Page 31

LazerData® 12000 Scanner

Installation Manual

12000 Scanner

USER INTERFACE

2

TX232

3

RX232

4

RTS232

5

CTS232

7

SGND

RXD TXD DCD DTR SGND

RTS/CTS HARDWARE HANDSHAKING ENABLED

Figure 2.15 - RS232 main interface connections

Figure 2.16 - RS232 control signals

The RTS232 and CTS232 signals control data transmission and synchronize the connected devices. If the RTS/CTS handshaking protocol is enabled, the LazerData 12000 Scanner activates the RTS232 output to indicate a message is to be transmitted. The receiving unit activates the CTS232 input to enable the transmission.

2.14 - Installation

Page 32

LazerData® 12000 Scanner

Installation Manual

RS485-nonpolled interface The RS485-nonpolled interface is a Full Duplex interface. The nonpolled configuration is used for point-to-point connections (over longer distances than those acceptable for RS232 communications) or in electrically noisy environments. The following 25-pin connector pins are used for RS485-nonpolled communications: Pin

Name

Function

2 4 3 5 7

TX485+ TX485RX485+ RX485SGND

RS485 output (+) RS485 output (-) RS485 input (+) RS485 input (-) Signal Ground

12000 Scanner

USER INTERFACE

2

TX485+

4

TX485-

3

RX485+

5

RX485-

7

SGND

RX485

TX485

SGND

Figure 2.17 - RS485-nonpolled connections

To select this interface type, follow the instructions in sections 2.3 and 2.4.

Installation - 2.15

Page 33

LazerData® 12000 Scanner

Installation Manual

RS485-polled interface The RS485-polled interface is a Half Duplex (3 wires + shield) interface. The polled configuration can be used for multidrop connections with a PSC Automation multiplexer or also for a master-slave layout (see section 2.9.1). The following pins of the 25-pin connector are used for RS485-polled communications: Pin Name Function 2 4 7

TX485+ TX485SGND

RS485 input/output (+) RS485 input/output (-) Signal Ground

MULTIPLEXER

12000 Scanner 2

TX485+

4

TX485-

7

SGND

+ RTX485 - RTX485 RS485REF

Figure 2.18 - RS485-polled connections

To select this interface type, follow the instructions in sections 2.3 and 2.4. For this interface type, the multidrop address must also be set on the DIP switch as shown in Fig. 2.19 below. Record this information for further setup of the multidrop line.

SW1 SW1

SW2

SW4

SW3

Figure 2.19 - DIP switch for multidrop address selection

2.16 - Installation

Page 34

LazerData® 12000 Scanner

Installation Manual

The following table shows the address settings where: Position

Address

1

2

3

4

5

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0

1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0

1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0

1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

1 = ON

Position

Address

1

2

3

4

5

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0

1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0

1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0

1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

0 = OFF

Installation - 2.17

Page 35

LazerData® 12000 Scanner

Installation Manual

Figure 2.20 below shows a multidrop configuration with LazerData 12000 Scanners connected to a Multiplexer.

max. 2 m.

120 Ohm

6.6 ft.

1

12000 Scanner #x (up to 31) 12000 Scanner

1

CHASSIS

1

#1

2 4 7 2 4 7 2

12000 Scanner

4

#0

7 max. 1200 m. 1,312 yds.

TX485+ TX485SGND three wires + shield +RTX485

MULTIPLEXER

-RTX485 RS485REF SHIELD

120 Ohm

Figure 2.20 - LazerData 12000 Scanner multidrop connection to a multiplexer

2.18 - Installation

Page 36

LazerData® 12000 Scanner

Installation Manual

20-mA current loop interface The LazerData 12000 Scanner only supports passive type, current loop connections. The following pins of the 25-pin connector are used: Pin

Name

Function

5 3 4 2

CLINCLIN+ CLOUTCLOUT+

Current Loop Input (-) Current Loop Input (+) Current Loop Output (-) Current Loop Output (+)

12000 Scanner

USER INTERFACE 5

C.L. IN-

3

C.L. IN+

4

C.L. OUT-

2

C.L. OUT+

I = 20 mA

I = 20 mA

MAX. 300 METERS

Figure 2.21 – 20-mA C.L. connections

To select this interface type, follow the instructions in sections 2.3 and 2.4.

