The text of a manual · part 4 of 17
Xplorer GLX Users' Guide, pages 25 to 34
Pages 25 to 34 of 152
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Pasco PS-2002
Page 25
X p l o r e r
G L X
U s e r s ’
G u i d e
19
Negative DX and DY
Positive DX and DY
When the cursors swap places, the signs of ∆X and ∆Y change
Slope Tool Select the Slope Tool from the Tools menu to measure the slope of a tangent line at one point on the data plot. A pair of crosshairs marks the point at which the slope is measured. Labels on the Graph’s edges show the coordinates of the point, and the slope is displayed at the bottom of the screen.
Slope Tool
Use the left and right arrow keys to move the Slope Tool to adjacent points. Use the up and down arrow keys to send it to the first and last points. Press and hold the left or right arrow key to move the Slope Tool quickly. If you have a mouse, you can move the Slope Tool by dragging the circle at the intersection of the cross hairs left and right.
Y X
Slope Slope Tool
Statistics Select Statistics from the Tools menu to put the Graph into Statistics mode. The Graph displays the minimum, maximum, average, and standard deviation (σ) of the data inside the region of interest (ROI), which is indicated by a dashed box. Region of interest
Active Cursor Stationary Cursor
Statistics Statistics mode
Two cursors designate the left and right sides of the ROI. The larger cursor is the active one and can be moved with the arrow keys or mouse.4 As the active cursor moves, one side of the box moves with it. The smaller cursor indicates the side of the ROI that does not move.
4See page 16 for detailed instructions on moving the cursor with the keypad or mouse.
Region of interest
To switch the active cursor to the other side of the box, hold Esc and press Õ . Linear Fit When Linear Fit is selected from the Tools menu, a best-fit line is applied to the data in the ROI. (See “Statistics” above for instructions on setting the ROI.) The slope, the Y-intercept, the mean squared error (MSE), and the root mean squared error ( MSE) of the linear fit are displayed at the bottom of the screen along with the correlation coefficient (r) of the data in the ROI.
Linear Fit
Page 26
20
G r a p h
When the Linear Fit is turned on, the special option Create Calculation from Linear Fit appears in the Tools menu (see page 22). Linear Fit can be useful even when the graphed data are not linear (quadratic or exponential, for instance). See “Graph Linearization” on page 47.
Area Tool Select the Area Tool from the Tools menu to measure the area between the data plot and the X-axis in the ROI. (See “Statistics” above for instructions on setting the ROI.) For data plotted below the X-axis, the area is measured as negative. The value of area displayed at the bottom of the screen is the total area above the X-axis minus the total area below the X-axis.
Positive Area
Negative Area
Total Area is area above the axis minus area below the axis.
Area Tool
Derivative This tool overlays a graphical representation of the derivative (or rate of change) of the data. In some cases, the Graph may need to be rescaled in order to see the overlaid derivative. The Derivative Tool is designed for titration experiments in which it is necessary to identify a point in a data set at which the maximum rate of change occurs. Trigger The Trigger is a tool that allows you to control how the GLX collects data. With the Trigger, you make the GLX delay data recording (after you press ) until a certain condition is met by the incoming data. The Trigger has two parameters: Trigger Edge, which can be rising or falling, and Trigger Level, which specifies the data value that must be crossed. For example, on a voltage versus time graph, if you set the Trigger Edge to rising and the Trigger Level to 5 volts, data recording will not start until the measured voltage rises above 5 volts. The Trigger can be used in normal graph mode to start continuous recording, or it can be used in Scope Mode (see page 22) to repeatedly trigger bursts of data collection. In both modes, the Graph must have time on the horizontal axis. To turn on the Trigger, select it from the Tools menu.5 A horizontal dashed line appears on the Graph indicating the Trigger Level. Press the up and down arrow keys to change the Trigger Level. Press the right arrow key to cycle through rising edge, falling edge, and disabled. (The Trigger is initially disabled, so you must press the right arrow key at least once to enable it.) Increase Trigger Level Open Trigger Settings
Enable, Disable, and Change Trigger Edge Decrease Trigger Level
Arrow Indicating Trigger Edge
Trigger Level
Trigger
5The Trigger turns on automatically when you turn on Scope mode. See page 22.
