Page 41

LazerData® 12000 Scanner

Installation Manual

The WRONG output is used either for "Verifier" mode or for PCS control (PCS control is available for DSP models only, see section 1.3). For Verifier this output activates when the decoded code does not correspond to the one set in the configuration. For PCS this output activates when the PCS level is below the threshold value. USER INTERFACE

12000 Scanner

Vext 40 Vdc max

14

WRONG+

15

WRONG-

Figure 2.29 - WRONG code output connection

These outputs are all level or pulse-programmable: a 50-ms pulse is generated in the second case. Further programming information is supplied in the section "Output Lines" in the LDHOST Help Online.

2.8

POSITIONING

The LazerData 12000 Scanner is able to decode moving bar code labels at a variety of angles, however significant angular distortion may degrade reading performance. When mounting the LazerData 12000 Scanner, take into consideration these three ideal label position angles: Pitch 0° , Skew 10° to 30° and Tilt 0°. Follow the suggestions below for the best orientation: The Pitch angle is represented by the value P in Figure 2.30. Position the reader in order to minimize the Pitch angle.

2.24 - Installation

Page 42

LazerData® 12000 Scanner

Installation Manual

P

Figure 2.30 - Pitch angle

The Skew angle is represented by the value S in Figure 2.31. Position the reader to assure at least 10° for the Skew angle. This avoids the direct reflection of the laser light emitted by the LazerData 12000 Scanner. For raster models, this angle refers to the most inclined or external raster line, so that all other raster lines assure more than 10° Skew.

S

Figure 2.31 - Skew Angle

The Tilt angle is represented by the value T in Figure 2.32. Position the reader in order to minimize the Tilt angle. T

Figure 2.32 - Tilt angle

Installation - 2.25

Page 43

LazerData® 12000 Scanner

2.9

Installation Manual

TYPICAL LAYOUTS

The LazerData 12000 Bar Code Scanner was specifically designed for industrial applications. A typical use is real-time identification of moving objects on conveyor belts. A photoelectric sensor, used as a code presence sensor, signals when an object enters the scanner reading zone (see Figure 2.33). 12000 Scanner

1

Host

2

1

Main serial interface

2

Presence sensor

Figure 2.33 - LazerData 12000 typical layout

The LazerData 12000 Scanner can be mounted vertically or horizontally to read labels in the two standard positions – 'picket fence' or 'step ladder.' A system can be configured to read labels in any orientation using several scanners positioned at different angles. Allow for at least five effective scans on each bar code symbol. The number of effective scans is directly affected by the length of the scan line, scan speed, height of the bars, and code motion speed with respect to the scanner (see Section 3, “Reading Features,” for formulas you can use to compute the effective scans for your application). The possibility of using raster models allows a greater surface area of the code to be scanned, increasing the probability of correct reads even if the code printing quality is poor or the code is positioned incorrectly.

2.26 - Installation

Page 44

LazerData® 12000 Scanner

Installation Manual

2.9.1 Master-slave The master-slave layout is used to collect data from several scanners to build a multi-sided reading system; there can be one master and up to 5 slaves connected with the RS485-polled mode on the main serial interface. The master scanner is also connected to a host computer with the RS232 auxiliary interface. The P.S. signal is unique to the system; there is a single reading phase and a single message from the master scanner to the host computer. In every scanner the jumper block for the selection of the main serial interface type must be set for RS485-polled (see section 2.4). In every slave scanner the multidrop address selection must be set within the range from 0 to 4 max (see section 2.7.2 under "RS485-polled interface"). The DIP switch selections in the master scanner are ignored. 2

12000 Slave Scanner

2 1

12000 Slave Scanner

12000 Master Scanner

2

1

Auxiliary serial interface

2

Main serial interface

3

Presence sensor

3 Host

Figure 2.34 - Master-slave layout

NOTE The auxiliary serial port of the slave scanners is only used for configuration. The termination resistors of the RS485 bus must not be installed.

Installation - 2.27

Page 45

LazerData® 12000 Scanner

Installation Manual

2.9.2 Local echo In local echo mode, data is transmitted on the auxiliary interface as well as on the main interface. Host Mode programming can be accomplished either through the main interface or the auxiliary interface in local echo mode. Terminal

2

1

12000 Scanner

Host 3

1

Main serial interface

2

Auxiliary serial interface

3

Presence sensor

Figure 2.35 - Local echo layout

2.9.3 Pass through Pass through mode allows two or more devices to be connected to a single external serial interface. Each LazerData 12000 Scanner transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the host. The main and auxiliary ports are connected as shown in the figure below: 2

1

Host

12000 Scanner

3

1

3 1 2

Main serial interface Auxiliary serial interface

3

Presence sensor

Figure 2.36 - Pass through layout

2.28 - Installation

12000 Scanner

Page 46

LazerData® 12000 Scanner

Installation Manual

3

READING FEATURES

The number of reads performed by the LazerData 12000 Scanner and, therefore, the decoding capacity, is directly affected by the following factors: • scans per second • code motion speed • label dimensions • scan direction with respect to code motion At least five scans should be made of each bar code symbol, as it passes the scanner, to ensure a successful read.

