Page 31
LazerData® 12000 Scanner
Installation Manual
12000 Scanner
USER INTERFACE
2
TX232
3
RX232
4
RTS232
5
CTS232
7
SGND
RXD TXD DCD DTR SGND
RTS/CTS HARDWARE HANDSHAKING ENABLED
Figure 2.15 - RS232 main interface connections
Figure 2.16 - RS232 control signals
The RTS232 and CTS232 signals control data transmission and synchronize the connected devices. If the RTS/CTS handshaking protocol is enabled, the LazerData 12000 Scanner activates the RTS232 output to indicate a message is to be transmitted. The receiving unit activates the CTS232 input to enable the transmission.
2.14 - Installation
Page 32
LazerData® 12000 Scanner
Installation Manual
RS485-nonpolled interface The RS485-nonpolled interface is a Full Duplex interface. The nonpolled configuration is used for point-to-point connections (over longer distances than those acceptable for RS232 communications) or in electrically noisy environments. The following 25-pin connector pins are used for RS485-nonpolled communications: Pin
Name
Function
2 4 3 5 7
TX485+ TX485RX485+ RX485SGND
RS485 output (+) RS485 output (-) RS485 input (+) RS485 input (-) Signal Ground
12000 Scanner
USER INTERFACE
2
TX485+
4
TX485-
3
RX485+
5
RX485-
7
SGND
RX485
TX485
SGND
Figure 2.17 - RS485-nonpolled connections
To select this interface type, follow the instructions in sections 2.3 and 2.4.
Installation - 2.15
Page 33
LazerData® 12000 Scanner
Installation Manual
RS485-polled interface The RS485-polled interface is a Half Duplex (3 wires + shield) interface. The polled configuration can be used for multidrop connections with a PSC Automation multiplexer or also for a master-slave layout (see section 2.9.1). The following pins of the 25-pin connector are used for RS485-polled communications: Pin Name Function 2 4 7
TX485+ TX485SGND
RS485 input/output (+) RS485 input/output (-) Signal Ground
MULTIPLEXER
12000 Scanner 2
TX485+
4
TX485-
7
SGND
+ RTX485 - RTX485 RS485REF
Figure 2.18 - RS485-polled connections
To select this interface type, follow the instructions in sections 2.3 and 2.4. For this interface type, the multidrop address must also be set on the DIP switch as shown in Fig. 2.19 below. Record this information for further setup of the multidrop line.
SW1 SW1
SW2
SW4
SW3
Figure 2.19 - DIP switch for multidrop address selection
2.16 - Installation
Page 34
LazerData® 12000 Scanner
Installation Manual
The following table shows the address settings where: Position
Address
1
2
3
4
5
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0
1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
1 = ON
Position
Address
1
2
3
4
5
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0
1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0 = OFF
Installation - 2.17
Page 35
LazerData® 12000 Scanner
Installation Manual
Figure 2.20 below shows a multidrop configuration with LazerData 12000 Scanners connected to a Multiplexer.
max. 2 m.
120 Ohm
6.6 ft.
1
12000 Scanner #x (up to 31) 12000 Scanner
1
CHASSIS
1
#1
2 4 7 2 4 7 2
12000 Scanner
4
#0
7 max. 1200 m. 1,312 yds.
TX485+ TX485SGND three wires + shield +RTX485
MULTIPLEXER
-RTX485 RS485REF SHIELD
120 Ohm
Figure 2.20 - LazerData 12000 Scanner multidrop connection to a multiplexer
2.18 - Installation
Page 36
LazerData® 12000 Scanner
Installation Manual
20-mA current loop interface The LazerData 12000 Scanner only supports passive type, current loop connections. The following pins of the 25-pin connector are used: Pin
Name
Function
5 3 4 2
CLINCLIN+ CLOUTCLOUT+
Current Loop Input (-) Current Loop Input (+) Current Loop Output (-) Current Loop Output (+)
12000 Scanner
USER INTERFACE 5
C.L. IN-
3
C.L. IN+
4
C.L. OUT-
2
C.L. OUT+
I = 20 mA
I = 20 mA
MAX. 300 METERS
Figure 2.21 – 20-mA C.L. connections
To select this interface type, follow the instructions in sections 2.3 and 2.4.
