Page 31
Opticon NLV 1001 Specification Manual
10.2. Default Settings 1: Readable Codes Code type
Reading
Transmit Code Length
Transmit CD
Calculate CD
Prefix
Suffix
Transmit Other
Remarks
UPC-A
„
X
„
„
-
CR
UPC-A Add-on
X
X
„
„
-
CR
UPC-E
„
X
„
„
-
CR
UPC-E Add-on
X
X
„
„
-
CR
EAN-13
„
X
„
„
-
CR
EAN-13 Add-on
X
X
„
„
-
CR
EAN-8
„
X
„
„
-
CR
EAN-8 Add-on
X
X
„
„
-
CR
Code-39
„
X
„
X
-
CR
Not transmit ST/SP
Intercharacter gap check ≤ *1
Code-39 Trioptic
„
X
„
X
-
CR
Not transmit ST/SP
NW-7 (CODABAR)
„
X
„
X
-
CR
Not transmit ST/SP
Industrial2of5
„
X
„
X
-
CR
Interleaved2of5
„
X
„
X
-
CR
Code-93
„
X
X
„
-
CR
Code-128
„
X
X
„
-
CR
EAN-128
X
X
X
„
-
CR
S-Code
„
X
„
X
-
CR
MSI/Plessey
„
X
„CD1
„CD1
-
CR
UK/Plessey
„
X
„
„
-
CR
Telepen
„
X
„
„
-
CR
Matrix20f5
X
X
„
X
-
CR
Chinese Post Matrix 2of5
X
X
„
X
-
CR
IATA
„
X
„
X
-
CR
RSS-14
X
X
„
„
-
CR
RSS-Limited
X
X
„
„
-
CR
RSS-Expanded
X
X
„
„
-
CR
PDF417
X
X
-
-
-
CR
MicroPDF417
X
X
-
-
-
CR
CODE-11
X
X
X
„
-
CR
31
Page 32
Opticon NLV 1001 Specification Manual
Notes: •
In the “Reading” column, “„” means “enable reading” and “X” means “disable reading.”
•
In the “Transmit Code Length” column, “„” means “transmit code length” and “X” means “do not transmit code length.”
•
In the “Transmit CD” column, “„” means “transmit check digit” and “X” means “do not transmit check digit.”
•
In the “Calculate CD” column, “„” means “calculate check digit” and “X” means “do not calculate check digit.”
10.3. Default Settings 2: Read Options, Trigger, Buzzer Item
Default Setting
Setting the number of characters
Fixed length OFF all codes
Read mode
Multiple read
Multiple read reset time
500 ms
Add-on wait mode
500 ms
Multiple label read
Disable
Multiple column read
Disable
Redundancy
Default option ([X0] setting)
Read 1 times, redundancy = 0
Other options ([X1 .. X3] setting) ([BS .. BW] setting)
Read n times, redundancy = n+1 for following symbologies and lengths: ● Code39 with length <= 5 ● MSI/Plessey with length <= 4 ● IATA,Industrial 2of5, Interleaved 2of5 with length <= 8 ● Matrix 2of5 (& Chin.Post), Scode with length <= 8 ● Codabar (NW7) with all lengths ● Code-11 with length <= 5
Trigger switch
Enable
Trigger repeat
Disable
Auto trigger
Disable
Read time
2 seconds
Margin check
Normal
Buzzer duration
50 ms
Buzzer tone
Single tone (3 kHz)
Buzzer loudness
Maximum
Buzzer transmission
Before transmission
Startup buzzer
Enable
Good read LED
Indicator duration 200 ms
32
Page 33
Opticon NLV 1001 Specification Manual
11. Product Labeling 11.1. Serial Number The serial number shown below is affixed to the scanner.
Figure 29: Serial number diagram
11.2. FCC Label
Figure 30: FCC label
33
Page 34
Opticon NLV 1001 Specification Manual
12. Packaging Specifications 12.1. Individual Packaging Specification Put the scanner in a protective foam bag and place it in a single packing box. Size of the package (after assembly): 245 (W) X 110 (D) X 38 (H) mm
12.2. Collective Packaging Specification BOX for MSH-110 (B85006-15B) Rows
Carton Box (5B0008 )
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩
Packaged 50 sets into the Carton-Box.
① ⑥
②
⑦
④
⑨ Ro
1~ 5 5 ~10 11 ~15 16 ~20 21 ~25 26 ~30 31 ~35 36 ~40 41 ~45 46 ~50
③
⑧
Ro
The order of serial - No.
⑩
⑤
Ro-30 Label (NFT2100-7070-0-00)
5 Steps
① -1 ① -2 ① -3 ① -4 ① -5
* Stick 〝Ro-30〟Label onto one side only.
Figure 31: Packaging the NLV 1001
Note: The “Ro” mark on inner and outer packaging is to notify that this product does not use any material, components, or parts that are restricted under RoHS. However, this document does not have any legal weight in the European Union.
