The text of a manual · part 14 of 16
Universal menu book: bar code configuration and commands manual, pages 131 to 140
Pages 131 to 140 of 151
The original document is the PDF (662 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Opticon NFT-2100, Opticon NFT-7175 and Opticon OPT-6125
Page 131
OPTICON Universal menu book
6.1. Buzzer settings These options determine the buzzer type, tone, duration and loudness. The buzzer tone and loudness are reader dependent due to different buzzer types. Buzzer type: The buzzer may be disabled or enabled as either a hardware or software buzzer. Not all readers support both a hardware and software buzzer. Buzzer tone: If a software buzzer is used, the buzzer tone may be selected as shown in figure 6.01.
Buzzer after transmission: The good read buzzer will be activated after transmission. Enable startup buzzer: When this options is selected, the reader will generate a single good read buzzer to indicate the reader is ready after the reader is supplied with power. Disable startup buzzer: When this options is selected, the reader will not sound the buzzer after the reader is supplied with power.
Buzzer duration and loudness: If a software buzzer is used, a buzzer duration of 50, 100, 200 or 400 msec. may be selected. The loudness can be adjusted in four different steps.
Fig. 6.01. Buzzer Settings Frequency
Buzzer
Buzzer before transmission: The good read buzzer will be activated after decoding the bar code, but before transmission. During the transmission the buzzer sequence will be completed.
Single tone
3 KHz
100%
High - low
3 KHz - 2.5 KHz
50% - 50%
Low - high
3 KHz - 4 KHz
50% - 50%
SET
_ZZ_
Disable buzzer
W0
_W0_
Enable buzzer
W8
_W8_
Single tone buzzer
W1
_W1_
High - low buzzer
W2
_W2_
END
_ZZ_
U124
Duration
Page 132
OPTICON Universal menu book
_ZZ_
Low - high buzzer
W3
_W3_
Buzzer duration 50 msec
W7
_W7_
Buzzer duration 100 msec
W4
_W4_
Buzzer duration 200 msec
W5
_W5_
Buzzer duration 400 msec
W6
_W6_
Buzzer loudness: Maximum
T0
_T0_
Buzzer loudness: Loud
T1
_T1_
Buzzer loudness: Normal
T2
_T2_
Buzzer loudness: Minimum
T3
_T3_
Buzzer before transmission
VY
_VY_
Buzzer after transmission
VZ
_VZ_
Disable startup buzzer
GD
_GD_
Enable startup buzzer
GC
_GC_
END
_ZZ_
U125
6 Indicator options
SET
Page 133
OPTICON Universal menu book
6.2. Good read LED The Good Read LED can be disabled or set for several durations.
SET
_ZZ_
Disable indicator
T4
_T4_
Indicator duration: 0.2 s
T5
_T5_
Indicator duration: 0.4 s
T6
_T6_
Indicator duration: 0.8 s
T7
_T7_
END
_ZZ_
U126
Page 134
OPTICON Universal menu book
7.1. Diagnostics
7. MISCELLANEOUS
The options in this part are primarily intended for diagnostic purposes. The following options are available: Transmit software version: The software version is transmitted. Transmit ROM checksum: The software calculated checksum over the internal program is transmitted. Transmit settings: The reader settings are transmitted as a string of hexadecimal numbers. Transmit ASCII printable string: The printable ASCII characters Hex 20 upto Hex 7F are transmitted. Transmit ASCII control string: The non printable ASCII control characters Hex 00 upto Hex 1F are transmitted.
_ZZ_
Transmit software version
Z1
_Z1_
Transmit ROM checksum
ZY
_ZY_
Transmit settings
Z3
_Z3_
Transmit ASCII printable string
ZA
_ZA_
Transmit ASCII control string
YV
_YV_
END
_ZZ_
U127
Miscellaneous
SET
7
Page 135
OPTICON Universal menu book
7.2. Serial configuration support Disable configuring via RS232: The reader ignores all configuration commands from the RS232 port. The trigger and buzzer commands are still accepted. Enable configuring via RS232: The reader accepts all configuration commands from the RS232 port. Disable trigger via RS232: The reader ignores the trigger command, <Z> (Hex 5A), via the RS232 port. Enable trigger via RS232: The reader accepts the trigger command via the RS232 port. Disable buzzer via RS232: The reader ignores the buzzer command via the RS232 port. Enable buzzer via RS232: The reader accepts the buzzer command, <B> (Hex 42) for the good read buzzer and <E> (Hex 45) for the error buzzer, via the RS232 port. Disable Good read LED via RS232: The reader ignores the good read LED command via the RS232 port.
