Page 17
Opticon OPL 9728 Specifications Manual
11. Packaging Specifications 11.1. Individual Packaging Specification Put the data collector in a protective foam bag and place it in an individual packing box, then place the accessories into the box. Close the box and affix a label to the side of the box.
Figure 9: Individual packaging
11.2. Accessory Specification These accessories are enclosed in an individual package: •
1 lithium-ion battery
•
1 hand strap
17
Page 18
Opticon OPL 9728 Specifications Manual
12. Durability 12.1. Shock 12.1.1. Drop Test (without packaging) No malfunction occurred after the following drop test. Drop Test: Drop the data collector from a height of 1.5 m onto a concrete floor. Each side of the data collector impacted the floor three times.
Figure 10: Shock test
12.2. Vibration Strength No malfunction occurred after the following vibration test. Vibration test: Increase the frequency of the vibration from 12 Hz to 100 Hz with accelerated velocity 19.6 m/s2 (2 G) for 6 minutes in non-operating state. Repeat this routine 10 times for 60 minutes in each of X, Y, Z direction once for a total of 180 minutes.
18
Page 19
Opticon OPL 9728 Specifications Manual
12.3. Dust and Drip Proof IEC IP54 Dust Prevention Level 5
Details Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment; complete protection against contact.
Water Prevention Level 4
Details Water splashing against the enclosure from any direction shall have no harmful effect.
13. Reliability MTBF (Mean Time Between Failures) of this product except for the laser diode and the mirror motor scan unit is 8 years. Life cycle of the laser scan engine (including the life cycle of the laser diode and the mirror motor) is 10,000 hours. Keypad operating life: The keypad expected usability is 1,000,000 uses (cycles) when the key is pressed with 1 kgf force. The estimate of MTBF and product life cycle is based on standard operation of the product within the recommended temperature range and without extreme electronic or mechanical shock. The MTTR (Mean Time To Repair) of this product is one hour.
19
Page 20
Opticon OPL 9728 Specifications Manual
14. Regulatory Compliance 14.1. Laser Safety The data collector emits laser beams. JIS C6802: 2005: Laser class 1 IEC 825-1/EN 60825-1: Laser class 1 FDA CDRH Laser class I. Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice No. 50 dated June 24, 2007. Class I laser devices are not considered to be hazardous when used for their intended purpose. Avoid staring into the laser beam.
14.2. EMC EN55022 EN55024 VCCI Class B: This is a Class B product, to be used in a domestic environment based on the Technical Requirement of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Please install and use the equipment according to the instruction manual. FCC Part 15 Subpart B Class B: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
14.3. RoHS RoHS: The restriction of the use of certain hazardous substances in electrical and electronic equipment, 2002/95 EC.
14.4. State of California: Perchlorate Best Management Practices The batteries on some Opticon products may contain Perchlorate. To comply with California Perchlorate Best Practice Regulations and the Law for the Promotion of Utilization of Recyclable Resources (Japan), products that may contain Perchlorate materials should be properly labeled on the exterior of all outer shipping packages and/or in locations that otherwise satisfy the California Perchlorate Best Management Practices.
20
Page 21
Opticon OPL 9728 Specifications Manual
15. Safety Handle this product carefully. Do not deliberately subject it to any of the following.
15.1. Shock Do not throw or drop the data collector. Do not drop or put heavy items on this product or its cable.
15.2. Temperature Conditions Do not use the data collector at temperatures outside the specified range. Do not use near heat sources such as radiators, heat registers, stoves, or other types of devices that produce heat. Do not use in areas exposed to direct sunlight for long periods of time. Do not pinch or forcibly bend the cable, especially at very low temperature.
15.3. Foreign Materials Do not use the data collector near water or other liquids, as well as in extremely high humidity. Do not immerse the data collector in liquids. Do not use in dusty environments. Do not subject the data collector to chemicals. Do not insert foreign substances into the device.
15.4. Other Do not plug/unplug the connectors before disconnecting the power. Do not attempt to disassemble, modify or update this device. Do not use near microwaves, medical devices, or RF-emitting devices. The data collector may not perform properly in environments when placed near a flickering light, such as a computer monitor, television, etc. Do not use in the reach of blinking lights such as CRT. The data collector may be damaged by voltage drops.