34
Page 35
Opticon NLV 1001 Specification Manual
13. Durability 13.1. Electrical Noise No malfunction occurred when sinusoidal electrical noise (50Hz -100kHz, < 0.1Vpp) was added to the power supply line. Conditions: Barcode Sample: OPTOELECTRONICS Test Sample PCS:
0.9
Resolution:
0.25 mm
Symbology:
9-digit Code-39
Quiet Zone:
10 mm
N/W Ratio:
1:2.5
Distance:
150 mm
Angle:
α = 0° β = 15° γ = 0°
Curvature:
R=∞
Power Supply Voltage:
5.0 V
13.2. Shock No malfunction occurred after the following drop test. Drop Test: Dropped the scanner from the 75 centimeter above the concrete floor (once in each of 5 directions).
13.3. Vibration No malfunction occurred after the following vibration test. Vibration Test: Increase the frequency of the vibration from 12Hz to 100Hz with accelerated velocity 19.6m/s2 (2G) for 60 minutes in non-operating state. Repeat this routine in each X, Y, Z direction once for 60 minutes each.
13.4. Static Electricity Aerial discharge
8kV Max. (No malfunction) 10kV Max. (No destruction)
Measurement environment
Use electrostatic testing device compliant with IEC 61000-4-2
Discharge resistance:
330Ω
Capacitor charging:
150pF
13.5. Other Dust and drip proof
IEC IP43
Cable bending resistance is not warrantable.
35
Page 36
Opticon NLV 1001 Specification Manual
14. Reliability MTBF (mean time between failures) of this product except for the laser diode and the mirror motor scan unit is 30,000 hours. Life cycle of the laser diode is 10,000 hours and that of the mirror motor scan unit is also 10,000 hours. The estimate of MTBF and product life cycle is based on standard operation of the product within the recommended temperature range and without extreme electronic or mechanical shock.
15. Auto Trigger (Option) The NLV 1001 has an optional auto trigger setting, which starts barcode reading automatically by using sensor detection. The scanner starts barcode reading after detecting reflection from the surface when the auto trigger is used. Auto trigger distance: 50 ±10 mm from the edge of the scanner. Conditions: Moving speed:
100 ±10 mm/s
Angle:
Vertical to the edge of the scanner
Environmental temperature and humidity:
Room temperature and humidity
Environmental illuminance:
500 to 900 lx
Conditions for the auto trigger:
1. Barcode sheet: OPTOELECTRONICS Test Sheet (white) Background: OPTOELECTRONICS Test Sheet (black) 2. Barcode sheet: OPTOELECTRONICS Test Sheet (black) Background: OPTOELECTRONICS Test Sheet (white)
36
Page 37
Opticon NLV 1001 Specification Manual
Figure 32: Auto trigger
15.1. Auto Trigger Settings Functions SET Disable auto trigger Enable auto trigger END
Menu labels
Menu codes
_ZZ_ _+F_ _+I_ _ZZ_
ZZ +F +I ZZ
37
Page 38
Opticon NLV 1001 Specification Manual
16. Regulatory Compliance 16.1. Laser Safety The scanner emits laser beams. Class 1 laser devices are not considered to be hazardous when used for their intended purpose. Avoid staring into the laser beam. IEC60825-1+A2: 2001 Class 1 JIS-C-6802: 2005 Class 1 FDA CDRH Laser Class 1. Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice No. 50 dated July 26, 2001.
16.2. Product Safety EN60950-1: 2001 IEC60950-1: 2001
16.3. EMC EN55022 EN55024 VCCI Class B: This is a Class B product, to be used in a domestic environment based on the Technical Requirement of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Please install and use the equipment according to the instruction manual. FCC Part 15 Subpart B Class B: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
16.4. RoHS RoHS: The restriction of the use of certain hazardous substances in electrical and electronic equipment, 2002/95 EC
38
Page 39
Opticon NLV 1001 Specification Manual
17. Safety Handle this product carefully. Do not deliberately subject it to any of the following.
17.1. Shock •
Do not throw or drop the scanner.
•
Do not place heavy objects on the cables.
17.2. Temperature Conditions •
Do not use the scanner at temperatures outside the specified range.
•
Do not pour boiling water on the scanner.
•
Do not throw the scanner into the fire.
•
Do not forcibly bend the cables at low temperatures.
17.3. Foreign Materials •
Do not immerse the scanner in liquids.
•
Do not subject the scanner to chemicals.
17.4. Other •
Do not plug/unplug the connectors before disconnecting the power.
•
Do not disassemble this product.
•
Do not use the scanner near a radio or a TV receiver. It may cause reception problems.
•
The scanner may be damaged by voltage drops.
•
The scanner may not perform properly in environments when placed near a flickering light, such as a computer monitor, television, etc.
39
Page 40
Opticon NLV 1001 Specification Manual
18. Mechanical Drawing Dimensions: 30 X 20 X 43.3 mm (cable not shown)
Figure 33: Mechanical drawing
40