For the PSC 12000 and Datalogic 12000

Page 11

x

Page 12

Installation Manual

1

GENERAL FEATURES

1.1

INTRODUCTION

LazerData® 12000 Scanner

The LazerData 12000 Scanner is a bar code reader complete with decoder. It is available in 16 standard models that were designed to satisfy the most demanding requirements of high performance scanning.

Standard Application Program A Standard Application Program is factory-loaded onto the LazerData 12000 Scanner. This program controls bar code reading, serial port interfacing, data formatting, and many other operating and control parameters. The scanner is completely user-configurable from a host computer using the LDHOST interface utility program provided on diskette with the scanner or using the Host Mode programming procedure – by ESC sequences via the serial interface. There are four different programmable operating modes to suit various bar code reading system requirements. One is the test mode that is used to verify the reading features and exact positioning of the scanner without the need for external tools.

C Programmability The LazerData 12000 Scanner belongs to the generation of PSC Automation scanners that operate under the 'C' programming environment, a recognized industry standard. If your requirements are not met by the Standard Application Program, then Custom Application Programs can be developed by your local PSC Automation, Inc. distributor.

General Features - 1.1

Page 13

LazerData® 12000 Scanner

1.2

Installation Manual

DESCRIPTION

Some of the main features of this scanner are – • very high scanning speed (800 scans/s) • raster version availability • total configurability from host computer • two serial communication interfaces: one can be set as RS232, RS485, or 20-mA C.L.; the other, an RS232 auxiliary interface • readability of all popular codes • supply voltage range from 10 to 30 VDC • test mode – to verify the reading features and exact positioning of the scanner without the need for external tools. • configurability in different operating modes – to suit the most varied bar code reading system requirements. • code verifier • detection capability for absolute label position in the scan line [for digital signal processing (DSP) models only, see section 1.3] • Print contrast signal (PCS) verification (for DSP models only, see section 1.3) The LazerData 12000 Scanner uses a solid-state laser diode as a light source. The light emitted has a wavelength of between 630 and 680 nm. Refer to the section "Safety Precautions" at the beginning of this manual for information on laser safety. The use of a semiconductor laser has made it possible to develop an extremely compact scanner with low power consumption. The reader is contained in a rugged aluminum housing; the physical dimensions are 101 x 83.5 x 42 mm (4 x 3.3 x 1.7 inches) and it weighs about 800 g (1.8 lbs.). The protection class of the enclosure is IP65. The reader, therefore, is particularly suitable for industrial environments where protection against harsh external conditions is required.

1.2 - General Features

Page 14

LazerData® 12000 Scanner

Installation Manual

Electrical connection is provided through a cable on the side of the reader. This cable is terminated with a 25-pin connector (25-pin connector models, see section 1.3, Figure A, 1 ) or by a junction box (junction box models, see section 1.3, Figure B, 1 ). The laser beam output window (Figure A, 10 ) is on the right-hand side of the scanner. A green LED on the same side indicates the laser is active (Figure A, 9 ). A built-in safety system allows the laser to turn on only after the motor has reached the correct rotational speed. The laser beam is therefore generated after a slight delay from scanner power up. The four LEDs on the left-hand side of the scanner indicate the following: 3 )

indicates the reader is connected to the

POWER ON red – (Figure A, power supply

GOOD READ red – (Figure A, 4 ) is used to signal successful bar code decoding. It is also used in Test mode to signal the decoding percentage (for details refer to the section "Test Mode" in the LDHOST Help Online)

EXT TRIG yellow – (Figure A, 5 ) indicates the code presence sensor is active (for details refer to the section "On Line Mode" in the LDHOST Help Online)

TX DATA green – (Figure A, serial output line

6 ) indicates data transmission on the main

The screw holes (Figure A, 2 ) on the body of the reader are for physical attachment. The screw holes shown in Figure A, 11 are for the attachment of accessories, such as the optional 90° mirror.

General Features - 1.3

Page 15

LazerData® 12000 Scanner

1.3

Installation Manual

AVAILABLE MODELS

The LazerData 12000 Scanner is available in models with variations in the following features: •

Resolution

•

Termination of the cable

•

Distance between the scan beams (raster models only)

•

DSP (digital signal processor) or NPP (new digital preprocessor)

The following model number key illustrates the diversity of scanners available, LD 12 0 X 1 X 1 LazerData

DSP, Cannon connector

®

2

DSP, Junction Box

12000 Series 3 5-mW laser Standard resolution linear High resolution linear Std res raster pattern 1 Std res raster pattern 2

4

NPP, Junction Box

1 2 3 4

All scanner models perform 800 scans/s.

1.4 - General Features

NPP, Cannon connector

IP65 Protection Class

Page 16

Installation Manual

1.4

LazerData® 12000 Scanner

ACCESSORIES

The following LazerData 12000 Scanner accessory is available on request: •

90° deflection mirror

LD12-90DEG

General Features - 1.5

Page 17

LazerData® 12000 Scanner

1.6 - General Features

Installation Manual

Page 18

LazerData® 12000 Scanner

Installation Manual

2

INSTALLATION

2.1

PACKAGE CONTENTS

When you open the LazerData® 12000 Scanner package, ensure the following parts are included and intact: 1) 2) 3) 4) 5)

LazerData® 12000 Scanner with cable This installation manual Bar code test chart LazerData 12000 Scanner communication and utility program disk Mounting kit • Mounting screws and washers (4 ea.) • Mounting bracket (1)

*

Junction box (for junction box models only, see section 1.3) 4

3 2

5 *

1

Figure 2.1 - LazerData 12000 package contents

Installation - 2.1

Page 19

LazerData® 12000 Scanner

2.2

Installation Manual

GUIDE TO INSTALLATION

Use the following checklist to ensure a complete installation of your LazerData 12000 Scanner. 1) Read all information in the section "Safety Precautions" at the beginning of this manual. 2) Open the scanner to select the main serial interface type as required (see sections 2.3 and 2.4). 3) Correctly position and mount the scanner for bar code reading according to the information in sections 2.5, 2.8, and 3.4. 4) Provide correct system cabling according to the signals necessary (see the applicable subsections under sections 2.6 or 2.7). 5) Configure the software parameters from a host computer using either the LDHOST interface utility program provided on diskette, or using the Host Mode programming procedure by ESC sequences via the serial interface. For more details about these configuration methods refer to the section "LazerData 12000 Scanner Configuration" in the LDHOST Help Online.

NOTE Use the Test Mode, as described in LDHOST, to fine-tune the scanner position for optimum bar code reading. For further details, refer to the section "Test Mode" in the LDHOST Help Online.

The installation is now complete.

2.2 - Installation

Page 20

LazerData® 12000 Scanner

Installation Manual

2.3

OPENING THE DEVICE

Before installing the LazerData 12000 Scanner it may be necessary to open the scanner to select the interface required.

WARNING The scanner must be disconnected from the power supply during this operation.

Refer to the following instructions and diagram below when opening the reader: •

Unscrew the four screws as shown below to open the scanner for access to the output interface jumper.

•

Carefully remove the cover of the scanner. Avoid any contact with the mirrored rotor, the lenses, or other optical components.

Figure 2.2 - Opening the LazerData 12000 Scanner

Installation - 2.3