OPL 9728 Specifications Manual, pages 9 to 16

Pages 9 to 16 of 22

The original document is the PDF (644 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Opticon OPL-9728

Page 9

Opticon OPL 9728 Specifications Manual

7. Optical Specifications 7.1. Laser Scan Specifications Parameter

Specification

Unit

Light-emitting element

Red laser diode, Emission wavelength

650 ±10 (25° C)

nm

Light output

1.0 or less mW

Scanning method

Bi-directional scanning, Scanning speed

100 ±20 scans/s

Scan angle

Scan angle: 54 ±5

°

Read angle: 44 (Min)

°

Note: Refer to chapter 8, “Technical Specifications,” to read about scanning performance.

7.2. Laser Scan Standards 7.2.1. Laser Scan Tilt Maximum tilt between both ends of laser scan line. Less than 1.2° upward tilt from the scan origin. Maximum of 3.1 mm when measured at a point 150 mm away from the scan origin. (The skew angle of this measurement was 0°.) Measurement was done from the center of the scan line.

9

Page 10

Opticon OPL 9728 Specifications Manual

7.2.2. Scan Curvature Maximum gap between the straight line connecting both ends of laser scan line and the actual laser scan line. Less than 1.27° curvature from the scan origin. Maximum of 3.3 mm curvature when measured at a point 150 mm away from the scan origin. Measurement was done from the center of the scan line.

Figure 2: Scan tilt and curvature

8. Technical Specifications The conditions for technical specifications are as follows, unless otherwise specified in each section. Conditions Ambient temperature and humidity:

Room temperature (5 to 35º C) Room humidity (45% to 85% RH)

Ambient light:

500 to 900 lx

Background:

Barcode = black Space = white Margin = white Background of label = black

8.1. Print Contrast Signal (PCS) 0.45 or higher (over 70% of reflectivity of space and quiet zone). PCS= Scanning performance may decline if dirt or scratches mar the optical window. Keep the optical window clean.

8.2. Minimum Resolution 0.15 mm

10

Page 11

Opticon OPL 9728 Specifications Manual

8.3. Scan Area and Resolution

Reso lu t ion 0 .15 Reso lu t ion 0 .25

Reso lu t ion 0 .5 Reso lu t ion 1 .0

Figure 3: Depth of field

Symbology

Resolution (mm)

Decode Depth (mm)

PCS

Code 39

1.0

60–300

0.9

Code 39

0.5

35–210

0.9

Code 39

0.25

35–120

0.9

Code 39

0.15

35–70

0.9

Barcode Sample: OPTOELECTRONICS Test Sample N/W ratio:

1:2.5

Angle:

α = 0°, β = 15°, γ = 0°

Curvature:

R=∞

11

8 TUV

0 -

7PQRS

.*...

ENT

3DEF 2 ABC

5 JKL

6MNO

CLR BS

1

4GH I

Sh i f t

M in mu i m read ing d is tance

Conditions

9WXYZ

40 35

60 52

44゚

75

145

240

365

8.3.1. Depth of Field The depth of field is measured from the edge of the data collector. The scanning range is within the circular arc centered on the scan origin.

Page 12

Opticon OPL 9728 Specifications Manual

Resolution

Symbology

PCS

Quiet Zone

Digit

1.0 mm

Code 39

0.9

25 mm

1

0.5 mm

Code 39

0.9

18 mm

3

0.25 mm

Code 39

0.9

10 mm

8

0.15 mm

Code 39

0.9

7 mm

10

Note: dirt or scratches on the mask will degrade scanning performance. Always handle the data collector carefully.

8.4. Pitch, Skew, and Tilt 8.4.1. Pitch Angle α = ±25°

Figure 4: Pitch

Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance:

90 mm from the edge of the data collector

Label:

Pitch, Skew Angle PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2.5 Dead Zone, Tilt Angle PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm

Angle:

Curvature: R = ∞, Skew Angle = β +15° (for measuring Pitch Angle and Tilt Angle)

12

Page 13

Opticon OPL 9728 Specifications Manual

β=5 0゚

8゚

8゚

0゚ β=5

8.4.2. Skew Angle and Dead Zone Skew angle: β = ±50° (Excluding dead zone) Dead zone: β = ±8° (There are some areas in which decoding fails due to specular reflection) (Depth of field: Within 90 mm from the minimum scannable distance).

Dead a rea

Figure 5: Skew and dead zone

Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance:

90 mm from the edge of the data collector

Label:

Pitch, Skew Angle PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2.5 Dead Zone, Tilt Angle PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm

Angle:

Curvature: R = ∞, Skew Angle = β +15° (for measuring Pitch Angle and Tilt Angle)

13

Page 14

Opticon OPL 9728 Specifications Manual

γ=20 ° γ=20 °

8.4.3. Tilt Angle γ = ±20°

Figure 6: Tilt angle

Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance:

90 mm from the edge of the data collector

Label:

Pitch, Skew Angle PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2.5 Dead Zone, Tilt Angle PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm

Angle:

Curvature: R = ∞, Skew Angle = β +15° (for measuring Pitch Angle and Tilt Angle)

14

Page 15

Opticon OPL 9728 Specifications Manual

8.5. Curvature With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R≥15 mm. With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R≥20 mm.

Figure 7: Curvature

Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm Distance:

90 mm from the edge of the data collector

Angle:

Skew Angle β = +15°

The scanning range will vary according to the depth of field.

15

Page 16

Opticon OPL 9728 Specifications Manual

9. Interface Specifications 9.1. Infrared Transmission (IrDA) 9.1.1. Specifications The dedicated cradle enables the OPL 9728 to perform infrared transmission of data with IrDA Ver1.2 low power specification. 9.1.2. Transmission Speed Default transmission speed is set at 115.2 kbps. However, you can easily change the transmission rate to 57.6 kbps, 38.4 kbps, 19.2 kbps, 9600 bps, 4800 bps, or 2400 bps.

10. Serial Number The serial number shown below is affixed to the back of the OPL 9728.

Figure 8: Serial number diagram

Uppercase: Management Barcode (Symbology: Code 39, Resolution: 0.12 to 0.2, N/W Ratio: 1:2.5 to 1:3) Lowercase: Model Names, Serial Numbers (The height of letters is 1.2 ± 0.3) Serial numbers are seven-digit numbers and start from number 0000001 regardless of batch.

16