The text of a manual · part 13 of 16
Universal menu book: bar code configuration and commands manual, pages 121 to 130
Pages 121 to 130 of 151
The original document is the PDF (662 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Opticon NFT-2100, Opticon NFT-7175 and Opticon OPT-6125
Page 121
OPTICON Universal menu book
5.1.1. Multiple read reset time This option can be used in conjunction with multiple read mode. • for Laser and CCD readers, it sets the time that the reader should be pointed away from the label before it can decode the same label again • for Image readers, it sets the number of frames that the reader should be pointed away from the label before it can decode the same label again Indefinitely means that the next bar code must always be different, during the time the bar code reader is triggered. For the image reader the multiple reset time is not measured in ms, but in frames. The duration of each frame is variable, and is dependent of the captured image. See figure 5.01.
Fig. 5.01. Multiple read reset time
Multiple read reset time
50 ms 100 ms 200 ms 300 ms 400 ms 500 ms 600 ms Indefinitely
SET
_ZZ_
50ms
AH
_AH_
100ms
AI
_AI_
200ms
AJ
_AJ_
300ms
AK
_AK_
400ms
AL
_AL_
500ms
AM
_AM_
600ms
AN
_AN_
Indefinitely
AG
_AG_
END
_ZZ_ U114
1 2 3 4 Frames 5 6 7 Indefinitely
Page 122
OPTICON Universal menu book
5.1.2. Quiet zone options With this option the reader can decode bar codes that have smaller start and/or end margins than specified for the symbology. Be careful when using this option. It may increase the possibility of partial reads and ghost reads. Do not use smaller margin checks then necessary. If possible replace the bar code labels by ones that have correct start and end margins.
_ZZ_
No margin check
YN
_YN_
Margin check 1/7 nominal
YO
_YO_
Margin check 2/7 nominal
YP
_YP_
Margin check 3/7 nominal
YQ
_YQ_
Margin check 4/7 nominal
YR
_YR_
Margin check 5/7 nominal
YS
_YS_
Margin check 6/7 nominal
YT
_YT_
Margin check normal
YU
_YU_
END
_ZZ_
U115
5 Read options
SET
Page 123
OPTICON Universal menu book
5.1.3. Auto trigger options
5.2. Read time options
These options are used to activate the auto trigger option of the reader. This is only supported for reader equipped with the auto trigger option.
The length of the period that the reader is ON after the trigger switch is pressed, or (in multiple or continuous read mode) after a label has been read. Selecting a read time of 0 means that the reader will stay ON as long as the trigger switch is being pressed. Selecting a read time for readers without a trigger switch, or when the trigger switch is disabled, does not have any effect.
Disable auto trigger: The auto trigger function is not activated. Enable auto trigger: The reader will be triggered if it detects changes in brightness. Enable stand detection: Support for this option is reader dependent and a suitable stand is required. This stand detection option enables auto trigger automatically when the reader is inserted into the stand. When the reader is removed from the stand, auto trigger is disabled. In case the option disable auto trigger or the the option enable autotrigger is configured the stand detection configuration is automatically disabled.
SET
_ZZ_
Disable auto trigger
+F
_+F_
Enable auto trigger
+I
_+I_
Enable stand detection
*4
_*4_
END
_ZZ_
U116
Page 124
OPTICON Universal menu book
5.2. Read time options
_ZZ_
0 seconds
Y0
_Y0_
1 second
Y1
_Y1_
2 seconds
Y2
_Y2_
3 seconds
Y3
_Y3_
4 seconds
Y4
_Y4_
5 seconds
Y5
_Y5_
6 seconds
Y6
_Y6_
7 seconds
Y7
_Y7_
8 seconds
Y8
_Y8_
9 seconds
Y9
_Y9_
Read time * 10
YL
_YL_
Indefinitely
YM
_YM_
END
_ZZ_
U117
5 Read options
SET
Page 125
OPTICON Universal menu book
5.3. Power control The motor options are only applicable for selected laser bar code readers and with trigger enabled. In case the read time is expired, the motor can be switched OFF. In case the trigger is activated, the motor is switched ON again. To reduce the start-up time of the motor, the motor can be configured to half speed in idle mode. The Auto shutoff time can be configured between 1 and 9999 seconds, by reading 1 up to 4 direct input numeric characters from chapter: String options. A value of 0 (default) means that the bar code reader enters the idle state if the read time has expired.
SET
_ZZ_
Disable motor when idle
4Z
_4Z_
Enable motor when idle
4Y
_4Y_
Motor half speed when idle
BBA
_BBA_
Auto shutoff time
BBB
_BBB_
END
_ZZ_
U118
Page 126
OPTICON Universal menu book
5.4. Redundancy This is the number of times that a label must be correctly decoded before it is transmitted. Selecting a higher redundancy count makes reading slower, but it reduces the probability of reading errors, especially when labels of poor definition are used.
_ZZ_
Read 1 time, redundancy = 0
X0
_X0_
Read 2 times, redundancy = 1
X1
_X1_
Read 3 times, redundancy = 2
X2
_X2_
Read 4 times, redundancy = 3
X3
_X3_
END
_ZZ_
U119
5 Read options
SET
Page 127
OPTICON Universal menu book
5.5. Positive and negative bar codes Usually bar codes are printed black on white, but sometimes white on black. These labels are called positive and negative respectively. In case the 'negative bar codes' option has been selected, positive labels may not be decoded anymore or with difficulty. This also applies to menu labels. To enable the reader to read positive labels again, a number of negative menu labels have been included.
SET
_ZZ_
Positive bar codes
V2
_V2_
Negative bar codes
V3
_V3_
Positive and negative bar codes
V4
_V4_
Positive bar codes
V2
_V2_
Positive and negative bar codes
V4
_V4_
SET / END
ZZ
_ZZ_
END
_ZZ_
U120
Page 128
OPTICON Universal menu book
5.6. Floodlight and aiming options The floodlight and aiming options affect the light source that illuminates the area of the bar code symbol. The floodlight illuminates the full area during image capturing. When the scannable area consists of a highly reflecting surface the floodlight might need to be disabled to prevent over-exposure.
If an aiming light is available, the bar code reader can generate an aiming pattern to help the user to target at the bar code symbol. The aiming pattern will only be visible between two image captures. The aiming pattern will be off when the floodlight is on. Disable floodlight: The option ‘disable floodlight’ does not illuminate the area of the bar code symbol during image capturing. Alternating floodlight: The option ‘alternating floodlight’ switches by turn between enabled and disabled floodlight.
_ZZ_
Disable floodlight
D3A
_D3A_
Enable floodlight
D39
_D39_
Alternating floodlight
D3B
_D3B_
END
_ZZ_
U121
Read options
SET
5
Page 129
OPTICON Universal menu book
U122
Page 130
OPTICON Universal menu book
6. INDICATOR OPTIONS This chapter describes the options for the Buzzer and Good Read LED.
6 Indicator options
U123