The text of a manual · part 2 of 4

Xi3000 Bluetooth Wireless Scanners Configuration Guide, pages 9 to 16

Pages 9 to 16 of 31

The original document is the PDF (288 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the POS-X Xi3000-BT

Page 9

Bluetooth Serial Port Parameters

Bluetooth HID Parameters

• Activate Bluetooth Serial Port Interface

• Activate and Select Keyboard Type *

• Device Name Broadcasting

Programming Instructions: (1) Read the label. (2) Program the desired keyboard number (shown in the following table) by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page 53) to complete this setting.

< Yes >

• HID Keyboard Table

No

• Authentication

No. 64 65 66 67 68 69 70 71 72 73 74

Yes < No >

• PIN Code * Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting. (4) Max 6 characters for this PIN Code setting.

Keyboard Type PCAT (US) PCAT (French) PCAT (German) PCAT (Italy) PCAT (Swedish) PCAT (Norwegian) PCAT (UK) PCAT (Belgium) PCAT (Spanish) PCAT (Portuguese) PS55 A01-2 (Japanese)

• Reset Connection

• Power Saving Please read this label when switching connection from one PC to another and the reconnection is needed. <Enable>

• Device Name Broadcasting

Disable

< Yes > No

Update

11

12

Enter Setup

Page 10

• Authentication • Keyboard Digits Layout Yes < No >

< Default Layout >

• PIN Code

Lower Row Upper Row

* Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting. (4) Max 6 characters for this PIN Code setting.

• Keyboard Capital Lock Type < Default >

• Power Saving

Shift Lock Capital Lock

<Enable>

• Capital Lock Setting

Disable

• Keyboard Alphabets Layout Capital Lock ON < Capital Lock OFF > < Default Layout >

Auto Detection

• Alphabet Transmission

AZERTY QWERTZ

< Case Sensitive > Ignore Case

Update

13

14

Enter Setup

Page 11

• Digits Transmission

• Select Code ID Set

< Alphanumeric Key >

Set 1 Numeric Key

Set 2

• Alt Composing

Set 3 Set 4

Yes

Set 5 <No>

Code ID Setting

Prefix / Postfix Settings

Code 39 *

Prefix Code *

Italy Pharmacode *

Postfix Code *

Character Substitution

French Pharmacode * Industrial 25 *

Set 1 *

Interleave 25 * Set 2 *

Matrix 25 *

Set 3 *

Codabar *

Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting.

UPCA * UPCE * EAN8 *

Code ID Selection

EAN13 *

• Clear All Code ID Settings

Update

Code 93 *

15

16

Enter Setup

Page 12

Length Code Setting (2 digits)

Code 128 * MSI *

• Code 39 Length Code

Telepen *

Enable

Plessey *

Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting.

< Disable >

• Italy Pharmacode Length Code Enable < Disable >

• French Pharmacode Length Code Enable < Disable >

• Industrial 25 Length Code Enable < Disable >

• Interleave 25 Length Code Enable < Disable >

Update

17

18

Enter Setup

Page 13

• Matrix 25 Length Code

• Code 93 Length Code

Enable

Enable < Disable >

< Disable >

• Code 128 Length Code

• Codabar Length Code

Enable

Enable

< Disable >

< Disable >

• UPCA Length Code

• EAN128/RSS Length Code

Enable

Enable < Disable >

< Disable >

• UPCE Length Code

• MSI Length Code

Enable

Enable < Disable >

< Disable >

• EAN8 Length Code

• Plessey Length Code

Enable Enable < Disable >

• EAN13 Length Code

< Disable >

• Telepen Length Code Enable Enable

< Disable >

< Disable >

Update

19

20

Enter Setup

Page 14

• Matrix 25

Select Readable Codes • Code 39

Enable < Disable >

< Enable >

• Codabar

Disable

• Italy Pharmacode < Enable > Disable

Enable

• Code 93

< Disable >

• French Pharmacode < Enable > Disable

Enable

• Code 128 < Disable >

• Industrial 25 < Enable > Disable < Enable >

• EAN128 Disable

• Interleave 25

Enable < Disable >

< Enable >

• MSI Disable Enable < Disable >

Update

21

22

Enter Setup

Page 15

• Plessey

• UPCE Enable

< Enable No Addon > < Disable >

Disable No Addon

• Telepen

Enable Addon2 < Disable Addon2 > Enable Enable Addon5 < Disable >

• UPCA

< Disable Addon5 >

• EAN8 < Enable No Addon > < Enable No Addon >

Disable No Addon

Disable No Addon

Enable Addon2 Enable Addon2

< Disable Addon2 >

< Disable Addon2 >

Enable Addon5 Enable Addon5

< Disable Addon5 >

< Disable Addon5 >

Update

23

24

Enter Setup

Page 16

• EAN13

Code39 Parameters • Standard / Full ASCII Code39

< Enable No Addon > Disable No Addon

< Standard >

Enable Addon2

Full ASCII < Disable Addon2 >

• Start / Stop Transmission

< Disable Addon5 >

Enable

Enable Addon5

• RSS14

< Disable >

• Checksum Verification Enable < Disable >

Enable

• RSS Limited

< Disable >

• Checksum Transmission

Enable < Disable >

< Enable >

• RSS Expanded

Disable Enable

Italy Pharmacode Parameters < Disable >

• Checksum Transmission < Enable > Disable

Update

25

26

Enter Setup