Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 3

Xi3000 Scanner User's Manual, pages 1 to 9

Pages 1 to 9 of 25

The original document is the PDF (301 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the POS-X Xi3000

Page 1

Table of Contents

Xi3000 Scanner

User’s Manual

Restore Default Settings............................................................................. 1 Exit Setup without Changes....................................................................... 1 Configure Through RS232......................................................................... 1 List Setting .................................................................................................. 1 Buzzer Settings............................................................................................ 2 Reading Redundancy Setting .................................................................... 2 Scan Mode Setting ...................................................................................... 3 Scanner Time-out Duration....................................................................... 3 Negative Barcode Setting ........................................................................... 3 Delay between Reread ................................................................................ 4 Keyboard Wedge Parameters.................................................................... 4 RS-232 Parameters ..................................................................................... 8 Prefix / Postfix Settings ............................................................................ 10 Character Substitution............................................................................. 10 Code ID Selection ..................................................................................... 10 Code ID Setting......................................................................................... 11 Length Code Setting (2 digits) ................................................................. 12 Select Readable Codes.............................................................................. 15 Code39 Parameters .................................................................................. 19 Italy Pharmacode Parameters ................................................................. 19 French Pharmacode Parameters............................................................. 20 Industrial 25 Parameters ......................................................................... 20 Interleave 25 Parameters ......................................................................... 21 Matrix 25 Parameters .............................................................................. 23 Codabar Parameters ................................................................................ 24 Plessey Parameters ................................................................................... 25 MSI Parameters........................................................................................ 26 EAN128 Parameters ................................................................................. 27 EAN8 Parameters ..................................................................................... 28 UPCA Parameters .................................................................................... 28 UPCE Parameters..................................................................................... 29 EAN13 Parameters ................................................................................... 30 Activate Editing Formats......................................................................... 31 Editing Format Parameters ..................................................................... 32 Decimal Digits ........................................................................................... 44 Hexadecimal Digits ................................................................................... 45 Key Type.................................................................................................... 46 Key Status.................................................................................................. 46 KBD Wedge Character Table ................................................................. 47 RS-232 Character Table .......................................................................... 47

Page 2

Restore Default Settings

Buzzer Settings < Buzzer Enable>

Exit Setup without Changes

Buzzer Disable

• Buzzer Frequency

Configure Through RS232

8 kHz < 4 kHz > 2 kHz

List Setting

1 kHz

Reading Redundancy Setting

Page1 Page 6

< No Redundancy > Page 2 2 Times Page 7 3 Times Page 3 4 Times Page 8 Page 4 Page 9 Page 5 Page 10

Update

1

2

Enter Setup

Page 3

Scan Mode Setting

Delay between Reread

< Auto Off Mode >

100 ms Continuous Mode

1 sec

Auto Power Off Mode

200ms Alternate Mode

2 sec

Momentary Mode

< 400 ms > Repeat Mode

3 sec

Laser Mode

800 ms Test Mode

5 sec

Keyboard Wedge Parameters

Scanner Time-out Duration

• Activate and Select Keyboard Type * Programming Instructions : (1) Read the label. (2) Program the desired time-out duration by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.

* Programming Instructions : (1) Read the label. (2) Program the desired keyboard number (shown in the following table) by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.

Negative Barcode Setting Enable < Disable >

Update

3

4

Enter Setup

Page 4

• Keyboard Table No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

• Keyboard Alphabets Layout

Keyboard Type PCAT (US) PCAT (French) PCAT (German) PCAT (Italy) PCAT (Swedish) PCAT (Norwegian) PCAT (UK) PCAT (Belgium) PCAT (Spanish) PCAT (Portuguese) PS55 A01-1 PS55 A01-2 PS55 A01-3 PS55 001-1 PS55 001-81 PS55 001-2 PS55 001-82 PS55 001-3 PS55 001-8A PS55 002-1, 003-1 PS55 002-81, 003-81 PS55 002-2, 003-2 PS55 002-82, 003-82 PS55 002-3, 003-3 PS55 002-8A, 003-8A IBM 3477 (Japanese) PS2-30 IBM 34XX/319X, Memorex Telex 122 Keys

< Default Layout > AZERTY QWERTZ

• Keyboard Digits Layout

< Default Layout > Lower Row Upper Row

• Keyboard Capital Lock Type

< Default > Shift Lock Capital Lock

• Capital Lock Setting

Capital Lock ON < Capital Lock OFF > Auto Detection

Update

5

6

Enter Setup

Page 5

• Alphabet Transmission

RS-232 Parameters • Activate RS232 Interface

< Case Sensitive > Ignore Case

• Baud Rate

• Digits Transmission

38400 < Alphanumeric Key > 19200 Numeric Key < 9600 >

• Alt Composing

4800 2400

Yes

1200

< No >

• Inter-Character Delay

300 110 *

• Parity

Programming Instructions : (1) Read the label. (2) Program the desired intercharacter delay by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.

Even Odd < No Parity >

• Data Bit

<8> 7

Update

7

8

Enter Setup

Page 6

• Flow Control (single port only)

Prefix / Postfix Settings

< None >

Prefix Code * Scanner Ready

Postfix Code *

Character Substitution

Data Ready INV. Data Ready

Set 1 *

• Inter-Character Delay

Set 2 * * Set 3 *

Programming Instructions : (1) Read the label. (2) Program the desired intercharacter delay by reading Decimal Digits on page 44. (3) Read the “Validate” label (also on page 44) to complete this setting.

Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 45. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 45) to complete this setting.

Code ID Selection • Clear All Code ID Settings

• Select Code ID Set

Set 1 Set 2 Set 3 Set 4 Set 5

Update

9

10

Enter Setup

Page 7

Code ID Setting

Length Code Setting (2 digits) • Code 39 Length Code

Code 39 * Enable

Italy Pharmacode *

< Disable >

French Pharmacode *

• Italy Pharmacode Length Code

Industrial 25 * Interleave 25 *

Enable

Matrix 25 *

< Disable >

Codabar *

• French Pharmacode Length Code

UPCA * UPCE *

Enable EAN8 *

< Disable >

EAN13 *

• Industrial 25 Length Code Code 93 *

Code 128 *

Enable MSI *

< Disable >

• Interleave 25 Length Code

Plessey * PDF417 * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 45. One character consists of 2 hexadecimal digits. If keyboard interface is used, the associate key type/status can also be specified. The associate key type/status (if specified) must be selected before each character being programmed. (3) Read the “Validate” label (also on page 45) to complete this setting.

Update

11

Enable < Disable >

12

Enter Setup

Page 8

• Matrix 25 Length Code

• Code 128 Length Code

Enable

Enable < Disable >

< Disable >

• UPCA Length Code

• EAN128 Length Code

Enable

Enable < Disable >

< Disable >

• UPCE Length Code

• MSI Length Code

Enable

Enable < Disable >

< Disable >

• EAN8 Length Code

• Plessey Length Code

Enable

Enable < Disable >

< Disable >

• EAN13 Length Code

Enable < Disable >

• Code 93 Length Code

Enable < Disable >

Update

13

14

Enter Setup

Page 9

• Matrix 25

Select Readable Codes • Code 39

Enable < Disable >

< Enable >

• Codabar

Disable

• Italy Pharmacode < Enable > Disable

Enable

• Code 93

< Disable >

• French Pharmacode < Enable > Disable

Enable

• Code 128

< Disable >

• Industrial 25 < Enable > Disable

< Enable >

• EAN128

Disable

• Interleave 25 Enable < Disable >

< Enable >

• MSI

Disable

Enable < Disable >

Update

15

16

Enter Setup