Page 27
X p l o r e r
G L X
The Trigger affects data recording even if you are not viewing the Graph. If you have set up two or more triggers on separate Graph pages,6 data recording will start when the most recently set trigger condition is met. Trigger Settings When the Trigger is turned on, you can open the Trigger Settings dialog box by pressing the left arrow key (you can also select it from the Tools menu). In the dialog box, use the arrow keys to highlight Trigger Enabled and press to enable or disable the Trigger. To change the edge from rising to falling, or vice-versa, use the arrow keys to highlight Trigger Edge and press . To set the level, use the arrow keys to highlight Trigger Level, press , enter the desired value on the keypad, and press again.
U s e r s ’
G u i d e
21
6For information about multiple Graph pages, see “New Graph Page” on page 24.
F1
F2
Trigger Settings dialog box
You can also turn on the Stop Condition, which causes data collection to automatically stop at a specified time. To turn on the Stop Condition in the Trigger Settings dialog box, use the arrow keys to highlight Stop Condition and press . When the Stop Condition is on, an icon ( ) and vertical dashed line appear on the Graph indicating the stop time. While viewing the Graph, hold down Esc and press the left and right arrow keys to adjust the stop time. For the Stop Condition to work, the Trigger must be turned on (but does need to be enabled).
Stop time
When you have finished changing the settings in the Trigger Settings dialog box, press F1 to accept the changes, or press F2 to cancel them. Stop condition
Zoom Use the Zoom Tool to enlarge an area that you define by drawing a rectangle. Select Zoom from the Tools menu; a zoom cursor ( ) appears. Move the cursor (using the arrow keys) to where you want one corner of the rectangle. Press . Move the cursor to define the diagonally opposite corner of the rectangle. Press again. The area enclosed by the rectangle enlarges to fill the screen. If you have a mouse, you do not have to open the Tools menu to zoom. Just hold down Esc while you click and drag on the Graph to draw the rectangle.7 Position the cursor to define one corner. Press .
Move the cursor to define the opposite corner. Press .
7See also page 17 for other ways to scale the Graph with a mouse.
Area enlarges.
Zoom Tool
Swap Cursors This option appears in the Tools menu when you are using the Delta Tool, Statistics, Linear Fit, or Area Tool. When you select Swap Cursors, the active and inactive cursors swap places, allowing you to move the previously stationary corner of the Delta Tool or side of the ROI. To swap cursors without opening the menu: hold Esc , press Õ , and release both keys. Toggle Active Data This option appears in the Tools menu when the Graph is in one of the two-data set modes (see pages 23–24). Select it to switch focus from one data set to the other. The active data set is the one to which the Data Cursor
Esc
+ Õ
Swap Cursors Shortcut
Page 28
22
G r a p h and other tools are applied. In cases where the two data sets are scaled separately, the active that is scaled. To toggle data without opening the menu: hold Esc , press keys.
, and release both
Esc
+
Toggle Data Shortcut
Create Calculation from Linear Fit This option appears in the Tools menu when the Linear Fit (see page 19) is turned on. Select this option to automatically create an equation in the calculator based on the slope and y-intercept of the currently display best-fit line. If the equation of the best fit line is y = mx + b , where m is the slope and b is the y-intercept, then the calculation will take the form x = ( 1 ⁄ m )y – b ⁄ m . This calculation will appear in the Calculator and in data source menus with the name “Linear Fit Cal.” For instructions on working with calculations, see page 41.
F4 Graphs Menu The Graphs menu contains options8 to control the appearance of the Graph, make it emulate an oscilloscope, make it plot two data sets simultaneously, manage multiple pages, and print.
The Graphs menu
8To select an option from the Graphs menu
Keypad 1. Press F4 to open the Graphs menu. 2. Use the arrow keys to move the highlight to the desired menu option and press ; or press the number on the keypad corresponding to the desired menu option. Mouse 1. Click “Graphs” at the bottom of the screen to open the Graphs menu. 2. Click the desired menu option.
Data Cursor Select this option to turn on or off the Data Cursor and Coordinates displayed on the Graph. See page 16 for more information. Connected Lines Select this option from the Graphs menu to turn on or off the lines connecting the data points.
