The text of a manual · part 2 of 3
Xi3000 Scanner User's Manual, pages 10 to 18
Pages 10 to 18 of 25
The original document is the PDF (301 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the POS-X Xi3000
Page 10
• Plessey
• EAN8 Enable
< Enable No Addon > < Disable >
Disable No Addon
• UPCA Enable Addon2
< Disable Addon2 >
< Enable No Addon > Enable Addon5
Disable No Addon
< Disable Addon5 >
Enable Addon2
• EAN13 < Disable Addon2 >
Enable Addon5
< Enable No Addon > < Disable Addon5 >
Disable No Addon
• UPCE
Enable Addon2 < Disable Addon2 >
< Enable No Addon > Enable Addon5 Disable No Addon < Disable Addon5 > Enable Addon2 < Disable Addon2 > Enable Addon5 < Disable Addon5 >
Update
17
18
Enter Setup
Page 11
Code39 Parameters
French Pharmacode Parameters
• Standard / Full ASCII Code39
• Checksum Transmission
< Standard >
< Enable > Full ASCII
Disable
• Start / Stop Transmission
Industrial 25 Parameters • Start / Stop Selection
Enable < Disable >
< Industrial 25 >
• Checksum Verification
Interleave 25 Matrix 25
Enable
• Checksum Verification
< Disable >
• Checksum Transmission Enable < Disable >
< Enable >
• Checksum Transmission
Disable
Italy Pharmacode Parameters
< Enable >
• Checksum Transmission
Disable
< Enable > Disable>
Update
19
20
Enter Setup
Page 12
• Checksum Verification
• Max / Min Code Length Qualification
Enable
Select Max / Min Length Qualification
< Disable >
• Checksum Transmission
Max Length * Min Length *
< Enable >
• Fixed Code Length Qualification
Disable
• Max / Min Code Length Qualification
Select Fixed Length Qualification
Select Max / Min Length Qualification
Fixed Length 1 * Fixed Length 2 * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.
Max Length * Min Length * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.
Interleave 25 Parameters • Start / Stop Selection
Industrial 25 < Interleave 25 > Matrix 25
Update
21
22
Enter Setup
Page 13
• Max / Min Code Length Qualification
• Fixed Code Length Qualification
Select Max / Min Length Qualification
Select Fixed Length Qualification
Max Length *
Fixed Length 1 *
Min Length *
Fixed Length 2 * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.
• Fixed Code Length Qualification
Select Fixed Length Qualification
Matrix 25 Parameters • Start / Stop Selection
Fixed Length 1 * Fixed Length 2 * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.
Industrial 25 Interleave 25 < Matrix 25 >
Codabar Parameters
• Checksum Verification
• Start / Stop Transmission
Enable Enable < Disable > < Disable >
• Checksum Transmission
< Enable > Disable
Update
23
24
Enter Setup
Page 14
• Start / Stop Selection
MSI Parameters • Checksum Verification
< abcd / abcd > abcd / tn*e
< Single Modulo 10 >
ABCD / ABCD
Double Modulo 10 ABCD / TN*E
Modulo 11 & 10
• Checksum Transmission
Plessey Parameters • Convert to UK Plessey
< Last digit not Transmitted > Transmitted
Enable Last 2 Digits not Transmitted < Disable >
• Max / Min Code Length Qualification
• Checksum Transmission
Select Max / Min Length Qualification
< Enable > Disable
Max Length * Min Length * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.
Update
25
26
Enter Setup
Page 15
• Fixed Code Length Qualification
EAN8 Parameters • Convert to EAN13
Select Fixed Length Qualification Enable Fixed Length 1 *
< Disable >
• Checksum Transmission
Fixed Length 2 * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.
< Enable > Disable
EAN128 Parameters • Field Separator
UPCA Parameters • Convert to EAN13
* Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 45. One character consists of 2 hexadecimal digits. If keyboard interface is used, the associate key type/status can also be specified. The associate key type/status (if specified) must be selected before each character being programmed. (3) Read the “Validate” label (also on page 45) to complete this setting.
< Enable > Disable
• System Number Transmission
< Enable > Disable
• Checksum Transmission
< Enable > Disable
Update
27
28
Enter Setup
Page 16
UPCE Parameters
EAN13 Parameters
• System Number Selection
• ISBN Conversion
System Number 0 and 1
Enable < System Number 0 only >
< Disable >
• Convert to UPCA
• ISSN Conversion
Enable
Enable < Disable >
< Disable >
• System Number Transmission
• Checksum Transmission
Enable
< Enable > < Disable >
Disable
• Checksum Transmission
< Enable > Disable
Update
29
30
Enter Setup
Page 17
Activate Editing Formats
Editing Format Parameters
• Format 1
• Format Selection
Enable
Format 1 < Disable >
Format 2
• Format 2
Format 3
• Restore Default Format
Enable < Disable >
• Format 3
Enable < Disable >
• Exclusive Data Editing
Yes < No >
Update
31
32
End of Format Programming
Page 18
• Applicable Data Length
• Total Number of Fields
Maximum Length *
1 Minimum Length *
4
Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.
2 5
• Matching String of Applicable Data
3 6
* Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 45. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 45) to complete this setting.
• Location of Matching String * Programming Instructions : (1) Read the label. (2) Program the desired location by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.
Update
33
34
End of Format Programming