The text of a manual · part 2 of 3
OPL 9728 Specifications Manual, pages 9 to 16
Pages 9 to 16 of 22
The original document is the PDF (644 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Opticon OPL-9728
Page 9
Opticon OPL 9728 Specifications Manual
7. Optical Specifications 7.1. Laser Scan Specifications Parameter
Specification
Unit
Light-emitting element
Red laser diode, Emission wavelength
650 ±10 (25° C)
nm
Light output
1.0 or less mW
Scanning method
Bi-directional scanning, Scanning speed
100 ±20 scans/s
Scan angle
Scan angle: 54 ±5
°
Read angle: 44 (Min)
°
Note: Refer to chapter 8, “Technical Specifications,” to read about scanning performance.
7.2. Laser Scan Standards 7.2.1. Laser Scan Tilt Maximum tilt between both ends of laser scan line. Less than 1.2° upward tilt from the scan origin. Maximum of 3.1 mm when measured at a point 150 mm away from the scan origin. (The skew angle of this measurement was 0°.) Measurement was done from the center of the scan line.
9
Page 10
Opticon OPL 9728 Specifications Manual
7.2.2. Scan Curvature Maximum gap between the straight line connecting both ends of laser scan line and the actual laser scan line. Less than 1.27° curvature from the scan origin. Maximum of 3.3 mm curvature when measured at a point 150 mm away from the scan origin. Measurement was done from the center of the scan line.
Figure 2: Scan tilt and curvature
8. Technical Specifications The conditions for technical specifications are as follows, unless otherwise specified in each section. Conditions Ambient temperature and humidity:
Room temperature (5 to 35º C) Room humidity (45% to 85% RH)
Ambient light:
500 to 900 lx
Background:
Barcode = black Space = white Margin = white Background of label = black
8.1. Print Contrast Signal (PCS) 0.45 or higher (over 70% of reflectivity of space and quiet zone). PCS= Scanning performance may decline if dirt or scratches mar the optical window. Keep the optical window clean.
8.2. Minimum Resolution 0.15 mm
10
Page 11
Opticon OPL 9728 Specifications Manual
8.3. Scan Area and Resolution
Reso lu t ion 0 .15 Reso lu t ion 0 .25
Reso lu t ion 0 .5 Reso lu t ion 1 .0
Figure 3: Depth of field
Symbology
Resolution (mm)
Decode Depth (mm)
PCS
Code 39
1.0
60–300
0.9
Code 39
0.5
35–210
0.9
Code 39
0.25
35–120
0.9
Code 39
0.15
35–70
0.9
Barcode Sample: OPTOELECTRONICS Test Sample N/W ratio:
1:2.5
Angle:
α = 0°, β = 15°, γ = 0°
Curvature:
R=∞
11
8 TUV
0 -
7PQRS
.*...
ENT
3DEF 2 ABC
5 JKL
6MNO
CLR BS
1
4GH I
Sh i f t
M in mu i m read ing d is tance
Conditions
9WXYZ
40 35
60 52
44゚
75
145
240
365
8.3.1. Depth of Field The depth of field is measured from the edge of the data collector. The scanning range is within the circular arc centered on the scan origin.
Page 12
Opticon OPL 9728 Specifications Manual
Resolution
Symbology
PCS
Quiet Zone
Digit
1.0 mm
Code 39
0.9
25 mm
1
0.5 mm
Code 39
0.9
18 mm
3
0.25 mm
Code 39
0.9
10 mm
8
0.15 mm
Code 39
0.9
7 mm
10
Note: dirt or scratches on the mask will degrade scanning performance. Always handle the data collector carefully.
8.4. Pitch, Skew, and Tilt 8.4.1. Pitch Angle α = ±25°
Figure 4: Pitch
Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance:
90 mm from the edge of the data collector
Label:
Pitch, Skew Angle PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2.5 Dead Zone, Tilt Angle PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm
Angle:
Curvature: R = ∞, Skew Angle = β +15° (for measuring Pitch Angle and Tilt Angle)
12
Page 13
Opticon OPL 9728 Specifications Manual
β=5 0゚
8゚
8゚
0゚ β=5
8.4.2. Skew Angle and Dead Zone Skew angle: β = ±50° (Excluding dead zone) Dead zone: β = ±8° (There are some areas in which decoding fails due to specular reflection) (Depth of field: Within 90 mm from the minimum scannable distance).
Dead a rea
Figure 5: Skew and dead zone
Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance:
90 mm from the edge of the data collector
Label:
Pitch, Skew Angle PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2.5 Dead Zone, Tilt Angle PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm
Angle:
Curvature: R = ∞, Skew Angle = β +15° (for measuring Pitch Angle and Tilt Angle)
13
Page 14
Opticon OPL 9728 Specifications Manual
γ=20 ° γ=20 °
8.4.3. Tilt Angle γ = ±20°
Figure 6: Tilt angle
Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance:
90 mm from the edge of the data collector
Label:
Pitch, Skew Angle PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2.5 Dead Zone, Tilt Angle PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm
Angle:
Curvature: R = ∞, Skew Angle = β +15° (for measuring Pitch Angle and Tilt Angle)
14
Page 15
Opticon OPL 9728 Specifications Manual
8.5. Curvature With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R≥15 mm. With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R≥20 mm.
Figure 7: Curvature
Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm Distance:
90 mm from the edge of the data collector
Angle:
Skew Angle β = +15°
The scanning range will vary according to the depth of field.
15
Page 16
Opticon OPL 9728 Specifications Manual
9. Interface Specifications 9.1. Infrared Transmission (IrDA) 9.1.1. Specifications The dedicated cradle enables the OPL 9728 to perform infrared transmission of data with IrDA Ver1.2 low power specification. 9.1.2. Transmission Speed Default transmission speed is set at 115.2 kbps. However, you can easily change the transmission rate to 57.6 kbps, 38.4 kbps, 19.2 kbps, 9600 bps, 4800 bps, or 2400 bps.
10. Serial Number The serial number shown below is affixed to the back of the OPL 9728.
Figure 8: Serial number diagram
Uppercase: Management Barcode (Symbology: Code 39, Resolution: 0.12 to 0.2, N/W Ratio: 1:2.5 to 1:3) Lowercase: Model Names, Serial Numbers (The height of letters is 1.2 ± 0.3) Serial numbers are seven-digit numbers and start from number 0000001 regardless of batch.
16