The text of a manual · part 1 of 8
Barcode Scanner User's Manual: Installation and Programming Guide, pages 1 to 10
Pages 1 to 10 of 76
The original document is the PDF (14 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the POS-X Xi3200
Page 1
BARCODE SCANNER USER’S MANUAL
Installation and Programming Guide
Version 1.4
WWW.POS-X.cOom
Page 2
Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices). FCC Radiation Exposure Statement
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Page 3
Preface 6-8 7 8
(Appendix Autosensing)
9 10-12
, Setup Code ON/OFF
2
Code 39 (Full ASCII/STANDARD), Code 32
C
EXPAND
49 50 51
DataBar (RSS) 33 STMBOLOGIE:PDF417
4 34~42 43~45 46~48
8 52-60 61-63 64-66 67-69 70-71 72-73
1
Page 4
2
The following manual applies to all POS-X , XI3200 series and EVO series barcode scanners. For additional help, please visit www.pos-x.com or call POS-X technical support.
Page 5
Figure 2
Kind of Troubles
Symptoms
Solutions
Computer Type ( Group 1)
Scanner seems to be performing as usual, but no data is being output.
. Unplug the cable from the host computer. . Plug the cable back into the host computer. . Set the scanner to the exact computer type immediately.
“NG
Interfaces Selections ( Group 1)
The scanner does not scan when the trigger is depressed.
Unplug the cable from the host computer.
. Plug the cable back into the host computer.
. Set the scanner to the correct interface. The cable needs to match the interface., NO
Setting Procedure have not completed ( Setting Need Triple
Shot scanning ) Group - 4,5,8,9, 17, 18, 19,20,22,23,25, 31
Most settings require only a single bar code , but a few need several different bar codes to be scanned in order to completely define a setting. They are:
1. Preamble, Postamble (Group 4) (page 14)
2.Accuracy Adjustment (Group 5) (page 15)
3. Customer ID Configuration (Groups 8 and 9)(page 18-19)
4. Min/Max Length (Groups 17, 18, 19, 20, 21, 22,25)
5. ABC Codabar (Groups 22)
6. CX-Codabar (Groups 22 and 23)
7. Coupling Codabar (Groups 22 and 23)
8. EAN 128 (Group 31)
. Follow the procedures for these settings at the appropriate pages.
. The scanner will beep three times for an incomplete setting.
. Scan RESET to try a setting again.
N oO
Limitation of length of the bar code
The scanner is reading correctly, except for certain bar codes ofa certain length
Reset the Min/Max setting for the bar code symbology affected.
RS232 Protocol Comunication set problem
The scanner appears to be working in the RS-232 interface, but no datais output.
Ensure the correct RS-232 communication parameters have been set: Baud Rate, Handshaking, Stop Bits, Data Bits, andParity. These settings must be the same for both the scanner and the host.
Page 6
CLONING MODE
WHAT IS CLONING MODE? CLONING duplicates a scanners settings in other scanners. It can save time when a number of scanners must be programmed to the same settings.
HOW SHOULD CLONING WORK?
. Using this guide, make all the necessary settings for one wand.
. Scan the CLONING MODE bar code shown below.
. When CLONING MODE is scanned, all setup parameters will be converted to alphanumeric characters and shown on the monitor.
4. Using a bar code printer, print out all the setup parameters as Code 39 bar code labels.
. Scan the printed labels sequentially with each wand to be programmed.
wn a
AAT 2c . A018 IRIAN | 2m.
.A018$( Cloning Mode on PC/AT) - you can clone the settings to a PC/AT regardless what kind of device has been chosen on the scanner
NOTES:
. All cloning strings are upper case.
. All cloning strings printed on labels should be the same as those on the monitor sequentially from first to last.
Cloning mode works in Word Note Pad only.
Never edit the data on the first row (.A017$). Itis an entry gate for cloning.
. The cloning string's length can be adjusted by combining multiple strings into one, or by breaking one string to multiple strings starting from the second row after "....". Length must be in sequences of four, such as 4,8,12,16,20 (MAX).
6. Be sure to print the dots exactly where they are shown on the monitor.
a Re No
FORMAT OF CLONING
* Format of Cloning : 1st rows >>> ".A017$"( never edit any data of the first row ) 2nd rows >>> "...XXXX" you can adjust the String's Length starting from the dots”...." forward. The length of the string should be in 4, 8,12,16 or 20 ( MAX )digits. 3rd rows~ so on >>> XXXX End rows- A dot "." Is an ending of cloning.
XXXX Stand for any String
Page 7
EXAMPLE :
1. PROJECT ASSIGNMENTS :
1.1. Beep tone: BEEP LOW -- HIG
1.2. Capslock Mode: CAPSLOCK On FIXED ). 1.3. Reading Mode: CONTINUOUS AUTO OFF.
2. SETTING PROCEDURE: Scan BEEP LOW.--HIGH (GROUP 3 (pages) 5 2 Scan CAPSLOCK ON (FIXED).(GR' Ph: 2.3. Scan CONTINUOUS AUTO OFF. (SROU 2).(page12)
3. All parameters will be converted to alphanumeric characters and shown on the monitor.
.A017$ ....0604 eS FE 5A025F04
4. Print the results shown on the monitor as bar codes with a bar code printer. The bar codes should be in the Code 39 symbology.
iii ll | | | | | |
5. Scan these labels with any of the wands that must be programmed with the same settings as the first wand. Be sure to scan from the first row to the second and so on sequentially, top to bottom.
