The text of a manual · part 5 of 6
LazerData 12000 Series Bar Code Scanner Installation Manual, pages 41 to 50
Pages 41 to 50 of 58
The original document is the PDF (653 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC 12000 and Datalogic 12000
Page 41
LazerData® 12000 Scanner
Installation Manual
The WRONG output is used either for "Verifier" mode or for PCS control (PCS control is available for DSP models only, see section 1.3). For Verifier this output activates when the decoded code does not correspond to the one set in the configuration. For PCS this output activates when the PCS level is below the threshold value. USER INTERFACE
12000 Scanner
Vext 40 Vdc max
14
WRONG+
15
WRONG-
Figure 2.29 - WRONG code output connection
These outputs are all level or pulse-programmable: a 50-ms pulse is generated in the second case. Further programming information is supplied in the section "Output Lines" in the LDHOST Help Online.
2.8
POSITIONING
The LazerData 12000 Scanner is able to decode moving bar code labels at a variety of angles, however significant angular distortion may degrade reading performance. When mounting the LazerData 12000 Scanner, take into consideration these three ideal label position angles: Pitch 0° , Skew 10° to 30° and Tilt 0°. Follow the suggestions below for the best orientation: The Pitch angle is represented by the value P in Figure 2.30. Position the reader in order to minimize the Pitch angle.
2.24 - Installation
Page 42
LazerData® 12000 Scanner
Installation Manual
P
Figure 2.30 - Pitch angle
The Skew angle is represented by the value S in Figure 2.31. Position the reader to assure at least 10° for the Skew angle. This avoids the direct reflection of the laser light emitted by the LazerData 12000 Scanner. For raster models, this angle refers to the most inclined or external raster line, so that all other raster lines assure more than 10° Skew.
S
Figure 2.31 - Skew Angle
The Tilt angle is represented by the value T in Figure 2.32. Position the reader in order to minimize the Tilt angle. T
Figure 2.32 - Tilt angle
Installation - 2.25
Page 43
LazerData® 12000 Scanner
2.9
Installation Manual
TYPICAL LAYOUTS
The LazerData 12000 Bar Code Scanner was specifically designed for industrial applications. A typical use is real-time identification of moving objects on conveyor belts. A photoelectric sensor, used as a code presence sensor, signals when an object enters the scanner reading zone (see Figure 2.33). 12000 Scanner
1
Host
2
1
Main serial interface
2
Presence sensor
Figure 2.33 - LazerData 12000 typical layout
The LazerData 12000 Scanner can be mounted vertically or horizontally to read labels in the two standard positions – 'picket fence' or 'step ladder.' A system can be configured to read labels in any orientation using several scanners positioned at different angles. Allow for at least five effective scans on each bar code symbol. The number of effective scans is directly affected by the length of the scan line, scan speed, height of the bars, and code motion speed with respect to the scanner (see Section 3, “Reading Features,” for formulas you can use to compute the effective scans for your application). The possibility of using raster models allows a greater surface area of the code to be scanned, increasing the probability of correct reads even if the code printing quality is poor or the code is positioned incorrectly.
2.26 - Installation
Page 44
LazerData® 12000 Scanner
Installation Manual
2.9.1 Master-slave The master-slave layout is used to collect data from several scanners to build a multi-sided reading system; there can be one master and up to 5 slaves connected with the RS485-polled mode on the main serial interface. The master scanner is also connected to a host computer with the RS232 auxiliary interface. The P.S. signal is unique to the system; there is a single reading phase and a single message from the master scanner to the host computer. In every scanner the jumper block for the selection of the main serial interface type must be set for RS485-polled (see section 2.4). In every slave scanner the multidrop address selection must be set within the range from 0 to 4 max (see section 2.7.2 under "RS485-polled interface"). The DIP switch selections in the master scanner are ignored. 2
12000 Slave Scanner
2 1
12000 Slave Scanner
12000 Master Scanner
2
1
Auxiliary serial interface
2
Main serial interface
3
Presence sensor
3 Host
Figure 2.34 - Master-slave layout
NOTE The auxiliary serial port of the slave scanners is only used for configuration. The termination resistors of the RS485 bus must not be installed.
Installation - 2.27
Page 45
LazerData® 12000 Scanner
Installation Manual
2.9.2 Local echo In local echo mode, data is transmitted on the auxiliary interface as well as on the main interface. Host Mode programming can be accomplished either through the main interface or the auxiliary interface in local echo mode. Terminal
2
1
12000 Scanner
Host 3
1
Main serial interface
2
Auxiliary serial interface
3
Presence sensor
Figure 2.35 - Local echo layout
2.9.3 Pass through Pass through mode allows two or more devices to be connected to a single external serial interface. Each LazerData 12000 Scanner transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the host. The main and auxiliary ports are connected as shown in the figure below: 2
1
Host
12000 Scanner
3
1
3 1 2
Main serial interface Auxiliary serial interface
3
Presence sensor
Figure 2.36 - Pass through layout
2.28 - Installation
12000 Scanner
Page 46
LazerData® 12000 Scanner
Installation Manual
3
READING FEATURES
The number of reads performed by the LazerData 12000 Scanner and, therefore, the decoding capacity, is directly affected by the following factors: • scans per second • code motion speed • label dimensions • scan direction with respect to code motion At least five scans should be made of each bar code symbol, as it passes the scanner, to ensure a successful read.