Error message - No label: Following this menu label a maximum of 4 direct input characters may be read. These characters will be transmitted if during the read time of the reader no label was detected. This function is only available on readers where the trigger is enabled. If no direct input character is read following the command, the error message is disabled. The function may be combined with 'Error message - No decode'. Error message - No decode: Following this menu label a maximum of 4 direct input characters may be read. These characters will be transmitted if during the read time of the reader a label was detected, but nothing could be decoded. This function is only available on readers where the trigger is enabled. If no direct input character is read following the command, the error message is disabled.The function may be combined with 'Error message - No label'. Example: The following two examples will set the messages 'NL<CR>' and 'ND<CR>' for No label and No decode respectively. The two examples may both be active at the same time. See figure 7.01.
Enable Good read LED via RS232: The reader accepts the good read LED command, <L>(Hex 4C), via the RS232 port.
Fig. 7.01. Serial configuration support
Disable ACK/NAK for RS232 commands: The reader does not transmit <ACK> nor <NAK> when a command is received. Enable ACK/NAK for RS232 commands: The reader transmits an <ACK> (Hex 06) after each valid RS232 command and a <NAK> (Hex 15) after each invalid RS232 command. Enable/disable laser commands: The laser will not turn on when the trigger button is pressed or the trigger command is sent.
U128
SET
SET
Error - No label
Error - No decode
N
N
L
D
<CR>
<CR>
END
END
Page 136
OPTICON Universal menu book
7.2. Serial configuration support
_ZZ_
Disable configuring via RS232
TS
_TS_
Enable configuring via RS232
TT
_TT_
Disable trigger via RS232
8B
_8B_
Enable trigger via RS232
8C
_8C_
Disable buzzer via RS232
WB
_WB_
Enable buzzer via RS232
WA
_WA_
Disable good read LED via RS232
TY
_TY_
Enable good read LED via RS232
TZ
_TZ_
Disable ACK/NAK for RS232 comm.
WD
_WD_
Enable ACK/NAK for RS232 comm.
WC
_WC_
Enable enable/disable laser
SR
_SR_
Disable enable/disable laser
SQ
_SQ_
Clear error messages No label and No decode
TG
_TG_
END
_ZZ_ U129
7 Miscellaneous
SET
Page 137
OPTICON Universal menu book
SET
_ZZ_
Error message No label
TH
_TH_
Error message No decode
TI
_TI_
END
_ZZ_
U130
Page 138
OPTICON Universal menu book
A. TROUBLE SHOOTING The trouble shooting diagram can be of help if your reader does not operate as expected. If any problem is not covered or solved with this diagram you need to contact your dealer. Whether the reader operates or not can be checked in the following way: • it should beep after the power has been switched ON • it should either react on a trigger(if any) or it should emit light at the scan side of the reader (LEDs) See figure A.01.
Fig. A.01. Trouble shooting
Reader operates?
Check cabling
No
Yes No Problems reading menu?
Reads bar codes?
Yes
No
Setup reader or contact dealer
No
Setup bar code options
Yes
Appendix
Garbage on screen? Yes
Setup reader interface
Scans SET/END?
No
Reads any label?
