GROUP-1
INTERFACES SELECTION, COMPUTER TYPE, DEFAULT, SCAN SPEED.
- A001 Desa IN
.co04s
PC-AT
COMPUTER TYPE i NOTEBOOK*
SYMPTOMS SOLUTION i Scanner seems to be | 1. Unplug the cable from the host computer.
i performing as usual, | 2. Plug the cable back into the host computer. i : but no data is being | 3. Set the scanner to the exact computer type i output. immediately.
Caution:Please ensure the correct computer type is set when the scanner is attached to a new host computer. If set to Notebook, the scanner will operate with no external keyboard.
_coo1s INTERFACES SELECTION IMA
. coozs Keno MAINA
RS232
. co03g
TT
END MAME USB
SYMPTOM SOLUTION
The wand does not 1. Unplug the cable from the host computer. scan/ The scanner 2. Plug the cable back into the host computer. does not scan when | 3. Set the wand to the correct interface. The the trigger is cable needs to match the interface. depressed.
Caution: This scanner is designed to switch easily between interface options. To switch from one interface to another, the appropriate cable must be installed. After changing to a new cable, be sure to reset the interface setting as appropriate.
Page 12
GROUP-2
READING MODE SETTING
Fooss
CONTINUOUS MODE
Fools
FLASH MODE
TRIGGER MODE
. FOOSS
CONTINUOUS AUTO OFF
Fou3$
TOGGLE MODE
» FOO7S
*AUTO SENSING MODE
*ULTRAVIOLET MODE
Foo4s
TEST MODE
NOTES:
B oN os
On
. To extend the scanner's life,
* LED is always on. , * The trigger does not function in Continuous Mode.
*The LED is on steadily if a bar code is close to the scanner, but starts to flash if no bar code has been detected after 60 seconds.
*The trigger does not function in Flash Mode.
* The LED will light when the trigger is pressed.
* The LED will go off when the trigger is released.
* The LED is always on when the trigger is pressed .
* The LED will go off if no bar code has been detected after 60 seconds.
* This function works like Trigger Mode, but the scanner beeps to indicate a good read.
* If Auto-Sensin, (Triggerless) Mode is on, the LED will go offi the scanner does notdetect a bar code.
The LED lights automatically when a bar code is detected.
* If Ultraviolet Mode is on, the ultraviolet light source will light and stay on continuously.
* The ultraviolet light will go off when the trigger is pressed, and back on when the trigger is released.
* Factory Test Scanning keep the scanner set to Trigger Mode or
Continuous Auto Off Mode.
Only certain models support Auto Sensing or Ultraviolet Modes. For convenience, print the bar code for Ultraviolet Mode and keep it near the work station for easy scanning when needed.
swift from Ultraviolet Mode The LED will glow RED for
In Ultraviolet Mode, press the trigger button and the reading mode will to the reading mode the scanner was last in. STANDBY and GREEN for GOOD READ.
The Trigger Mode is available for most handheld bar code scanner, but
The trigger is only available to wands with a switch capability.
10
Page 13
Autosensing Mode : I Autosensing Mode:ON .F007$
Autosensing Mode When Autosensing Mode is on, both Blue LED and Magnetic switches will be on automatically (Blue LED ON + Magnetic switches ON).
Magnetic ON/OFF .F034$
Magnetic Switch ON .F035$
Magnetic Switch OFF Remark: (1). Be informed that Magnetic Switch functionality is offered for certain high grade model only, please consult your vendor for the detail, (2). It should be paired to work with Magnetic Stand. (3). If Magnetic Switch is on, the scanner will be switched to Autosensing mode while you put it on the Autostand. the scanner will be switched to Trigger mode while move away from autostand.
Enhanced CCD autosensing ( Blue LED) : ON/OFF .F032$
BLUE LED ON .F033$
Blue LED OFF Blue LEDs are enhanced the sensitivity of Autosensing mode. If Blue LEDs are on, the Sensitivity of autosensing will be become more sensitive.
11
Page 14
Autosensing Mode : ll No decode timeout (3sec) .F030$
No decode timeout ( 3sec) No decode timeout The purpose is to control the illumination red LED, if no any signal detect within setting time, the Illumination Red LED turn will turned off. The greater the number, the longer time. Setting procedures: Step 1 scan No decode timeout Step 2 scan two digits from numeric table Step 3 scan No decode timeout.
0
1
2
3
4
5
6
7
8
9
12
Page 15
GROUP-3
CHECK VERSION, BEEP TONE , TERMINATOR SEND DATA LENGTH
BEEP TONE MODE 2.7KHz
-FOISS
BEEP HIGH
-FO21$
BEEP HIGH--LOW
.FO18$ BEEP MEDIUM -FO20%
BEEP LOW--HIGH
-FO225
BEEP LOW
2.1KHz
. FO1Z$
BEEP OFF
WM BEEP HIGH wai
BEEP HI LOW
BEEP MEDIUM eeu
BEEP LOW--HIGH
WANN BEEP LOW LT
CHECK VERSION
TERMINATOR, WU NINICTeaa ee WTO
.po11g TAB .pO15s " IAN
‘ANTI SPACE
A re cr AIIM ESC
NOTES:
1. For the Keyboard Wedge interface the default terminator is CR.
2. For the USB interfaces the default terminator is CR,
3. For the RS232 interfaces the default terminator is CR+LF
SEND DATA LENGTH
-DO19$ A eee (101,01
SEND DATA LENGTH OFF
13
CHECK VERSION
Page 16
GROUP-4
SETUP CODE READ, PREAMBLE & POSTAMBLE.
SETUP CODE READ
BOSS ee meses TANI
SETUP CODE OFF x 1
NOTE : * 1 This setting is disable to all User's Manual Code setting. To use bar code setting, Scan Setup Code On enable bar code setting.
PREAMBLE & POSTAMBLE ( PREFIX AND SUFFIX )
ii ll {| | | | | | CLEAR PRE/ POSTAMBLE iil ll {| | | | | |
PREAMBLE (16)
. AD13$
POSTAMBLE (16)
EXAMPLE: Set PREAMBLE String as" ##" POSTAMBLE String as " $$"
SETTING PROCEDURE:
STEP 1 : Scan : CLEAR PRE/ POSTAMBLE. STEP 2: Scan : PREAMBLE.
STEP 3: Scan :"#" twice from FULL ASCII Table. STEP 4 : Scan : PREAMBLE.
STEP 5: Scan : POSTAMBLE.
STEP 6 : Scan :"$" twice From FULL ASCII Table. STEP 7 : Scan : POSTAMBLE.
FORMAT: { Preamble}{CodelD}{Bar Code}{Postamble}
NOTES:
1. APREAMBLE is a string of up to 16 characters added to the beginning of a scanned barcode.
2. APOSTAMBLE is a string of up to16 characters added to the end of a scanned bar code.
3. Default value for either: None.
14
Page 17
GROUP-5
ACCURACY ADJUSTMENT Oo 5 | | 6 , | 7 3 | 8 4 | LW . AD10$ ACCURACY ADJUSTMENT
Accuracy Adjustment assures a more reliable decoded output. Enabling the feature and setting a number from 1 to 9 subjects the decoded output a higher standard of accuracy. The higher the number, the greater the accuracy.
SETTING PROCEDURE:
1. Scan ACCURACY ADJUSTMENT.
2. Scan one digit ( 1~9) from barcode menu above. 3. Scan ACCURACY ADJUSTMENT.
- PO2Z3
NOTES:
1. The scanner will beep three times as reminder that a setting is not yet complete.
2. If you make a mistake, forget a step, etc., scan RESET to start again.
15
Page 18
GROUP-6
LABEL TYPE POSITIVE / NEGATIVE, ENABLE AND DISABLE CODE ID ee TYPE POSITIVE / NEGATIVE
ABLE NEGATIVE (Postive LABEL ENABLE)
-bo22$
ENABLE NEGATIVE LABEL (POSITIVE & NEGATIVE ENABLE)
ENABLE CODE ID
. ADOBSs
FACTORY ID ON iii ll | | | | | | AIM ID ON iil ll {| | | | | |
SET ID -ON
DISABLE CODE ID
. ADDSS
NOTES:
