Page 9
Bluetooth Serial Port Parameters
Bluetooth HID Parameters
• Activate Bluetooth Serial Port Interface
• Activate and Select Keyboard Type *
• Device Name Broadcasting
Programming Instructions: (1) Read the label. (2) Program the desired keyboard number (shown in the following table) by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page 53) to complete this setting.
< Yes >
• HID Keyboard Table
No
• Authentication
No. 64 65 66 67 68 69 70 71 72 73 74
Yes < No >
• PIN Code * Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting. (4) Max 6 characters for this PIN Code setting.
Keyboard Type PCAT (US) PCAT (French) PCAT (German) PCAT (Italy) PCAT (Swedish) PCAT (Norwegian) PCAT (UK) PCAT (Belgium) PCAT (Spanish) PCAT (Portuguese) PS55 A01-2 (Japanese)
• Reset Connection
• Power Saving Please read this label when switching connection from one PC to another and the reconnection is needed. <Enable>
• Device Name Broadcasting
Disable
< Yes > No
Update
11
12
Enter Setup
Page 10
• Authentication • Keyboard Digits Layout Yes < No >
< Default Layout >
• PIN Code
Lower Row Upper Row
* Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting. (4) Max 6 characters for this PIN Code setting.
• Keyboard Capital Lock Type < Default >
• Power Saving
Shift Lock Capital Lock
<Enable>
• Capital Lock Setting
Disable
• Keyboard Alphabets Layout Capital Lock ON < Capital Lock OFF > < Default Layout >
Auto Detection
• Alphabet Transmission
AZERTY QWERTZ
< Case Sensitive > Ignore Case
Update
13
14
Enter Setup
Page 11
• Digits Transmission
• Select Code ID Set
< Alphanumeric Key >
Set 1 Numeric Key
Set 2
• Alt Composing
Set 3 Set 4
Yes
Set 5 <No>
Code ID Setting
Prefix / Postfix Settings
Code 39 *
Prefix Code *
Italy Pharmacode *
Postfix Code *
Character Substitution
French Pharmacode * Industrial 25 *
Set 1 *
Interleave 25 * Set 2 *
Matrix 25 *
Set 3 *
Codabar *
Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting.
UPCA * UPCE * EAN8 *
Code ID Selection
EAN13 *
• Clear All Code ID Settings
Update
Code 93 *
15
16
Enter Setup
Page 12
Length Code Setting (2 digits)
Code 128 * MSI *
• Code 39 Length Code
Telepen *
Enable
Plessey *
Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting.
< Disable >
• Italy Pharmacode Length Code Enable < Disable >
• French Pharmacode Length Code Enable < Disable >
• Industrial 25 Length Code Enable < Disable >
• Interleave 25 Length Code Enable < Disable >
Update
17
18
Enter Setup
Page 13
• Matrix 25 Length Code
• Code 93 Length Code
Enable
Enable < Disable >
< Disable >
• Code 128 Length Code
• Codabar Length Code
Enable
Enable
< Disable >
< Disable >
• UPCA Length Code
• EAN128/RSS Length Code
Enable
Enable < Disable >
< Disable >
• UPCE Length Code
• MSI Length Code
Enable
Enable < Disable >
< Disable >
• EAN8 Length Code
• Plessey Length Code
Enable Enable < Disable >
• EAN13 Length Code
< Disable >
• Telepen Length Code Enable Enable
< Disable >
< Disable >
Update
19
20
Enter Setup
Page 14
• Matrix 25
Select Readable Codes • Code 39
Enable < Disable >
< Enable >
• Codabar
Disable
• Italy Pharmacode < Enable > Disable
Enable
• Code 93
< Disable >
• French Pharmacode < Enable > Disable
Enable
• Code 128 < Disable >
• Industrial 25 < Enable > Disable < Enable >
• EAN128 Disable
• Interleave 25
Enable < Disable >
< Enable >
• MSI Disable Enable < Disable >
Update
21
22
Enter Setup
Page 15
• Plessey
• UPCE Enable
< Enable No Addon > < Disable >
Disable No Addon
• Telepen
Enable Addon2 < Disable Addon2 > Enable Enable Addon5 < Disable >
• UPCA
< Disable Addon5 >
• EAN8 < Enable No Addon > < Enable No Addon >
Disable No Addon
Disable No Addon
Enable Addon2 Enable Addon2
< Disable Addon2 >
< Disable Addon2 >
Enable Addon5 Enable Addon5
< Disable Addon5 >
< Disable Addon5 >
Update
23
24
Enter Setup
Page 16
• EAN13
Code39 Parameters • Standard / Full ASCII Code39
< Enable No Addon > Disable No Addon
< Standard >
Enable Addon2
Full ASCII < Disable Addon2 >
• Start / Stop Transmission
< Disable Addon5 >
Enable
Enable Addon5
• RSS14
< Disable >
• Checksum Verification Enable < Disable >
Enable
• RSS Limited
< Disable >
• Checksum Transmission
Enable < Disable >
< Enable >
• RSS Expanded
Disable Enable
Italy Pharmacode Parameters < Disable >
• Checksum Transmission < Enable > Disable
Update
25
26
Enter Setup