Yes
No
Reader defect contact dealer
Yes
Software and menu do not match. Use matching menubook
Low buzzer indicates unsupported option
U131
Page 139
OPTICON Universal menu book
B. GLOSSARY OF TERMS AIM: An acronym for Association for Automatic Identification and Mobility. This is referring to an organization that is an authority for standards for bar codes. ASCII: An acronym for American Standard Code for Information Interchange. This refers to a set of 128 characters that are standardized. These characters include all basic English characters, digits, punctuation characters and control characters. Bar: The dark element of a printed symbol. Bar code: An array of parallel rectangular bars and spaces which together represent data elements of characters in a particular symbology. The bars and spaces are arranged in a predetermined pattern, following unambiguous rules defined by the symbology. Bar code density: The number of bar code characters which can be represented in a linear unit of measure. Bar code density is often expressed in characters per inch. Bar code label: A label that carries a bar code and, optionally, other human-readable information; it can be affixed to an article. Bar code reader: A device used to scan and decode a bar code symbol. Bar width: The thickness of a bar measured from the edge closest to the symbol start character to the trailing edge of the same bar. Also known as element width.
Bluetooth: A wireless transmission protocol that uses radio frequency waves. More information on bluetooth can be found on the Internet site: http://www.bluetooth.org Bluetooth dongle: A device that converts electrical signals into radio frequency waves according to the bluetooth standard. CCD reader: A scanning device which uses the CCD technology. CCD is an acronym for Charge Coupled Device. Light from a lightsource within the CCD reader is reflected by a bar code label and falls on an array of light sensitive elements in the reader, the CCD. Whether the light is reflected depends on black or white parts of the bar code. The presence (or absence) of reflected light determines the presence (or absence) of electrical charge (electrons) in the distinct elements. The result is an electrical image of the bar code which can be used for further processing. Character: A single group of bars and spaces which represent an individual number, letter or punctuation mark. It is usually composed of six, seven or eight bits. Check digit: A character included within a symbol whose value is based, mathematically, on other characters within the symbol. It is used to perform a mathematical check to ensure the accuracy of the read. CMOS interface: A serial interface that typically is used between embedded devices. The CMOS standard defines a logical "1" level at the same level as the power supply of the electronic components that are used inside the device.
Baudrate: The rate at which data is transferred over a serial interface, expressed in bits per second. U132
Page 140
OPTICON Universal menu book
Emulation:
CMOS imager: A scanning device, which uses the CMOS technology. CMOS is an acronym for Complementary Metal Oxide Semiconductors. Light from a light source within the CMOS is reflected by a bar code label and falls on an array of light sensitive elements in the scanner, the CMOS sensor. Whether the light is reflected depends on black or white parts of the bar code. The presence (or absence) of reflected light determines the presence (or absence) of electrical charge (electrons) in the distinct elements. The result is an electrical image of the bar code, which can be used for further processing.
The imitation of all or part of one device by another so that the mimicking device can accept the same data and perform the same functions as the actual device. Enable: To enable an option means, to activate it. Error correction: The possibility to correct read errors in a bar code. Most 2D bar codes have extra information that allows correction of the bar code. This makes it possible to read (partly) damaged bar codes.
Composite code: A bar code label that consists of two parts of two different symbologies: a linear (1D) part and a composite (2D) part. The composite part holds meta information about the product (like manufacturing date, quantity, etc.), while the linear part holds the product identification code. Data:
Default: A standard option or parameter setting. Default settings are present in the memory of a device. If no other value or option is chosen within a program (or bar code menu), the default settings are automatically chosen. Disable: To disable an option means, to deactivate. ECC: An acronym for Error Correction Code. See error correction. ECI: An acronym for Extended Channel Interpretation. This refers to a method used in 2-dimensional bar codes to encode characters in other code sets then ASCII.
Relates to a symbol in which the data elements must be of specific length. Flow control: See handshaking. Format: A message or data structure that allows identification of control and data parts by their position within a frame. Handshaking: The initial exchange between two data communication systems prior to and during data transmission. The first unit sends a signal, then waits for an appropriate signal in response. A handshake method (such as XON/ XOFF), parity setting, number of data bits, and number of stop bits. GUI: This key is the Windows key on a Microsoft keyboard or the Command key on a Apple keyboard. HID: An acronym for Human Interface Device. Keyboard, mouse and barcode readers belong to this category.
U133
Appendix
Digital information.
Fixed length: