Page 21
LazerData® 12000 Scanner
2.4
Installation Manual
MAIN INTERFACE SELECTION
One of the following interface types can be selected to connect the main interface of the LazerData 12000 Scanner to the host computer. EIA RS232
20 mA CURRENT LOOP
EIA RS485-POLLED
EIA RS485-NONPOLLED
To select the interface type, position the jumper block as indicated in the diagram below:
SW1 SW3
SW2
SW4
SW3
SW3
SW4
RS232
SW3
RS485-POLLED
SW2
SW2
SW4
SW2
SW4
SW3
SW2
SW4
Figure 2.3 - Interface type selection
The RS232 interface type is factory set.
2.4 - Installation
20 mA C.L.
RS485-NONPOLLED
Page 22
LazerData® 12000 Scanner
Installation Manual
2.5
PHYSICAL INSTALLATION
The LazerData 12000 Scanner can be installed to operate in different positions. The four screw holes (M4 x 5) on the body of the reader are for physical attachment (Figure A, 2 ). Use the following diagram – that gives the overall dimensions – for scanner installation. Note that the dimensions are given in millimeters and inches. Refer to section 2.8 for correct positioning.
Mounting Bracket mm in
Figure 2.4 - Overall dimensions
Installation - 2.5
Page 23
LazerData® 12000 Scanner
2.6
Installation Manual
JUNCTION BOX (JBOX) INSTALLATION
The JBOX provides a passive connection between your scanner and outside system communication cables in a fast and practical way. It is an alternative to the 25-pin connector models. Figure 2.5 shows the basic layout of LazerData 12000 Scanner using the JBOX. Scanner cable
Junction Box
12000 Scanner
System cables
Figure 2.5 - Scanner using JBOX
For JBOX connections, the scanner has a cable that terminates in a 24-pin connector that plugs into the junction box. The system cables pass through six external compression connectors on the JBOX and the individual cable wires connect to internal spring-clamp terminal blocks that provide access to all scanner signals.
2.6.1 Mounting the JBOX The diagram below shows the JBOX dimensions and mounting hole locations.
Compression connectors PG7 N°6
Figure 2.6 - JBOX dimensions
2.6 - Installation mm in
Page 24
LazerData® 12000 Scanner
Installation Manual
The JBOX is designed to be mounted to a panel (or wall) of metal, plastic or other appropriate material using the mounting screws provided in the package. To mount the JBOX – 1) Open the JBOX by unscrewing the four cover screws. If necessary, you can use the JBOX itself as a template through which you can mark the locations for the mounting screws. Once you mark the mounting screw locations, set the JBOX aside and drill two small pilot holes in the panel or wall. 2) Align the JBOX on the panel pilot holes, insert the two self-threading screws with their washers through the JBOX, and screw them into the panel until tight (see Figure 2.7) and the JBOX is securely fastened.
Figure 2.7 - Mounting JBOX
Installation - 2.7
Page 25
LazerData® 12000 Scanner
Installation Manual
2.6.2 Wiring the JBOX To electrically wire the JBOX– 1) Open the junction box by unscrewing the four cover screws. 2) Pass all system cables through the compression connectors in the JBOX housing. 3) Connect the power and input/output signals: • Prepare the individual wires of the system cables by stripping the insulation back approximately 11 mm (0.43 inch). • Using a screwdriver or other tool, push down on the orange lever directly above the clamp (see Figure 2.8). • Insert the wire into the clamp and release the lever. The wire will now be held in the spring clamp.
Figure 2.8 - System cable connections to the junction box
The wiring used can be solid or stranded but must meet the following specifications. Positions 1-4:
24 - 16 AWG
0.2 - 1.5 mm²
Positions 5-39:
26 - 20 AWG
0.14 - 0.5 mm²
The JBOX pinouts are indicated in the following table.
2.8 - Installation
Page 26
LazerData® 12000 Scanner
Installation Manual
JBOX pinout for LazerData 12000 Scanner Pin
Name
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 *24 *25 *26 27 28 29 30 31 32 33 34 35 36 37 38 39
VS SGND VS SGND CHASSIS VS VS PS+ PSSGND SGND VS VS n.c. n.c. SGND SGND NOREAD+ NOREADRIGHT+ RIGHTWRONG+ WRONGTX232/TX485+/CLOUT + RTS232/TX485-/CLOUTSGND n.c. SGND TX232/TX485+/CLOUT+ RTS232/TX485-/CLOUTSGND RX232/RX485+/CLIN+ CTS232/RX485-/CLINSGND TXAUX RTSAUX SGND RXAUX CTSAUX
*
18
J1
39
1
5
17
Figure 2.9 - JBOX connector and pinout
To facilitate an NEC Class 2 Power Unit connection, use the correct female plug adapter. Junction Box NEC Class 2 Power supply
Female Plug System cables Figure 2.10 - NEC Class 2 Power unit connections
The signals on pins 24, 25, and 26 are repeated on pins 29, 30, and 31 to facilitate network connections (that is, multiplexer connections using the RS485-polled Interface). In this way the network bus can enter and exit the junction box from different spring clamps but be physically connected together.