Graph with connected lines (left) and without connected lines (right)
Scope Mode Select Scope mode from the Graphs menu to make the GLX emulate a digital storage oscilloscope. In this mode, the GLX collects and displays data in repeated bursts. The length of the burst and the sample rate are determined by the time scale of the Graph display. Scope mode can be used with any sensor to collect bursts of data; it is especially useful with the GLX’s built-in sound sensor (see page 58) or voltage sensor. Scope mode
When you turn on Scope mode, the Graph automatically sets its time range to 30 milliseconds and turns on the Trigger.9 It also adjusts the sampling rate of the displayed sensor so that it will collect about 500 data points (or as many as possible) in each burst. If you change the Graph’s time scale,10 the GLX automatically adjusts the sampling rate.
9The Trigger is initially disabled. See page 20 for instructions on enabling and setting the Trigger. 10See “F1 Autoscale” and “F2 Scale/
Move” on page 16.
Page 29
X p l o r e r
G L X
U s e r s ’
G u i d e
23
After you press , the GLX begins collecting and displaying a series of data bursts (each burst is enough data fill the Graph from left to right). If you have enabled the Trigger, the GLX waits for the trigger condition to be met before collecting each burst. While Scope-mode data collection is in progress, you can change the scale of the Graph (with F1 Autoscale, F2 Scale/Move, or the mouse) and you can change the Trigger settings with the arrow keys. To stop data collection, press again. The GLX will save the last-collected data burst as Run #1 (or #2, #3, #4, etc.). You can also use the Trigger’s Stop Condition (see page 21) to make the GLX stop automatically after collecting a single data burst. You can use Scope Mode in conjunction with Two Measurements mode or Two Graphs mode (see below) to display two traces simultaneously.
Two Measurements Select this option from the Graphs menu to put the Graph into Two Measurements mode. In this mode, two measurements (or data sets) are graphed simultaneously. Run Number of First Measurement (select to change)
Run Number of Second Measurement (select to change)
Data Source of Second Measurement (select to change)
Data Source of First Measurement (select to change)
Active Data (black) Inactive Data (gray) Two Measurements mode
The data source and scale of the First Measurement are displayed on the left side, and the data source and scale of the Second Measurement is displayed on the right side. Select either the left or right data source field11 to change the corresponding measurement. The run number of the First Measurement is displayed in the upper left corner of the Graph, and the run number of the Second Measurement is displayed in the upper right corner. To change the run number of either measurement, select the corresponding run number field.11 One of the measurements is plotted in black, and the other one in gray. The measurement in black is the active data. To switch activity to the other measurement, hold Esc and press . The Data Cursor appears on the active data. If you select a tool from the Tools menu, it is applied to the active data set. If you press F2 to scale or move vertically, only the active data will change.12 However, moving the Graph horizontally or changing the horizontal scale will affect both sets. If you are using a mouse, you can switch activity to a measurement by clicking on the line above its run number. Vertically scale each measurement by dragging its numeric labels (on the left or right side of the Graph).
11To select a data source field or run number field:
Keypad 1. Press to light up the active fields. 2. Use the arrow keys to move the highlight to the desired field. 3. Press again to open the menu. 4. Use the arrow keys to move the highlight to the desired menu option and press ; or press the number on the keypad corresponding to the desired menu option. Mouse 1. Click the desired field to open the menu. 2. Click the desired menu option.
12The exception to this rule is when both data sets are of the same units (both temperature in °C, for instance); in that case, both data sets scale together.
Page 30
24
G r a p h
Typically you would use Two Measurements mode to display data from two different sources, but you can also use it to display two runs from the same source. Select the same source from both data source fields, and different runs from each run number field. For another way to display two runs from the same source, see “Two Runs” below.
Two Runs Select Two Runs from the Graphs menu to display two data sets from a single data source. In this mode, a second run appears on the Graph. A second run number field appears in the upper right corner (below the first run number), which you can select to choose a different run. One of the runs is plotted in black, and the other one in gray. The run in black is the active data. To switch activity to the other run, hold Esc and press . The Data Cursor appears on the active data. If you select a tool from the Tools menu, it is applied to the active data set.