CORRECT SETTING
-A017$ weet 4 -A017! 0604 4 y 5A02 4 -+-06045A02 12 5F04 4 5F04. ; . (Dot) 4+.( Dot) WRONG SETTING -A017$, - - 4 Wrong Setting: The string”...." 0604 Consists of 4 Dots, located at the 5A02 beginning of second rows, Do not 5F04 break the "...." Into multiple string. .A017$ YY“ Wrong Setting: The string lengths in the 06045 9x second and third rows do not match the = 7x }+« length requirements, because rows should A025F04 be in lengths of four digits. . . (Dot) ~ + - _« il A017$.... x « wrong nang you add 0604 The 0.A17$ is a FIXED parameter for 5A02 4uv setup entering. It is an unchangeable 5F04. 4+.(Dot) ~ parameter. Never adds, delete or rearrange data from the FIRST row.
Page 8
HOW TO CONNECT THE SCANNER TO THE HOST TERMINAL: Handheld Barcode Scanner
KEYBOARD WEDGE INTERFACE
1. Power down the host computer.
2. Disconnect the keyboard cable from the computer.
3. Connect the "Y" cable between the keyboard and the scanner and the computer.
4. Restart the computer.
5. The scanner will beep.
6. Set the scanner to KEYBOARD interface by referring to GROUP 1 (page11) (Interface Selections).
7. Scanner will beep to confirm the setting.
8. Scan a bar code to confirm that data shows on the monitor.
Connect to PC- Computer e Connect to Keyboard Port Barcode Scanner (Rj45)
Connect to Keyboard
RS-232 INTERFACE
1.Power down the host computer.
2.Connect the RS-232 cable between the scanner and the computer.
3 Connect the power adaptor to the cable.
4 Restart the computer, .
5.Plug the power adaptor into a power outlet.
6.The scanner will beep.
7.Set the scanner to RS-232 interface by referring to GROUP 1 (page 11) (Interface Selection).
8.Set RS-232 protocol: Baud Rate, Stop Bits, Handshaking, Data Bits, and Parity.
9.Scan a bar code to confirm that data shows on the monitor.
NOTES:
1.Before plugging the power adaptor into the scanner, be sure the voltage, power consumption, and inner and outer DC characteristics are correct to avoid serious damage to the scanner and/or the computer.
2.Make sure the protocol communication settings of the scanner (such as baud rate, data bits, etc.) match those of the host computer. Otherwise, no data will be
. transmitted.
Connect to the bar code scanner Connectto the (Rj45 connector) Serial port of PC terminal
Connect the Power-jack of power adaptor rf Check the power adaptor to ensure: \ H 1. Input of AC current 110V/ 220V matches the power H | supply standard of the country in which the scanner ! | is being used. | ! 2.Adapter output is +5V DC & i \ 3.The jack input is +5V DC /
Page 9
USB INTERFACES
The USB Interface supported is compatible with the Apple MAC series, later PCs and Windows 98, 2000, Me and XP, Vista .
1. Connect the USB cable between the scanner and the computer.
2. The scanner will beep.
3. The Scanner will detect the USB driver automatically. (The first time the scanner is connected via the USB port, follow the appropriate instructions for the host computer.)
4. Set the scanner to KEYBOARD/USB interface by referring to
GROUP-1 (Interface Selections). 5. Scanner will beep to confirm the setting. 6. Scan a bar code to confirm that data shows on the monitor.
HOW TO CHANGE
The CCD scanner are designed to switch easily between interface options. To switch from one interface to another, the appropriate cable must be installed. To change a cable, simply follow these steps:
1.To release the cable, insert a pin or straightened paper clip into the hole at the base of the scanner where the cable is connected.
2. Remove the cable from the scanner.
3. Plug in the new cable.
After changing to a new cable, be sure to resetthe interface setting as appropriate (including parameter settings for the RS-232 interface).
New Cable
6 < - Skea
Present cable
0 0 > Sken - - New Cable
008, -ca
Present cable
Page 10
HOW TO SET PARAMETERS
How do you program a scanner with this user's guide?
1. Use the scanner to scan at the bar code representing the function/ parameter you want to set.
ND
. When you hear two beeps, the new setting will have been defined or updated into the memory processor.
Default parameters are indicated in bold type and underlined characters. The character font is ARIAL BLACK. CD = Check Digit. CDV = Check Digit Verification.
Most settings require only a single bar code, but a few need several different bar codes to be scanned in order to completely define a setting. They are:
== SETTINGBARCODE =o
Preamble / Postamble (maximum 16 digits)
Step 1: Scan CLR PRE/POSTAMBLE.
Step 2: Scan PREAMBLE or POSTAMBLE..
Step 3: Scan any alphanumeric from Full ASCII Table in Groups 34 - 45, (page52-63) Step 4: Scan PREAMBLE or POSTAMBLE.
Min Length/ Max Length
Step 1: Scan MIN LENGTH or MAX LENGTH. Step 2: Scan two digits from Group 42 (page60) Step 3: Scan MINLENGTH or MAX LENGTH.
Accuracy Adjustment
Step1: Scan ACCURACY ADJUSTMENT. Step 2:Scan one digit from Group 42 (page60) Step 3:Scan ACCURACY ADJUSTMENT.
Customer Configuration ID (Example: Code 39 )
Step 1: Scan CODE 39 SET ID from Group 8. (page18)
Step 2: Scan either one digits or two digits alphanumeric (maximum 2 digits) from Full ASCII table In Groups 34 - 45. (page52-63)
Step 3: Scan CODE 39 SET ID from Group 8.(page18)
Set A Data - (CX-Codabar, ABC Codabar, Codabar Coupling).
Step1: Scan SETADATA.
Step 2:Scan one digits any alphanumeric character from Full ASCII Table in Groups 34 - 45, (page52-63)
Step 3: Scan SETADATA.
NOTES:
1. The scanner will beep three times as a reminder that a setting is not yet complete.
2. If you make a mistake, forget a step, etc., scan CLEAR to start again.
sili) ll tl l | | | ll
\H------~!