Installation - 2.9
Page 27
LazerData® 12000 Scanner
Installation Manual
4) After wiring the JBOX and while the scanner is unplugged from the power supply (see Figure 2.11) – • place the scanner cable so that the rubber seal fits into the cutout in the housing of the junction box, and • plug the 24-pin connector into connector J1 on the PCB inside the JBOX.
Rubber seal
J1
Scanner cable
Figure 2.11 - Scanner cable connections to the JBOX
5) Close the JBOX using the four cover screws ensuring the rubber seal is fitted correctly between the parts of the housing. You have now installed the JBOX and completed the electrical connections for your scanning system. Should it become necessary to disconnect the scanner from the JBOX, simply reverse the procedure in step 4.
2.10 - Installation
Page 28
LazerData® 12000 Scanner
Installation Manual
2.7
ELECTRICAL CONNECTIONS FOR 25-PIN MODELS
The 25-pin connector scanner models (see section 1.3) are equipped with a cable terminated by a 25-pin D-sub connector for connection to the power supply and input/output signals. The functions of the connector pins are given in the following table.
Figure 2.12 - 25-pin D-sub connector
25-pin D-sub connector pinout Pin 13 25 1 9 18 19 8 22 11 12 14 15 2* 3* 4* 5* 7 20 21 23 24 6, 10, 16, 17 *
Name
Function
VS SGND CHASSIS VS PS+ PSNO READ + NO READ RIGHT + RIGHT WRONG + WRONG TX232/TX485+/CLOUT+ RX232/RX485+/CLIN+ RTS232/TX485-/CLOUTCTS232/RX485-/CLINSGND RXAUX TXAUX CTSAUX RTSAUX NC
Power supply input voltage (+) Power supply input voltage (-) Chassis Ground Presence sensor supply voltage (+) Presence sensor (+) Presence sensor (-) No read output (+) No read output (-) Right read output (+) Right read output (-) Wrong read output (+) Wrong read output (-) * Main interface signals (see section 2.7.2) Signal Ground Auxiliary input Auxiliary output Auxiliary handshake Auxiliary handshake No Connect
Pins 2, 3, 4, and 5 of the 25-pin connector have different meanings depending on which interface type is selected. To select the interface type, follow the instructions in sections 2.3 and 2.4.
Installation - 2.11
Page 29
LazerData® 12000 Scanner
Installation Manual
2.7.1 Power supply Power can be supplied to the scanner through the pins provided on the 25-pin connector used for communication with the host (Figure 2.13), USER INTERFACE
12000 Scanner 13 VS
V+ (10 - 30 Vdc) 25 GND
SGND CHASSIS
1
Earth Ground
CHASSIS
Figure 2.13 - Power supply connections or through the jack connector on the side of the 25-pin connector for connections to a UL Listed Direct Plug-in Power Unit (Figure 2.14). If the jack input is used to supply power to the LazerData 12000 Scanner, pin 13 is automatically disconnected; the supply voltage for the presence sensor remains on pin 9. The plug connector is not supplied with the LazerData 12000 Scanner.
GND Jack
Plug
V+ (10 - 30 Vdc)
Figure 2.14 - Power supplied using the jack connector
The power must be in the 10- to 30-VDC range only. There is a current peak of about 1A at 10 V caused by the motor starting during power up. It is recommended to connect pin 1 (CHASSIS) to a common earth ground.
2.12 - Installation
Page 30
LazerData® 12000 Scanner
Installation Manual
2.7.2 Main serial interface The signals, relative to the following serial interface types, are available on the input/output connector – EIA RS232 EIA RS485-NONPOLLED EIA RS485-POLLED (for connection with PSC Automation multiplexer) 20-mA PASSIVE CURRENT LOOP The LazerData 12000 Scanner automatically recognizes the type of interface selected at each scanner power up. If the recognized interface type is not compatible with the current communication handshaking, then the system defaults to the XON/XOFF protocol. The parameters of the interface selected (baud rate, data bits, etc.) can be configured using the LDHOST utility program or Host Mode programming. For more details refer to the section "Main Interface Menu" in the LDHOST Help Online. Details regarding the connections and use of the main interface selection are given in the next sections.
RS232 interface The serial interface is used in this case for point-to-point connections. It handles communication with the host computer and allows both transmission of code data and the configuration of the scanner. This is the default interface. The following pins of the 25-pin connector are used for RS232 interface connection: Pin 2 3 4 5 7
Name TX232 RX232 RTS232 CTS232 SGND
Function Transmitted Data Received Data Request To Send Clear To Send Signal Ground
Installation - 2.13