Page 11
Opticon NLV 1001 Specification Manual
(2) DC Jack Pin
Signal
Remarks
1
VCC
Inside
2
GND
Outside
8.1.4. Interface Circuit
Figure 2: Interface circuit
11
Page 12
Opticon NLV 1001 Specification Manual
8.1.5. Character Format
Figure 3: Character format (same for both sending and receiving)
8.1.6. Communication Format
Figure 4: Communication format
8.1.7. Handshaking Select handshaking options using the menu or command listed below. Handshaking
Menu/Command
No handshake
P0
BUSY/READY
P1
MODEM
P2
ACK/NAK
P3
ACK/NAK NO RESPONSE
P4 a) No Handshake The scanner attempts the communication regardless of the state of the host computer.
Figure 5: No handshaking
12
Page 13
Opticon NLV 1001 Specification Manual b) BUSY/READY The scanner and the host computer notify each other of their state and whether they can receive data with BUSY/READY through an RS line. They can communicate state to each other through a CTS line when connected as in the following figure.
Figure 6: Busy/Ready communication
The scanner stays ON (is able to receive data) except during certain parts of the process, such as receiving data (buzzer command execution), transmitting data, and menu processing. The scanner checks the CTS line before transmitting data. When it is ON, the scanner transmits data. When it is OFF, the scanner waits for it to turn ON within a set time. The scanner will abort transmission with an error indication (buzzer) when the CTS line is not ON within a specified period. The Flow Control time-outs are as follows, and the default setting is “indefinitely“ (I0). Flow Control Time Out
Menu/Command
Indefinitely
I0
100 ms
I1
200 ms
I2
400 ms
I3
13
Page 14
Opticon NLV 1001 Specification Manual
Figure 7: Cannot receive command
CTS, T×D signals timing When the CTS line is turned OFF while sending a T×D signal, the scanner transmits one character and waits. When the CTS signal is turned ON while transmitting a character, the character will be transmitted.
Figure 8: Signal timing Note: When using loopback (wire connection) for RTS, CTS line of the scanner in this setting, No handshake is not enabled.
14
Page 15
Opticon NLV 1001 Specification Manual c) MODEM The scanner turns the RTS line ON before transmitting data. Other processes are the same as BUSY/READY.
Figure 9: Handshaking - modem
15
Page 16
Opticon NLV 1001 Specification Manual d) ACK/NAK After data has been transmitted, the scanner expects to receive one of the following responses from the host: •
ACK response - Action: The scanner completes transmission with the good-read buzzer and returns to the initial state.
•
NAK response - Action: The scanner sends the data again and waits for the response from the host.
•
DC1 response - Action: The scanner returns to waiting for the trigger, if it has a trigger (the initial state).
•
None response - Action: The scanner sounds the error buzzer and returns to the initial state.
ACK/NAK timeout can be set as follows using the menu or commands. •
I4: Indefinitely (default)
•
I5: 100 ms
•
I6: 500 ms
•
I7: 1000 ms
Figure 10: Handshaking - ACK/NAK
16
Page 17
Opticon NLV 1001 Specification Manual e) ACK/NAK - NO RESPONSE When no response from the host is received within the setting time, the scanner assumes an ACK response, and returns to the initial state without the error buzzer. The other actions are the same as ACK/NAK.
Figure 11: Handshaking - ACK/NAK, no response
17
Page 18
Opticon NLV 1001 Specification Manual
8.1.8. OK/NG Signal (NLV 1000 RS-232C Standard Only) The output ON/OFF or the logic can be selected by the menus or commands listed below. Functions
Menu/Command
SYNC Synchronous H active
X*C (default)
SYNC Synchronous L active
X*D
One shot H active
X*E
One shot L active
X*F
One shot time 10 ms
X*G
One shot time 20 ms
X*H
One shot time 30 ms
X*I
One shot time 40 ms
X*J
One shot time 50 ms
X*K
One shot time 60 ms
X*L
One shot time 70 ms
X*M
One shot time 80 ms
X*N
One shot time 90 ms
X*O
One shot time 100 ms
X*P (default)
Enable sequence output
X*Q (default)
Disable sequence output
X*R
The following figures show examples of output timing when using a pull-up resistor, since the OK/NG output is the FET open drain output.
a) Good Read (Synchronous)
Figure 12: Good read (synchronous)
18
Page 19
Opticon NLV 1001 Specification Manual b) Read Error within Specified Time (Synchronous)
Figure 13: Read error (synchronous)
c) Good Read (One Shot)
Figure 14: Good read (one shot)
d) Read Error within Specified Time (One Shot)
Figure 15: Read error (one shot)
19
Page 20
Opticon NLV 1001 Specification Manual
8.2. USB Interface Specifications 8.2.1. Interface The interface is full-speed USB 1.1. 8.2.2. Connectors a) USB "A" Connector
Figure 16: USB "A" connector
Contact Number
Signal Name
1
VCC
2
-DATA
3
+DATA
4
GND
Do not use the host keyboard while data is being transmitted to the host, or the data may be transmitted incorrectly. 8.2.3. Interface Circuit
Figure 17: Interface circuit
20