Page 1
Table of Contents Xi3000 Bluetooth Wireless Scanners
Configuration Guide
Revision History .........................................................................................v Restore Default Settings ............................................................................1 Exit Setup without Changes......................................................................1 Set Connection............................................................................................1 RF Auto Shutdown Duration....................................................................1 Transmit Buffer Setting ............................................................................1 Memory Mode Parameters .......................................................................2 List Setting..................................................................................................3 Buzzer Settings ...........................................................................................3 Reading Redundancy Setting....................................................................4 Scan Mode Setting .....................................................................................4 Auto-Sense Setting .....................................................................................4 Scanner Time-out Duration ......................................................................5 Negative Barcode Setting ..........................................................................5 Delay between Reread ...............................................................................5 Keyboard Wedge Parameters ...................................................................6 RS-232 Parameters ....................................................................................9 Bluetooth Serial Port Parameters...........................................................11 Bluetooth HID Parameters......................................................................12 Prefix / Postfix Settings............................................................................15 Character Substitution ............................................................................15 Code ID Selection.....................................................................................15 Code ID Setting ........................................................................................16 Length Code Setting (2 digits) ................................................................18 Select Readable Codes .............................................................................21 Code39 Parameters..................................................................................26 Italy Pharmacode Parameters ................................................................26 French Pharmacode Parameters ............................................................27 Industrial 25 Parameters.........................................................................27 Interleave 25 Parameters ........................................................................28 Matrix 25 Parameters..............................................................................30 Codabar Parameters................................................................................31 Plessey Parameters...................................................................................32 Telepen Parameters .................................................................................32 MSI Parameters .......................................................................................33 EAN128 Parameters ................................................................................34 EAN8 Parameters ....................................................................................35
Page 2
UPCA Parameters....................................................................................35 UPCE Parameters....................................................................................36 EAN13 Parameters ..................................................................................37 RSS Code ID Selection ............................................................................38 RSS14 Parameters ...................................................................................38 RSS Limited Parameters.........................................................................39 RSS Expanded Parameters .....................................................................39 Activate Editing Formats ........................................................................40 Editing Format Parameters ....................................................................41 Decimal Digits ..........................................................................................53 Hexadecimal Digits ..................................................................................54 Key Type...................................................................................................55 Key Status.................................................................................................55 KBD Wedge Character Table.................................................................56 RS-232 Character Table..........................................................................56
Page 3
Revision History Version V 1.00 V 2.00
Release Date Oct. 31, 2005 Dec.30, 2005
Notes First release. Supports Bluetooth HID. Firmware version: V4.10 1. Updated: z Bluetooth HID: The default setting of Capital Lock Setting is changed from Auto Detection to Capital Lock OFF. z Bluetooth HID doesn’t support the following functions on PDA for Win CE. „ Capital Lock Setting: Auto Detection „ Digit Transmission: Numeric Key „ Alt Composing 2. Firmware version: V4.20 Typo: 1. Baud Rate 19200 instead of 119200 at page 9. 2. by reading Decimal Digits at page 52 instead of page 53. 3. by reading Hex Decimal Digits at page 53 instead of page 53.
V2.10
Jan.18, 2006
V2.11
Jan.27, 2006
V2.12 V2.13 ~ V2.14 V2.15
Mar.03, 2006 Nov, 06 2006
HID Japanese keyboard added. Same as V2.12
Nov, 13 2006
Power Saving added for SPP and HID at page 11 and 13
Page 4
Restore Default Settings
Memory Mode Parameters • Memory Mode
Exit Setup without Changes
Enable < Disable >
•
Set Connection *
Clear Data Clear
Programming Instructions: (1) Read the label. (2) Read the Serial Number barcode on the bottom of the desired Xi3000 Base Station within 5 seconds to complete this setting.
Confirm
• Send Data
RF Auto Shutdown Duration
• Memory Data Delay * <0>
Programming Instructions: (1) Read the label. (2) Program the desired auto shutdown duration (in minutes) by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page 52) to complete this setting.
2 sec 250 ms
Transmit Buffer Setting
3 sec 500 ms
Enable
5 sec 1 sec
< Disable >
8 sec
Update
1
2
Enter Setup
Page 5
List Setting
Reading Redundancy Setting < No Redundancy >
Page1
2 Times
Page 6 3 Times
Page 2
4 Times
Page 7
Scan Mode Setting
Page 3 Page 8
< Auto Off Mode >
Page 4
Continuous Mode Page 9
Auto Power Off Mode
Page 5
Alternate Mode Page 10
Momentary Mode
Buzzer Settings
Repeat Mode Laser Mode
< Buzzer Enable>
Test Mode
Auto-Sense Setting
Buzzer Disable
• Buzzer Frequency Enable 8 kHz
<Disable> < 4 kHz >
2 kHz 1 kHz
Update
3
4
Enter Setup
Page 6
Keyboard Wedge Parameters
Scanner Time-out Duration
• Activate and Select Keyboard Type
* Programming Instructions: (1) Read the label. (2) Program the desired time-out duration by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page 53) to complete this setting.
* Programming Instructions: (1) Read the label. (2) Program the desired keyboard number (shown in the following table) by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page 52) to complete this setting.
Negative Barcode Setting
• Keyboard Table No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
Enable < Disable >
Delay between Reread 100 ms 1 sec 200ms 2 sec < 400 ms > 3 sec 800 ms 5 sec
Update
5
6
Keyboard Type PCAT (US) PCAT (French) PCAT (German) PCAT (Italy) PCAT (Swedish) PCAT (Norwegian) PCAT (UK) PCAT (Belgium) PCAT (Spanish) PCAT (Portuguese) PS55 A01-1 PS55 A01-2 PS55 A01-3 PS55 001-1 PS55 001-81 PS55 001-2 PS55 001-82 PS55 001-3 PS55 001-8A PS55 002-1, 003-1 PS55 002-81, 003-81 PS55 002-2, 003-2 PS55 002-82, 003-82 PS55 002-3, 003-3 PS55 002-8A, 003-8A IBM 3477 (Japanese) PS2-30 IBM 34XX/319X, Memorex Telex 122 Keys
Enter Setup
Page 7
• Keyboard Alphabets Layout
• Alphabet Transmission
< Default Layout >
< Case Sensitive > Ignore Case
AZERTY
• Digits Transmission
QWERTZ
• Keyboard Digits Layout < Alphanumeric Key > Numeric Key
< Default Layout >
• Alt Composing
Lower Row Upper Row
Yes
• Keyboard Capital Lock Type
< No >
• Inter-Character Delay < Default > *
Shift Lock
Programming Instructions: (1) Read the label. (2) Program the desired intercharacter delay by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page 52) to complete this setting.
Capital Lock
• Capital Lock Setting
• Laptop Support
Capital Lock ON
<Disable> < Capital Lock OFF >
Enable
Auto Detection
Update
7
8
Enter Setup
Page 8
• Flow Control (single port only)
RS-232 Parameters • Activate RS232 Interface
< None > Scanner Ready
• Baud Rate
Data Ready INV. Data Ready
115200
• Inter-Character Delay
38400
*
19200
Programming Instructions: (1) Read the label. (2) Program the desired intercharacter delay by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page 52) to complete this setting.
< 9600 > 4800 2400 1200
Parity Even Odd < No Parity >
• Data Bit <8> 7
Update
9
10