3.1

STEP LADDER MODE Code Motion moving at LS speed

12000 Scanner

LH

Laser Beam

Figure 3.1 - "Step Ladder" scanning mode

If scanning is perpendicular to the code motion direction (Figure 3.1 - "step ladder" mode), the number of effective scans performed by the reader is given by the following formula SN = [(LH/LS) * SS] - 2 where, SN = number of effective scans LH = label height (in mm or inches) LS = label movement speed (in mm/s or inches/s) SS = number of scans per second

Reading Features - 3.1

Page 47

LazerData® 12000 Scanner

Installation Manual.

For example, the LazerData 12000 Scanner (800 scans/sec.), for a 25-mm high code moving at 1250 mm/s performs: SN = [(25/1250) * 800] - 2 = 14 effective scans

3.2

PICKET FENCE MODE Laser Beam Code Motion moving at LS speed

12000 Scanner

LW

FW

Figure 3.2 - "Picket Fence" scanning mode

If scanning is parallel to the code motion, (Figure 3.2 - "picket fence" mode), the number of effective scans is given by SN = {[(FW-LW)/LS] * SS} - 2 where, SN = FW = LW = LS = SS = number of effective scans reading field width (in mm or inches) label width (in mm or inches) label movement speed (in mm/s or inches/s) scans per second

For example, for a 50-mm wide code moving in a point where the reading field is 250 mm wide at a 1500 mm/s speed, the LazerData 12000 Scanner (800 scans/s), performs: SN = [((250-50)/1500) * 800] - 2 = 104 effective scans

3.2 - Reading Features

Page 48

Installation Manual

3.3

LazerData® 12000 Scanner

PERFORMANCE

The LazerData 12000 Scanner is available in four standard models varied by optical resolution characteristics (see section 1.3). The standard resolution model is a general-purpose model whose optical resolution allows code reading from 0.20- to 1.00-mm (8- to 39-mil) narrow bars in the zone between 50 and 400 mm (2.0 to 15.8 inches) from the emission window. This model can distinguish between high density codes (between 0.20 mm and 0.30 mm, or between 8 and 12 mil) and low density codes (above 0.33 mm or 13 mil) by programming the software resolution parameter (see the section "Scanner Resolution" in the LDHOST Help Online). The very high resolution model has an optical resolution that allows reading very high density codes (typical values from 0.10- to 0.20-mm, or from 4- to 8-mil, narrow bars) in the zone from 55 to 125 mm (2.2 to 4.9 inches) from the emission window. The software resolution parameter for this model should be set to high (see the section "Scanner Resolution" in the LDHOST Help Online). The Raster model R1 is a raster model used to read codes from 0.20- to 1.00-mm (8- to 39-mil) narrow bars with a raster aperture of about 12 mm (0.47 inch) at a 200-mm (7.9-inch) distance. The Raster model R2 is a raster model used to read codes from 0.20- to 1.00-mm (8- to 39-mil) narrow bars with a raster aperture of about 40 mm (1.6 inches) at a 200-mm (7.9-inch) distance. Refer to the diagrams given in paragraph 3.4 for further details on the reading features. These diagrams refer to the two standard optical models and are taken on various resolution sample codes at a 25ºC (77ºF) ambient temperature, depending on the conditions given in the notes under each diagram. If standard models do not satisfy your specific requirements, send a representative code sample of your labels to the nearest PSC Automation, Inc. distributor, who will in turn supply you with complete information on reading possibilities.

Reading Features - 3.3

Page 49

LazerData® 12000 Scanner

3.4

Installation Manual.

READING DIAGRAMS

LD12011X Scanner (Standard Resolution, 800 scans/s) NOTE: (0,0) IS THE CENTER OF THE LASER BEAM OUTPUT WINDOW 0

2

4

6

4 2 code 12 mil

0 code 8 mil

2 inches

4

CONDITIONS: Code PCS "Pitch" angle "Skew" angle "Tilt" angle SW Resolution

3.4 - Reading Features

= = = = = =

Interleaved 2/5 or Code 39 0.90 0° 10° 0° High

8

10

Page 50

LazerData® 12000 Scanner

Installation Manual

LD12011X Scanner (Standard Resolution, 800 scans/s) NOTE: (0,0) IS THE CENTER OF THE LASER BEAM OUTPUT WINDOW 0

2

4

6

8

10

12

14

16

6 4 code 20 mil 24 mil 32 mil 39 mil

2

0

2

4 inches

6

CONDITIONS: Code PCS "Pitch" angle "Skew" angle "Tilt" angle SW Resolution

= = = = = =

Interleaved 2/5 or Code 39 0.90 0° 10° 0° Low