Page 121

OPTICON Universal menu book

5.1.1. Multiple read reset time This option can be used in conjunction with multiple read mode. • for Laser and CCD readers, it sets the time that the reader should be pointed away from the label before it can decode the same label again • for Image readers, it sets the number of frames that the reader should be pointed away from the label before it can decode the same label again Indefinitely means that the next bar code must always be different, during the time the bar code reader is triggered. For the image reader the multiple reset time is not measured in ms, but in frames. The duration of each frame is variable, and is dependent of the captured image. See figure 5.01.

Fig. 5.01. Multiple read reset time

Multiple read reset time

50 ms 100 ms 200 ms 300 ms 400 ms 500 ms 600 ms Indefinitely

SET

_ZZ_

50ms

AH

_AH_

100ms

AI

_AI_

200ms

AJ

_AJ_

300ms

AK

_AK_

400ms

AL

_AL_

500ms

AM

_AM_

600ms

AN

_AN_

Indefinitely

AG

_AG_

END

_ZZ_ U114

1 2 3 4 Frames 5 6 7 Indefinitely

Page 122

OPTICON Universal menu book

5.1.2. Quiet zone options With this option the reader can decode bar codes that have smaller start and/or end margins than specified for the symbology. Be careful when using this option. It may increase the possibility of partial reads and ghost reads. Do not use smaller margin checks then necessary. If possible replace the bar code labels by ones that have correct start and end margins.

_ZZ_

No margin check

YN

_YN_

Margin check 1/7 nominal

YO

_YO_

Margin check 2/7 nominal

YP

_YP_

Margin check 3/7 nominal

YQ

_YQ_

Margin check 4/7 nominal

YR

_YR_

Margin check 5/7 nominal

YS

_YS_

Margin check 6/7 nominal

YT

_YT_

Margin check normal

YU

_YU_

END

_ZZ_

U115

5 Read options

SET

Page 123

OPTICON Universal menu book

5.1.3. Auto trigger options

5.2. Read time options

These options are used to activate the auto trigger option of the reader. This is only supported for reader equipped with the auto trigger option.

The length of the period that the reader is ON after the trigger switch is pressed, or (in multiple or continuous read mode) after a label has been read. Selecting a read time of 0 means that the reader will stay ON as long as the trigger switch is being pressed. Selecting a read time for readers without a trigger switch, or when the trigger switch is disabled, does not have any effect.

Disable auto trigger: The auto trigger function is not activated. Enable auto trigger: The reader will be triggered if it detects changes in brightness. Enable stand detection: Support for this option is reader dependent and a suitable stand is required. This stand detection option enables auto trigger automatically when the reader is inserted into the stand. When the reader is removed from the stand, auto trigger is disabled. In case the option disable auto trigger or the the option enable autotrigger is configured the stand detection configuration is automatically disabled.

SET

_ZZ_

Disable auto trigger

+F

_+F_

Enable auto trigger

+I

_+I_

Enable stand detection

*4

_*4_

END

_ZZ_

U116

Page 124

OPTICON Universal menu book

5.2. Read time options

_ZZ_

0 seconds

Y0

_Y0_

1 second

Y1

_Y1_

2 seconds

Y2

_Y2_

3 seconds

Y3

_Y3_

4 seconds

Y4

_Y4_

5 seconds

Y5

_Y5_

6 seconds

Y6

_Y6_

7 seconds

Y7

_Y7_

8 seconds

Y8

_Y8_

9 seconds

Y9

_Y9_

Read time * 10

YL

_YL_

Indefinitely

YM

_YM_

END

_ZZ_

U117

5 Read options

SET

Page 125

OPTICON Universal menu book

5.3. Power control The motor options are only applicable for selected laser bar code readers and with trigger enabled. In case the read time is expired, the motor can be switched OFF. In case the trigger is activated, the motor is switched ON again. To reduce the start-up time of the motor, the motor can be configured to half speed in idle mode. The Auto shutoff time can be configured between 1 and 9999 seconds, by reading 1 up to 4 direct input numeric characters from chapter: String options. A value of 0 (default) means that the bar code reader enters the idle state if the read time has expired.

SET

_ZZ_

Disable motor when idle

4Z

_4Z_

Enable motor when idle

4Y

_4Y_

Motor half speed when idle

BBA

_BBA_

Auto shutoff time

BBB

_BBB_

END

_ZZ_

U118

Page 126

OPTICON Universal menu book

5.4. Redundancy This is the number of times that a label must be correctly decoded before it is transmitted. Selecting a higher redundancy count makes reading slower, but it reduces the probability of reading errors, especially when labels of poor definition are used.

_ZZ_

Read 1 time, redundancy = 0

X0

_X0_

Read 2 times, redundancy = 1

X1

_X1_

Read 3 times, redundancy = 2

X2

_X2_

Read 4 times, redundancy = 3

X3

_X3_

END

_ZZ_

U119

5 Read options

SET

Page 127

OPTICON Universal menu book

5.5. Positive and negative bar codes Usually bar codes are printed black on white, but sometimes white on black. These labels are called positive and negative respectively. In case the 'negative bar codes' option has been selected, positive labels may not be decoded anymore or with difficulty. This also applies to menu labels. To enable the reader to read positive labels again, a number of negative menu labels have been included.

SET

_ZZ_

Positive bar codes

V2

_V2_

Negative bar codes

V3

_V3_

Positive and negative bar codes

V4

_V4_

Positive bar codes

V2

_V2_

Positive and negative bar codes

V4

_V4_

SET / END

ZZ

_ZZ_

END

_ZZ_

U120

Page 128

OPTICON Universal menu book

5.6. Floodlight and aiming options The floodlight and aiming options affect the light source that illuminates the area of the bar code symbol. The floodlight illuminates the full area during image capturing. When the scannable area consists of a highly reflecting surface the floodlight might need to be disabled to prevent over-exposure.

If an aiming light is available, the bar code reader can generate an aiming pattern to help the user to target at the bar code symbol. The aiming pattern will only be visible between two image captures. The aiming pattern will be off when the floodlight is on. Disable floodlight: The option ‘disable floodlight’ does not illuminate the area of the bar code symbol during image capturing. Alternating floodlight: The option ‘alternating floodlight’ switches by turn between enabled and disabled floodlight.

_ZZ_

Disable floodlight

D3A

_D3A_

Enable floodlight

D39

_D39_

Alternating floodlight

D3B

_D3B_

END

_ZZ_

U121

Read options

SET

5

Page 129

OPTICON Universal menu book

U122

Page 130

OPTICON Universal menu book

6. INDICATOR OPTIONS This chapter describes the options for the Buzzer and Good Read LED.

6 Indicator options

U123