Installation - 2.19

Page 37

LazerData® 12000 Scanner

Installation Manual

2.7.3 Auxiliary RS232 interface The auxiliary serial interface is used exclusively for RS232 point-to-point connections. The parameters relative to the auxiliary interface (baud rate, data bits, etc.) as well as particular operating modes, such as local echo, can be defined using the LDHOST utility program or Host Mode programming. For more details refer to section 2.9 and to the section "Auxiliary Interface Menu" in the LDHOST Help Online. The following pins of the 25-pin connector are used to connect the RS232 auxiliary interface: Pin Name Function 20 RXAUX Auxiliary input 21 TXAUX Auxiliary output 23 CTSAUX Auxiliary handshake 24 RTSAUX Auxiliary handshake 7 SGND Signal Ground 12000 Scanner

USER INTERFACE

20 RXAUX TXD 21 TXAUX RXD 23 CTSAUX 24 RTSAUX 7

SGND

DTR DCD SGND

RTS/CTS HARDWARE HANDSHAKING ENABLED

Figure 2.22 - RS232 auxiliary interface connections

The RTSAUX and CTSAUX signals control data transmission and synchronize the connected devices. If the RTS/CTS handshaking protocol is enabled, the LazerData 12000 Scanner activates the RTSAUX output to indicate a message is to be transmitted. The receiving unit activates the CTSAUX input to enable the transmission.

2.20 - Installation

Page 38

LazerData® 12000 Scanner

Installation Manual

2.7.4 Inputs The inputs available on the LazerData 12000 Scanner are the pins relative to the code presence sensor, as indicated below: Pin 18 19

Name PS+ PS-

Function Presence sensor (input+) Presence sensor (input-)

The inputs indicated are always used to connect the code presence sensor which tells the scanner to scan for a code. The yellow LED (Figure A, 5 ) is on during the active phase of the PS signal, indicating that decoding can take place. This input is optocoupled and can be driven by both an NPN- or PNP-type command. The connections are indicated in the following diagrams: Vext 30 Vdc max.

12000 Scanner

PRESENCE SENSOR

+ 5V 18

PS+

19

V

PSSignal

Figure 2.23 - Input NPN command using external power

12000 Scanner

PRESENCE SENSOR 9

VS

18

PS+

19

PS-

25

GND

V

+ 5V

Signal Ground

Figure 2.24 - Input NPN command using LazerData 12000 power

Installation - 2.21

Page 39

LazerData® 12000 Scanner

Installation Manual

Vext 30 Vdc max.

12000 Scanner

PRESENCE SENSOR V

+ 5V 18

PS+

19

PS-

Signal

Ground

Figure 2.25 - Input PNP command using external power

12000 Scanner

PRESENCE SENSOR 9

VS

18

PS+

19

PS-

25

GND

+ 5V

V Signal

Figure 2.26 - Input PNP command using LazerData 12000 power

The electrical features are given below: Maximum voltage Maximum current

30 VDC 25 mA

An anti-disturbance filter is implemented on the presence sensor input with a nominal delay of about 5 milliseconds.

2.22 - Installation

Page 40

LazerData® 12000 Scanner

Installation Manual

2.7.5 Outputs In addition to the pins relative to the communication interfaces as described in previous sections, the following pins are present on the scanner’s 25-pin connector: Pin 8 22 11 12 14 15

Name NO READ+ NO READRIGHT+ RIGHTWRONG+ WRONG-

Function No read output (+) No read output (-) Right read output (+) Right read output (-) Wrong read output (+) Wrong read output (-)

The NO READ output activates when the code signaled by the presence sensor is not decoded. USER INTERFACE

12000 Scanner

Vext 40 Vdc max

8

NO READ+

22 NO READ-

Figure 2.27 - NO READ output connection

The RIGHT output activates when the code is decoded correctly. 12000 Scanner

USER INTERFACE Vext 40 Vdc max

11

RIGHT+

12

RIGHT-

Figure 2.28 - RIGHT code output connection

Installation - 2.23