The text of a manual · part 3 of 4
NLV 1001 Compact Fixed Position Laser Barcode Scanner Specification Manual, pages 21 to 30
Pages 21 to 30 of 40
The original document is the PDF (970 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Opticon NLV-1001
Page 21
Opticon NLV 1001 Specification Manual
8.3. DOS/V Wedge Interface Specification 8.3.1. Connectors
Figure 18: Connector (host side)
Figure 19: Connector (keyboard side)
Contact Number
Host Side
Keyboard Side
1
CPU DATA
KEY DATA
2
OPEN
OPEN
3
GND
GND
4
VCC
VCC
5
CPU CLOCK
KEY CLOCK
6
OPEN
OPEN
Set the language for the scanner and PC keyboard to the same language before use; otherwise, the output may not be correct. Do not use the host keyboard while data is being transmitted to the host, or the data may be transmitted incorrectly.
21
Page 22
Opticon NLV 1001 Specification Manual
8.4. Scan Area and Resolution The depth of field is measured from the edge of the scanner. The scanning range is within the circular arc centered on the scan origin.
Figure 20: Scan area and resolution
PCS
0.9
Resolution (mm)
Decode Depth (mm)
1.0
70–630
0.5
50–400
0.25
50–240
0.15
50–130
0.127
60–100
22
Page 23
Opticon NLV 1001 Specification Manual
Resolution
Symbology
PCS
Quiet Zone
Digit
1.0 mm
CODE-39
0.9
25 mm
1
0.5 mm
CODE-39
0.9
18 mm
3
0.25 mm
CODE-39
0.9
10 mm
8
0.15 mm
CODE-39
0.9
7 mm
10
0.127 mm
CODE-39
0.9
5 mm
4
Conditions: Barcode Sample: OPTOELECTRONICS Test Sample N/W Ratio:
1:2.5
Angle:
α = 0°, β = 15°, γ = 0°
Curvature:
R=∞
8.5. Pitch, Skew, and Tilt (PCS) 8.5.1. Pitch Angle α = ±35°
Figure 21: Pitch
23
Page 24
Opticon NLV 1001 Specification Manual
8.5.2. Skew Angle and Dead Zone Skew angle: β = ±50° (Excluding dead zone) Dead zone: β = ±8 °(Areas in which decoding fails due to specular reflection)
Figure 22: Skew angle and dead zone
24
Page 25
Opticon NLV 1001 Specification Manual
8.5.3. Tilt Angle γ = ±20°
Figure 23: Tilt angle
Conditions: Barcode Sample: OPTOELECTRONICS Test Sample Distance:
100 mm from the edge of the scanner
Label:
Pitch Angle, Skew Angle, Dead Zone PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code-39, Quiet Zone = 10 mm, N/W Ratio = 1:2.5 Tilt Angle PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm
Angle:
Curvature: R = ∞, Skew Angle β = +15° (for measuring pitch angle and tilt angle)
25
Page 26
Opticon NLV 1001 Specification Manual
8.6. Curvature With 8-digit JAN barcodes, decoding performance is guaranteed when R ≥ 15 mm. With 13-digit JAN barcodes, decoding performance is guaranteed when R ≥ 20 mm.
Figure 24: Curvature
Conditions: Barcode Sample: OPTOELECTRONICS Test Sample PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm Distance:
100 mm from the edge of the scanner
Angle:
Skew angle: β = +15°
26
Page 27
Opticon NLV 1001 Specification Manual
9. Cable and Connector 9.1. RS-232C Cable 9.1.1. Standard Specification Type:
Straight
Diameter:
φ3.8±0.5 mm
Length:
1500±50 mm
Cores:
8 insulated wires, 1 conductive wire
Weight:
Approximately 45 g
Figure 25: RS-232C cable (standard)
9.1.2. D-sub Specification) Type:
Straight
Diameter:
φ3.8±0.5 mm
Length:
1500±50 mm or 500±50 mm
Cores:
8 insulated wires, 1 conductive wire
Weight:
Approximately 65 g
Figure 26: RS-232C cable (D-sub)
27
Page 28
Opticon NLV 1001 Specification Manual
9.2. USB Cable (Standard specification) Type:
Straight
Diameter:
φ3.8 ±0.5 mm
Length:
1500 ±50 mm
Cores:
4 insulated wires, 1 conductive wire
Weight:
Approximately 50 g
Figure 27: USB cable
9.3. Wedge Cable (Standard specification) Type:
Y cable
Diameter:
φ3.8 ±0.5 mm
Length:
1500 ±50 mm
Cores:
6 insulated wires, 1 conductive wire
Weight:
Approximately 60 g
#1O
#1
Figure 28: Wedge cable
28
Page 29
Opticon NLV 1001 Specification Manual
9.4. Connector Specification (Scanner Side) CN1 (10-pin) Pin #
Specifications RS-232C
USB
WEDGE
1
TRIGGER
NC
NC
2
OK
NC
NC
3
NG
NC
NC
4
CTS
NC
KEY DATA
5
RTS
NC
KEY CLOCK
6
RxD
USB-
CPU DATA
7
TxD
USB+
CPU CLOCK
8
VCC
VCC
VCC
9
GND
GND
GND
10
SHIELD
SHIELD
SHIELD
10. Default Settings 10.1. Barcodes Default menu barcodes set the scanner to factory defaults. RS-232C Functions
Menu labels
Menu codes
SET
_ZZ_ _U2_ _ZZ_
ZZ
RS-232C END
U2 ZZ
USB-HID Functions
Menu labels
Menu codes
SET
_ZZ_ _SU_ _ZZ_
ZZ
USB-HID END
SU ZZ
29
Page 30
Opticon NLV 1001 Specification Manual
USB-VCP A driver is required and can be downloaded from Opticon’s support Web site: http://opticonfigure.opticon.com/. Functions
Menu labels
Menu codes
SET
_ZZ_ _C01_ _ZZ_
ZZ
USB-VCP END
C01 ZZ
Wedge (with keyboard) Functions
Menu labels
Menu codes
SET
_ZZ_ _UB_ _KM_ _ZZ_
ZZ
AT-Wedge With keyboard END
UB KM ZZ
Wedge (without keyboard) Functions
Menu labels
Menu codes
SET
_ZZ_ _UB_ _KL_ _ZZ_
ZZ
AT-Wedge Without keyboard END
UB KL ZZ
30