Two Runs mode
Both runs share a single pair of axes and they are scaled and moved together. If you are using a mouse, you can switch activity to a run by clicking on the line above its run number. Two Graphs Select Two Graphs from the Graphs menu to display two separate graphs simultaneously. This mode is similar to Two Measurements mode (see page 23), but each measurement is plotted on the top or bottom half of the screen, rather than overlapping. One of the measurements is plotted in black, and the other one in gray. The measurement in black is the active data. To switch activity to the other measurement, hold Esc and press . The Data Cursor appears on the active data. If you select a tool from the Tools menu, it is applied to the active data. If you press F2 to scale or move vertically, only the active data will change. However, moving the Graph horizontally or changing the horizontal scale will affect both sets.
Two Graphs mode
If you are using a mouse, you can switch activity to a measurement by clicking on it. New Graph Page The GLX supports an unlimited number of graph pages. Select New Graph Page from the Graphs menu to configure a new graph while preserving the previous one. When two or more graph pages exist, each page appears in the Graphs menu. To make a page visible, select it from the menu. If added graph pages make the Graphs menu too long to fit on the screen, an , ) will appear on the right side of the menu to indiarrow or arrows ( cate that some of the menu options are not visible. Press the up or down arrow key multiple times to move the highlight beyond the visible portion of the menu. The menu will scroll to bring other options into view. If you are using a mouse, you can click the arrows to scroll the menu.
The Graphs menu as it appears when multiple pages exist
Page 31
X p l o r e r
G L X
U s e r s ’
G u i d e
25
Print If there is a printer connected to the GLX, select Print from the Graphs menu to print the currently displayed graph page. Print All Select Print All to print all of the graph pages. For more information, see “Printing” on page 91.
Delete Graph Page This option is available when two or more graph pages exist. When you select Delete Graph Page from the Graphs menu, the currently displayed page is deleted and the next page appears. (If there is no next page, the previous page appears.)
Data Annotation The GLX’s data-annotation capability allows you to attach notes to data points in the Graph display. You can add these notes while you are viewing the Graph either during or after data collection.13 A note (represented by a flag icon: ) can include a text message, an audio recording of your voice, or both; it can also be “empty” (not containing text or audio).
13In order to add a note during data col- lection, the GLX must be in Continuous Sampling mode (its default mode), rather than Manual Sampling mode. See page 57 for more information.
Data with notes
There are two ways to attach a note to a data point in the Graph display: •
Press quickly to mark a data point with an icon ( ) representing an empty note. You can later add text and audio to this note.
•
Press and hold and begin speaking to mark a point and immediately record an audio message. When you are finished speaking, release .14
In both cases, the note is added at the location of the Data Cursor.15 See page 16 for instructions on moving the Data Cursor. If you are adding notes during data collection, it is often convenient to have the cursor tracking the data so that notes are always attached to the most recently collected point; press the down arrow key to make the cursor track the data.
After you have added a note, you can access its audio and text by positioning the Data Cursor on it.
14
The GLX cannot record audio for a data note when the microphone is configured as a sound sensor or sound level sensor. See page 58 for more information. 15The Data cursor must be turned on
(see page 22) in order to use data annotation.
Page 32
26
G r a p h
A note with the Data Cursor positioned on it
To make the Data Cursor jump directly to a note, hold Esc and press one of the arrow keys. Press Esc plus the left or right arrow key to make the cursor jump to the next visible note in either direction; press Esc plus the up or down arrow key to make the cursor jump to the first or last visible note. When the cursor lands on a note, the audio portion (if any) starts playing16 and the text portion of the note (if any) appears.
Annotation Menu To change any of a note’s attributes, position the Data Cursor on the note and press ; the Annotation menu will open.
16If you have not changed the default setting, the audio plays through the GLX’s built-in speaker; otherwise it plays through the output device specified in the Audio Settings dialog box, which is accessed from the Settings screen. See page 87 for more information.
If you have a mouse, you can open the menu by clicking the flag icon.
Annotation Menu
Select17 any of the following menu options.