1. Only ONE code ID will be sent.
2. The code ID is located at the position before the bar code data and after the preamble.
EXAMPLE :
1.Preamble 145287,
2.Code ID: enable AIM ID,
3.Bar code symbologies : EAN 13+5
4'563987"123453 12411 Preamble CODE ID BARCODE / DATA 145287 AIM ID : JEO EAN 13 +5
OUTPUT, : 145287]E0456398712345312411
16
Page 19
GROUP-7
SYMBOLOGIES CODE ID IDENTIFIER, SET ID
SYMBOLOGIES CODE ID IDENTIFIER . Factory | AIM ID . Factory | AIM ID Symbologies Symbologies yon ID | (new) yore ID | (new) EAN 128 T JCl_ | Msi 0 JMO Code 128 K JCO | MSI(MOD 10/ CDV & not send CD) yM1 EAN8(+2/+5 OFF) JE4, |Code 32 B 1x0 EAN8(+2 ON) s TE4 | Codabar IFO BAN8(+5 ON) JE4, |Codabar(ABC Codabar) N |FI UPC-E(+2/+5 OFF) JEO = |Codabar(CDV & Send CD) ]F2 UPC-E(+2 ON) E JE3 _ [Codabar(CDV & not send CD) 1F4 UPC-E(+5 ON) ]E3 _ |UK Plessey P JP0 UPC-A(+2/+5 OFF) JEO = [Matrix 2 of 5 Y ]x0 UPC-A(+2 ON) A JE3 _ |Full ASCII Code 39(disable CDV) ]A4 UPC-A(+5 ON) JE3 |Full ASCII Code 39(CDV & send CD)|_ _D JA5 EAN-13(+2/+5 OFF) JEO Full ASCII Code 39(CDV & not send CD) JA7 EAN-13(+2 ON) F JE3 _ |Standard Code 39(disable CDV) JA0 EAN-13(+5 ON) JE3 | Standard Code 39(CDV & send CD) M JAl Code 93 L ]G0 Standard Code 39(CDV & not send CD) JA3 Code 11 (disable CDV) JHO _ |IATA2 of 5 R JRO Code 11(send one CD) 1 JHO Industrial 2 of 5 Vv ]So Code 11(send two CD) JH1 {China Post Code H ]x0 Code 11(not send CD) JH3, |interleaved 2 of (CDV & send CD) it Telepen(ASCII) JBO _ Interleaved 2 of (CDV & not send CD) I 13 Telepen(Numeric) U ]B1 Interleaved 2 of 5(disable CDV) j10
SET ID - SETTING PROCEDURES
Settting steps:
1. Scan the SET ID bar code for a particular symbology.
2. Scan one or two alphanumeric characters from the Full ASCII Table. 3. Scan the SET ID bar code again.
Example :Define the MSI Code ID = A, Code 93 = G9
MSI:
Step1: Scan MSI Set ID (Group 9).
Step2: "A" from (Group 37).
Step3: Scan MSI Set ID (Group 9).
Code 93:
Step1: Scan Code 93 Set ID (Group 8). i Step2: "G" from (Group 38), Scan "9" from(Group 42). .. Step3: Scan Code 93 Set ID (Group 8).
NOTES:
1. The length of a Code ID is either one or two characters. If one character is set, the Code ID output will be one character. If two charact
17
Page 20
GROUP-8
CODE ID CONFIGURATION: SET ID
- POO1s AMAIA . POOZS AMANO . Poo3ss AMIN A . Poo4ss INIA - POOSS IMAI A -PO13S IAIN A . POOTS AMINA - PO2Z1$ INIT - PO1OS IMAM A . PO16S IMAM A . PO22s$ IAIN MA . PooSs INI A ~PO11S IMINO
18
EAN 13 Set ID
EAN 8- Set ID
UPC E Set ID
UPC A Set ID
CODE 39 Set ID
Code 93 Set ID
Codabar Set ID
IATA Set ID
Code 128 Set ID
EAN1 28 Set ID
Telepen Set ID
Code 11 Set ID
Code 32 Set ID