3.1
STEP LADDER MODE Code Motion moving at LS speed
12000 Scanner
LH
Laser Beam
Figure 3.1 - "Step Ladder" scanning mode
If scanning is perpendicular to the code motion direction (Figure 3.1 - "step ladder" mode), the number of effective scans performed by the reader is given by the following formula SN = [(LH/LS) * SS] - 2 where, SN = number of effective scans LH = label height (in mm or inches) LS = label movement speed (in mm/s or inches/s) SS = number of scans per second
Reading Features - 3.1
Page 47
LazerData® 12000 Scanner
Installation Manual.
For example, the LazerData 12000 Scanner (800 scans/sec.), for a 25-mm high code moving at 1250 mm/s performs: SN = [(25/1250) * 800] - 2 = 14 effective scans
3.2
PICKET FENCE MODE Laser Beam Code Motion moving at LS speed
12000 Scanner
LW
FW
Figure 3.2 - "Picket Fence" scanning mode
If scanning is parallel to the code motion, (Figure 3.2 - "picket fence" mode), the number of effective scans is given by SN = {[(FW-LW)/LS] * SS} - 2 where, SN = FW = LW = LS = SS = number of effective scans reading field width (in mm or inches) label width (in mm or inches) label movement speed (in mm/s or inches/s) scans per second
For example, for a 50-mm wide code moving in a point where the reading field is 250 mm wide at a 1500 mm/s speed, the LazerData 12000 Scanner (800 scans/s), performs: SN = [((250-50)/1500) * 800] - 2 = 104 effective scans
3.2 - Reading Features
Page 48
Installation Manual
3.3
LazerData® 12000 Scanner
PERFORMANCE
The LazerData 12000 Scanner is available in four standard models varied by optical resolution characteristics (see section 1.3). The standard resolution model is a general-purpose model whose optical resolution allows code reading from 0.20- to 1.00-mm (8- to 39-mil) narrow bars in the zone between 50 and 400 mm (2.0 to 15.8 inches) from the emission window. This model can distinguish between high density codes (between 0.20 mm and 0.30 mm, or between 8 and 12 mil) and low density codes (above 0.33 mm or 13 mil) by programming the software resolution parameter (see the section "Scanner Resolution" in the LDHOST Help Online). The very high resolution model has an optical resolution that allows reading very high density codes (typical values from 0.10- to 0.20-mm, or from 4- to 8-mil, narrow bars) in the zone from 55 to 125 mm (2.2 to 4.9 inches) from the emission window. The software resolution parameter for this model should be set to high (see the section "Scanner Resolution" in the LDHOST Help Online). The Raster model R1 is a raster model used to read codes from 0.20- to 1.00-mm (8- to 39-mil) narrow bars with a raster aperture of about 12 mm (0.47 inch) at a 200-mm (7.9-inch) distance. The Raster model R2 is a raster model used to read codes from 0.20- to 1.00-mm (8- to 39-mil) narrow bars with a raster aperture of about 40 mm (1.6 inches) at a 200-mm (7.9-inch) distance. Refer to the diagrams given in paragraph 3.4 for further details on the reading features. These diagrams refer to the two standard optical models and are taken on various resolution sample codes at a 25ºC (77ºF) ambient temperature, depending on the conditions given in the notes under each diagram. If standard models do not satisfy your specific requirements, send a representative code sample of your labels to the nearest PSC Automation, Inc. distributor, who will in turn supply you with complete information on reading possibilities.
Reading Features - 3.3
Page 49
LazerData® 12000 Scanner
3.4
Installation Manual.
READING DIAGRAMS
LD12011X Scanner (Standard Resolution, 800 scans/s) NOTE: (0,0) IS THE CENTER OF THE LASER BEAM OUTPUT WINDOW 0
2
4
6
4 2 code 12 mil
0 code 8 mil
2 inches
4
CONDITIONS: Code PCS "Pitch" angle "Skew" angle "Tilt" angle SW Resolution
3.4 - Reading Features
= = = = = =
Interleaved 2/5 or Code 39 0.90 0° 10° 0° High
8
10
Page 50
LazerData® 12000 Scanner
Installation Manual
LD12011X Scanner (Standard Resolution, 800 scans/s) NOTE: (0,0) IS THE CENTER OF THE LASER BEAM OUTPUT WINDOW 0
2
4
6
8
10
12
14
16
6 4 code 20 mil 24 mil 32 mil 39 mil
2
0
2
4 inches
6
CONDITIONS: Code PCS "Pitch" angle "Skew" angle "Tilt" angle SW Resolution
= = = = = =
Interleaved 2/5 or Code 39 0.90 0° 10° 0° Low