17To select and option from the
Annotation menu
Edit Note Select this option to open the Note Editor dialog box. There you can read the text, listen to the audio, enter new text, change existing text, and record new audio. See “Note Editor Dialog Box” below for instructions. Always Show Text This option is either turned on (with a check mark appearing next to it in the menu) or off (no check mark). When the option is on, the note’s text is visible on the Graph even when the cursor is not on the note. To switch Always Show Text on or off, select it from the Annotation Menu. Delete Note Select this option to delete the entire note, including the text and audio portions and the flag icon. Move Select this option to move the note to a different data point. After you have selected Move, the flag icon becomes mobile; use the arrow keys (or mouse) to move the icon to a different data point and press to attach it to that point. Hide All Text and Show All Text Select either of these options to hide or show the text of all notes in the displayed data run. These options are equivalent to turning on or off the Always Show Text option for every note. Delete All Notes Select this option to delete every note in the displayed data run.
Keypad 1. Position the Data Cursor on the data note. 2. Press to open the menu. 3. Use the arrow keys to move the highlight to the desired menu option and press ; or press the number on the keypad corresponding to the desired menu option. Mouse 1. Click the flag icon (
) to open the menu. 2. Click the desired menu option.
Page 33
X p l o r e r
G L X
U s e r s ’
G u i d e
27
Note Editor Dialog Box
Text Portion Audio Portion Audio Duration
Audio Size F1
F2
F3
F4
Note Editor Dialog Box
The Note Editor opens when you select Edit Note from the Annotation menu. The text portion of the note appears in the upper half of the box. Use the GLX’s keypad (or an attached USB keyboard) to enter new text or edit existing text.18 Press F4 to open the Text menu, which contains options related to entering and editing text.
18
See “Multipress Text Input Mode” on page 90.
F4
Text Menu
To type a capital letter, select Shift or Caps Lock.19 To take the keypad out of multipress text mode (to type only numerals), select Num Lock. To delete the entire text portion of the note, select Delete Text. The audio portion of the note is graphically represented in the lower half of the Note Editor along with the audio recording duration and size. Press F3 to open the Audio Note menu, which contains options for recording and playing audio.14
19To select an option from the Text or
Audio Note menu
Keypad 1. Press
F3 or
F4 to open the menu. 2. Use the arrow keys to move the highlight to the desired menu option and press ; or press the number on the keypad corresponding to the desired menu option. Mouse 1. Click “Audio Note” or “Text” at the bottom of the screen. 2. Click the desired menu option. F3
Audio Note Menu
To record new audio, select Record Audio Note and begin speaking; press F3 to stop recording.14 When you record new audio, the note’s previous audio is overwritten. To play the audio portion of the note, select Play Audio Note from the Audio Note menu.16 To delete the audio, select Delete Audio Note. Two other menu options, Record Quality and Record Level, allow you to set the GLX’s audio sample rate, bits per sample, and microphone volume before you record audio. The properties set using these options are identical to those in the Audio Settings dialog box (which is accessed from the Settings screen); see page 87 for details. When you have finished changing the text and audio portions of the note, press F1 to accept changes and close the Note Editor, or press F2 to cancel changes.
Page 34
28
T a b l e
Table Use the Table to display data, edit or enter data manually, and display statistics on data sets. The Table can show up to four columns of numeric or text data.
To Open the Table From the Home Screen, do one of the following: press
F2
, the function key below the Table icon;
use the arrow keys to highlight the Table icon, then press
; or The Table icon on the Home Screen click the Table icon. From anywhere in the GLX environment, you can always get to the Table with the shortcut + F2 . Data Source Run Number
Data source field with nothing selected
The Table Display
Choosing Data to Display The Table can contain up to four columns.20 Each column can be set to display data from one data source. If time is displayed, it occupies its own column. A column can also be empty (not set up for any data source).
20See “F4 Tables” on page 31 for instructions on changing the number of displayed columns.
The active fields described below are used to control what data appear in each column. (See page 14 for more information about active fields.) Data Source Select the data source field21 at the top of a column to choose a sensor measurement, calculation, manually entered data set, or time, or to clear the column. If no data source is assigned to a column, the data source field appears as a series of dashes (----).
21To select the data source, units, or run number field
Keypad 1. Press to light up the active fields. 2. Use the arrow keys to move the highlight to the desired field. 3. Press again to open the menu. 4. Use the arrow keys to highlight the desired menu option and press ; or press the number on the keypad corresponding to the desired menu option. Mouse 1. Click the desired field to open the menu. 2. Click the desired menu option.
Data Source menu