Installation - 2.19
Page 37
LazerData® 12000 Scanner
Installation Manual
2.7.3 Auxiliary RS232 interface The auxiliary serial interface is used exclusively for RS232 point-to-point connections. The parameters relative to the auxiliary interface (baud rate, data bits, etc.) as well as particular operating modes, such as local echo, can be defined using the LDHOST utility program or Host Mode programming. For more details refer to section 2.9 and to the section "Auxiliary Interface Menu" in the LDHOST Help Online. The following pins of the 25-pin connector are used to connect the RS232 auxiliary interface: Pin Name Function 20 RXAUX Auxiliary input 21 TXAUX Auxiliary output 23 CTSAUX Auxiliary handshake 24 RTSAUX Auxiliary handshake 7 SGND Signal Ground 12000 Scanner
USER INTERFACE
20 RXAUX TXD 21 TXAUX RXD 23 CTSAUX 24 RTSAUX 7
SGND
DTR DCD SGND
RTS/CTS HARDWARE HANDSHAKING ENABLED
Figure 2.22 - RS232 auxiliary interface connections
The RTSAUX and CTSAUX signals control data transmission and synchronize the connected devices. If the RTS/CTS handshaking protocol is enabled, the LazerData 12000 Scanner activates the RTSAUX output to indicate a message is to be transmitted. The receiving unit activates the CTSAUX input to enable the transmission.
2.20 - Installation
Page 38
LazerData® 12000 Scanner
Installation Manual
2.7.4 Inputs The inputs available on the LazerData 12000 Scanner are the pins relative to the code presence sensor, as indicated below: Pin 18 19
Name PS+ PS-
Function Presence sensor (input+) Presence sensor (input-)
The inputs indicated are always used to connect the code presence sensor which tells the scanner to scan for a code. The yellow LED (Figure A, 5 ) is on during the active phase of the PS signal, indicating that decoding can take place. This input is optocoupled and can be driven by both an NPN- or PNP-type command. The connections are indicated in the following diagrams: Vext 30 Vdc max.
12000 Scanner
PRESENCE SENSOR
+ 5V 18
PS+
19
V
PSSignal
Figure 2.23 - Input NPN command using external power
12000 Scanner
PRESENCE SENSOR 9
VS
18
PS+
19
PS-
25
GND
V
+ 5V
Signal Ground
Figure 2.24 - Input NPN command using LazerData 12000 power
Installation - 2.21
Page 39
LazerData® 12000 Scanner
Installation Manual
Vext 30 Vdc max.
12000 Scanner
PRESENCE SENSOR V
+ 5V 18
PS+
19
PS-
Signal
Ground
Figure 2.25 - Input PNP command using external power
12000 Scanner
PRESENCE SENSOR 9
VS
18
PS+
19
PS-
25
GND
+ 5V
V Signal
Figure 2.26 - Input PNP command using LazerData 12000 power
The electrical features are given below: Maximum voltage Maximum current
30 VDC 25 mA
An anti-disturbance filter is implemented on the presence sensor input with a nominal delay of about 5 milliseconds.
2.22 - Installation
Page 40
LazerData® 12000 Scanner
Installation Manual
2.7.5 Outputs In addition to the pins relative to the communication interfaces as described in previous sections, the following pins are present on the scanner’s 25-pin connector: Pin 8 22 11 12 14 15
Name NO READ+ NO READRIGHT+ RIGHTWRONG+ WRONG-
Function No read output (+) No read output (-) Right read output (+) Right read output (-) Wrong read output (+) Wrong read output (-)
The NO READ output activates when the code signaled by the presence sensor is not decoded. USER INTERFACE
12000 Scanner
Vext 40 Vdc max
8
NO READ+
22 NO READ-
Figure 2.27 - NO READ output connection
The RIGHT output activates when the code is decoded correctly. 12000 Scanner
USER INTERFACE Vext 40 Vdc max
11
RIGHT+
12
RIGHT-
Figure 2.28 - RIGHT code output connection
Installation - 2.23