The text of a manual · part 2 of 15
Opticon Universal Menu Book: bar code configuration and commands manual, pages 11 to 20
Pages 11 to 20 of 147
The original document is the PDF (593 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Opticon LG-K1WE5SP, Opticon 25-WEDGE-06 and Opticon HLT-1120 ELT-1120
Page 11
OPTICON UNIVERSAL MENU BOOK
1. Defaults
SET
_ZZ_
RS232
U2
_U2_
Serial TTL
SS
_SS_
AT wedge
UB
_UB_
USB-HID
SU
_SU_
USB-VCP
C01
_C01_
Bluetooth
SO
_SO_
IEEE 802.15.4
SM
_SM_
END
_ZZ_
U6
Page 12
OPTICON UNIVERSAL MENU BOOK
2. INTERFACE This chapter describes the configurable transmission options for your reader. Some options may not be relevant to the type of reader you have. An attempt to configure the reader for such options does not affect its operation and usually results in the reader producing an error tone, indicating you tried to make an illegal configuration entry.
2 Interface
U7
Page 13
OPTICON UNIVERSAL MENU BOOK
TxD: Transmitted Data: Transmits data from the reader to the host. This connection is mandatory.
2.1. RS232 options This paragraph describes the specific options for a reader with an RS232 interface. Bar code readers with an RS232 interface are normally supplied with either a DB25 or DB9 female connector. Both connectors are fitted with an external power connector. See figure 2.01 or 2.02.
RxD: Received Data: Receives data from the host to the reader. This connection is required if you want to send commands to the bar code reader or if software handshaking or acknowledgement control is used.
Fig. 2.01. RS232 options DB25
RTS: Request To Send: A general purpose output to the host, used for hardware flow control. This connection is optional.
1 2 3 4 5 7
1 2 3 4 5 7
FG TxD RxD RTS CTS SG
CTS: Clear To Send: A general purpose input to the bar code reader, used for hardware flow control. This connection is optional.
HOST
SCANNER
DB25S DB25P FG TxD RxD RTS CTS SG
SG: Signal Ground: Reference point for power supply and interface signals. This connection is mandatory.
Fig. 2.02. RS232 options DB9
3 2 5 7 8
3 2 5 7 8
TxD RxD SG RTS CTS
HOST
SCANNER
DB9S DB9P TxD RxD SG RTS CTS
Other connectors and/or connections are available by special order. Pin functions as seen from the bar code reader. FG: Frame Ground: This is normally connected to the "chassis ground" at the host computer. In the RS232 specification the use of FG is optional.
U8
Page 14
OPTICON UNIVERSAL MENU BOOK
2.1.1. Baud rate settings
The baud rate is the rate at which bits are transmitted from the reader to the host, and vice versa. Both the reader and the host should be set to the same baud rate
_ZZ_
150 baud
K0
_K0_
300 baud
K1
_K1_
600 baud
K2
_K2_
1200 baud
K3
_K3_
2400 baud
K4
_K4_
4800 baud
K5
_K5_
9600 baud
K6
_K6_
19200 baud
K7
_K7_
38400 baud
K8
_K8_
57600 baud
K9
_K9_
115200 baud
SZ
_SZ_
END
_ZZ_
U9
2 Interface
SET
Page 15
OPTICON UNIVERSAL MENU BOOK
2.1.2. Data, parity and stop bits The data characters may be transferred in one of the following formats:
Fig. 2.03. Data, parity, stop bits
A parity bit may be added to every character so that the total number of 1's in the data bits, together with the parity bit, is odd for odd parity or even for even parity. See figure 2.03.
(1)
START
7 Bit Data
(2)
START
7 Bit Data
START
7 Bit Data
PARITY
START
7 Bit Data
PARITY
START
8 Bit Data
START
8 Bit Data
START
8 Bit Data
PARITY
START
8 Bit Data
PARITY
(3) (4) (5) (6) (7)
STOP 2 STOP STOP 2 STOP STOP 2 STOP STOP
(8)
SET
_ZZ_
7 data bits
L0
_L0_
8 data bits
L1
_L1_
No parity
L2
_L2_
Even parity
L3
_L3_
Odd parity
L4
_L4_
1 stop bit
L5
_L5_
2 stop bits
L6
_L6_
END
_ZZ_
U10
2 STOP
Page 16
OPTICON UNIVERSAL MENU BOOK
ON the reader is allowed to transmit data. When all data has been transmitted, the reader will turn RTS OFF. In response, the host should turn OFF the reader's CTS. If, while RTS is ON, the CTS line is not ON for a certain configurable period, the reader will terminate the transmission with an error indication of the buzzer. See figure 2.05.
2.1.3. Handshaking
1. No handshake: Does not employ any handshaking: data is transmitted regardless of the control signals. This option will undo any handshake and flow control options selected.
RTS
ON
TxD
OFF
4. XON/XOFF: The reader sends data until an XOFF (ASCII DC3, Hex 13) character is received from the host. Only when the reader receives an XON (ASCII DC1, Hex 11) character, the reader continues to send its data. 5. ACK/NAK: After data has been transmitted, the reader expects to receive one of the following responses from the host:
ON
Response: "ACK" (ASCII: Hex Ø6) Action: The reader completes transmission with the good-read buzzer.
