware Update Utility
Figure 2-9. Query Terminal
8. Press the Update button on the FUU utility on the host PC. Figure 2-10. Falcon Firmware Update Utility
9. The FUU will compare the selected firmware image with the firmware already loaded on the PDA. If the images are different, the FUU will proceed to update the firmware image on your terminal. Please be patient during this procedure. The firmware image of the PDA can take several minutes to download.
Product Reference Guide
2-15
Page 30
Software Applications
10. After the firmware of your PDA has been updated, you must perform a warm reset on the Falcon (refer to the Quick Reference Guide for instructions on the reset method for your Falcon model.)
Restoring Falcon Firmware If the firmware image on the Falcon 4220 becomes corrupted, the terminal will continue to display the PSC Falcon logo with an error message at the bottom of the screen. This can happen if the firmware update is aborted, as can happen during a power loss. To reinstall the firmware, complete the following steps: 1. Obtain a 64MB compact flash card and format it for FAT-16 format using the Windows format routine on a PC. 2. Download the current nkupd.bin file from the PSC web site 3. Copy nkupd.bin to the compact flash card. 4. Insert the card into the Falcon 4220. 5. Cold reset the device. (Refer to the Quick Reference Guide for information on the cold reset procedure.) 6. Immediately after starting the cold reset, press and hold the down arrow. 7. Once the PDA displays a message at the bottom of the logo screen saying it is checking media, release the down arrow. 8. The unit will locate the firmware on the compact flash card and restore the image. 9. Once the restoration is complete, perform another cold reset on the device to load the new firmware.
AutoCAB The AutoCAB program allows the PDA to automatically reinstall selected applications when the terminal is cold reset. When the Falcon is reset, the AutoCAB program runs automatically and determines if it is a warm or cold reset. If it is a warm reset, the program just exits.
2-16
® Falcon® 4220 Windows CE PDA
Page 31
AutoCAB
If the terminal has been cold reset, the AutoCAB checks to see if there is a DiskOnChip\CAB directory on the terminal. If not, the program just exits. If the CAB directory is found, the program will step through the files in the directory, calling the Windows CAB file installer for each of the files. Once all of the CAB files have been installed, the program will exit. As an example, assume you received an application program as a cab file named INVENTORY.CAB. If the cab file were to be copied to the Falcon and then double clicked, it will be installed and the cab file would be deleted. If the terminal were to be cold reset, the application would be lost, requiring the cab file to be downloaded and installed again. By copying the cab file to the DiskOnChip\CAB directory and allowing AutoCAB to run, the application is installed but the cab file is not removed. So if the terminal is cold reset, the current installation will be removed, but AutoCAB will automatically reinstall it.
Product Reference Guide
2-17
Page 32
Software Applications
AutoCE The AutoCE program allows the user to create a list of applications to run when the PDA is reset. Each application may be designated to run only on a cold reset, or on both warm and cold reset. The applications run sequentially, allowing interdependencies to be handled. To create the application list, use a text editor to build a file named autoexec.ini. This file should contain the fully qualified names of each application to run. Once the file is created, it should be copied into the DiskOnChip directory. Any line that begins with a space or a # will be treated as a comment and ignored by AutoCE. To designate an application to run only at cold boot, begin the line with an exclamation mark. Please note that any application arguments containing spaces such as directory names must be bracketed by quotation marks. The following sample autoexec.ini file shows the use of quotes around arguments, as well as an example of how to copy files. cmd /C echo “Hello World” > “DiskOnChip\hello.txt” cmd /C copy “DiskOnChip\hello.txt” “def.txt” !cmd /C copy “DiskOnChip\hello.txt” “DiskOnChip\def.txt” The first line will generate a file in the DiskOnChip directory named hello.txt whenever the terminal is reset. The second line will copy this file to the root directory as def.txt. The third line will only run when the terminal is cold reset, and will copy the hello.txt file to def.txt in the DiskOnChip. The following sample file demonstrates the use of an application in the DiskOnChip. #\DiskOnChip\echobox test comment \DiskOnChip\echobox AutoCE Test 1 !\DiskOnChip\echobox AutoCE Test 3 \DiskOnChip\echobox AutoCE Test 2 The first line begins with a # and is treated as a comment. The second line will run the echobox command (sample application program) with 3 arguments whenever the terminal is reset. The third line will run echobox but only when the terminal is cold reset. The fourth line will again run the echobox command whenever the terminal is reset.
2-18
® Falcon® 4220 Windows CE PDA
Page 33
Chapter 3 Configuring a PDA Customizing the Settings To change the settings on your new PDA, select Start > Settings > Control Panel to view the Control Panels and settings you can modify. This chapter contains the following topics: •
"Aligning the Touchscreen Display" on page 3-2
•
"Date and Time" on page 3-3.
•
"Display Configuration" on p. 3-4.
•
"Input Panel Properties" on p. 3-5.
•
"Internet Settings" on page 3-5.
•
"Owner" starting on page 3-7.
•
"Password" starting on page 3-7.
•
"PC Connection" on page 3-8.
•
"Power Configuration" on page 3-8.
•
"Regional settings" on page 3-9.
•
"Scanner Settings" on page 3-10.
•
"Storage Properties" on page 3-13.
•
"System Properties" on page 3-14.
•
"Volume and Sounds" on page 3-16.
•
"Falcon Management Utility" on page 3-17.
Control Panels
Other than the Quick ScanSet applet and FMU (Falcon Management Utility), the list of settings are standard Windows CE .NET settings. For more information on the Windows CE .NET operating system, please refer to Microsoft’s website at http://www.microsoft.com/windows/embedded/ce.net/.
Product Reference Guide
3-1
Page 34
Configuring a PDA
Aligning the Touchscreen Display You might need to align the touch screen (i.e. when you notice that when you attempt to select one item with the stylus, another item is erroneously selected). 1. To align the touch screen, press <FN2>+ <Enter> to open the align Screen dialog as shown to the right 2. Carefully press and briefly hold stylus on the center of the target as the target moves around the screen.
For more information about using the stylus with the touch-sensitive display, refer to the following: • "Using the Stylus" on page 2-2. • "Soft Keypad/Input Panel" on page 2-9.
3-2
® Falcon® 4220 Windows CE PDA
Page 35
Date and Time
Date and Time In the Date/Time options, you can change the year, month, date, time, time zone, or select automatic adjust for Daylight Savings Time. To set or change the date and time: 1. Select Start > Settings > Control Panel > Date/Time. 2. Select the month to open a pulldown list of months or press the arrow buttons on either side of the month to increase or decrease the month. 3. To change the year, select the year to open a numeric dial. Select the up arrow to increase the value; select the down arrow to decrease the value. Or you can type a new year value in the field. 4. To change the time, select the hour, minute, seconds, or AM/ PM and select the up arrow to increase the value; select/tap the down arrow to decrease the value. You can also type a new time value in the field. 5. Select your correct time zone from the pull-down list. 6. To automatically adjust the clock for Daylight Savings Time, enable the checkbox at the bottom of the screen. 7. Select Apply to make save your changes [and make additional modifications] or select OK to exit the Date/Time settings.
Product Reference Guide
3-3
Page 36
Configuring a PDA
Display Configuration To modify the display and/or backlight of the PDA refer to the following:
Background To change the Background image: 1. The current file is located in the Windows directory with the PSC logo file named PSC.bmp. 2. Place a new image in the Windows directory. This file must be exactly 240 by 320 pixels. 3. Select Start > Settings > Control Panel > Display. 4. Select the new file name by using the Browse button. 5. To exit the Background settings, press OK from the control bar, or press the <Enter> key on the keypad.
Backlight To change the Backlight default settings: 1. Select Start > Settings > Control Panel > Display > Backlight tab. 2. Select the Backlight tab. 3. Modify the backlight pull-down list settings to suit your requirements. 4. Tap/enable the User Dim Backlight checkbox to allow the user to adjust the backlight by using the <FN2> key with navigation key to increase or decrease the backlight. 5. To exit the Backlight settings, press OK from the control bar, or press the <Enter> key on the keypad.
3-4