OFF ON OFF
Response: "NAK" (ASCII: Hex 15) Action: The reader sends the data again.
ON
TxD
ON OFF
Fig. 2.04. HandShaking Busy/ready
CTS
ON OFF
CTS
2. Busy/ready: The reader's RTS is ON as soon as the power is supplied to the reader and will stay ON while the reader can receive data from the host. The host will keep the reader's CTS ON while it is ready to receive data from the reader. While CTS is ON the reader is able to transmit data. The reader will abort transmission with an error indication of the buzzer when the CTS is not ON within a certain configurable period. The reader may drop RTS to OFF during transmission if it can not receive data simultaneously. See figure 2.04.
RTS
2
Fig. 2.05. HandShaking Modem mode
OFF
Response: "DC1" (ASCII: Hex 11) Action: The reader completes transmission without a good-read or error buzzer.
3. Modem mode: The reader's RTS is OFF as soon as power is supplied to the reader. The reader will turn RTS ON when it wants to transmit data to the host. The host should respond by putting CTS ON when it is ready to receive data. While CTS is
Response: "None" Action: If there is no response within one second then the reader terminates transmission with an error buzzer. See figure 2.06. U11
Interface
Data flow control is available using either hardware (Modem, Busy/Ready) or software (XON/XOFF). In addition, an optional acknowledgement control is available (ACK/ NAK with or without error response). Flow control may be combined with acknowledgement control. The RS232 voltage levels employed by most readers for transmission are either -10V (OFF) or +10V (ON).
Page 17
OPTICON UNIVERSAL MENU BOOK
Fig. 2.06. HandShaking ACK/NAK
Fig. 2.07. HandShaking ACK/NAK no response
Start of transmission
Start of transmission
Transmit data
Transmit data
Start 1 sec. timer
Answer received
No
Start 1oo ms. timer
Yes Answer received
No
Answer = NAK
Timer ended
No
Yes No
No
Answer = NAK
Timer ended
No
Yes
Yes
Answer = ACK
Yes
Yes
Answer = ACK
Yes
Yes
No No Answer = DC1
Yes Answer = DC1
Yes
No No ERROR Buzzer
ERROR Buzzer
GOOD READ Buzzer
ERROR Buzzer
GOOD READ Buzzer
END END
6. ACK/NAK no response: The difference from the ACK/NAK mode is that when no response from the host is received within 100 ms, the reader assumes that the data has been received correctly by the host. Response: "ACK" (ASCII: Hex Ø6) Action: The reader completes transmission with the good-read buzzer. Response: "NAK" (ASCII: Hex 15) Action: The reader sends the data again. Response: "DC1" (ASCII: Hex 11) Action: The reader completes transmission without a good-read or error buzzer. Response: "None" Action: If there is no response within 100 ms then the reader terminates transmission with a good read buzzer. See figure 2.07. U12
GOOD READ Buzzer
Page 18
OPTICON UNIVERSAL MENU BOOK
2.1.3. Handshaking
_ZZ_
No handshake
P0
_P0_
Busy/ready
P1
_P1_
Modem
P2
_P2_
XON/XOFF
ZG
_ZG_
ACK/NAK
P3
_P3_
ACK/NAK NO RESPONSE
P4
_P4_
Flow Control time out indefinitely
I0
_I0_
Flow Control time out 100ms
I1
_I1_
Flow Control time out 200ms
I2
_I2_
Flow Control time out 400ms
I3
_I3_
END
_ZZ_
U13
2 Interface
SET
Page 19
OPTICON UNIVERSAL MENU BOOK
2.1.4. Intercharacter delay for RS232 The intercharacter delay introduces a configurable time delay after each character transmitted. This may be used if the connected computer or terminal does not support flow control and is not capable of handling the received data.
SET
_ZZ_
No delay
KA
_KA_
20 ms delay
KB
_KB_
50 ms delay
KC
_KC_
100 ms delay
KD
_KD_
END
_ZZ_
U14
Page 20
OPTICON UNIVERSAL MENU BOOK
With keyboard: Use this mode in case a keyboard is connected to the PC wedge Y-cable. The wedge is only listening in case the computer is booting or when the wedge is idle.
2.2. Keyboard wedge/USB options This paragraph describes the options which are relevant to readers with a wedge or USB interface. The following parameters can be configured: • keyboard language • special options • intercharacter delay Because these options are interdependent, it is important to perform the configuration in the sequence given. Please consult your sales office for keyboard layouts and language currently supported. Keyboard wedge operation modes: This mode enables or disables responses from PC wedge to the computer during booting. In normal cases, the keyboard handles the responses to the computer. The PC wedge is only listening in order to be aware of the keyboard state.
The wedge is responding to all commands from the computer. The ‘without keyboard’ option is only supported for PC/AT wedges.
SET
_ZZ_
With keyboard
KM
_KM_
Without keyboard
KL
_KL_
END
_ZZ_
U15
2 Interface
Without keyboard: Use this mode in case no keyboard is connected to the PC wedge Y-cable. In some cases this mode is required in case only a PC USB keyboard is connected. If this option is enable, the computer can detect the wedge as a keyboard. In case the computer reports a keyboard error or in case no data is displayed, try this option. It is required to power OFF the PC, wait 10 seconds and power ON the PC again. Do not enable this option in case a keyboard is connected to the Y-cable.