Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 15

Opticon Universal Menu Book: bar code configuration and commands manual, pages 1 to 10

Pages 1 to 10 of 147

The original document is the PDF (593 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Opticon LG-K1WE5SP, Opticon 25-WEDGE-06 and Opticon HLT-1120 ELT-1120

Page 1 read from a scan by OCR; it may hold reading errors

Set up your personal configuration

Universal menu book bar code configuration and commands manual

Of TicCcoanNn ee

Page 2

OPTICON UNIVERSAL MENU BOOK

Set up your personal configuration

Universal menu book bar code configuration and commands manual ver. 11 © September 2007 Ui

Page 3

OPTICON UNIVERSAL MENU BOOK

CAUTION: This information is subject to change without prior notice.

LIMITED WARRANTY AND DISCLAIMERS

Copyright 2006, Opticon Sensors Europe B.V. All rights reserved.

Under all circumstances this manual should be read attentively, before installing and or using the product.

This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon Sensors Europe.

Serial number A serial number appears on all Opticon products. This official registration number is strictly related to the device purchased. Make sure that the serial number appearing on your Opticon device has not been removed. Removing the serial number might affect the warranty conditions and liability disadvantageously, so please be strict at maintaining the label with serial number on the Opticon product. Warranty / Warranty period / Liability Unless otherwise agreed in a contract, all Opticon products are warranted for the period of two years after purchase, covering defects in material and workmanship. Opticon will repair or, at its opinion, replace products that prove to be defective in material or workmanship under proper use during the warranty period. Opticon will not be liable in cases where modifications are made by the customer. In such case the standard repair charge will be applicable. The standard charge for repair will also be applicable in cases where no defect is found at all. These rules also apply for products that are still under warranty. Under no circumstance will Opticon Sensors Europe, be liable for any direct, indirect, consequential or incidental damages arising out of use or inability to use both the hardware and software, even if Opticon has been informed about the possibility of such damages. Packaging The packing materials are not harmful for the environment. We recommend that you save all packing material, as it should be used whenever you need to transport your scanner (eg. for service). Damage caused by improper repacking is not covered by the warranty. Trademark Trademarks used are property of their respective owners.

Uii

Page 4

OPTICON UNIVERSAL MENU BOOK

0.

Introduction .............................................U1

1.

Defaults ....................................................U5

2.

Interface ...................................................U7

2.1. RS232 options ..................................... U8 2.1.1. Baud rate settings................................ U9 2.1.2. Data, parity, stop bits ......................... U10 2.1.3. Handshaking...................................... U11 2.1.4. Intercharacter delay for RS232 .......... U14

4.1.

Case conversion .................................U82

4.3.1. Direct input keyboard keys .................U94 4.3.2. Direct input character misc. ................U97 4.3.3. Direct input numeric..........................U100 4.3.4. Direct input character .......................U101 4.3.5. Direct input lower case character .....U103 4.3.6. Direct input control character............U105 4.3.7. Direct input code id/length ................U108

2.3. Wireless options ................................ U20 2.3.1. Bluetooth address.............................. U21 2.3.2. Bluetooth security .............................. U23 2.3.3. Trigger connection options................. U24 2.3.4. Trigger disconnect options................. U26 2.3.5. Auto disconnect options..................... U27 2.3.6. Auto reconnect options ...................... U28 2.3.7. Wireless power saving ....................... U29 2.3.8. Memorizing ........................................ U30

5.

Read options ....................................... U109

5.1. Read mode options ..........................U110 5.1.1. Multiple read reset time ....................U112 5.1.2. Quiet zone options............................U113 5.1.3. Auto trigger options ..........................U114

Code options .........................................U33

3.1. Setting of readable codes .................. U34 3.1.1. Enabling a single read. Code............. U34 3.1.2. Enabling of readable codes ............... U38 3.2.

String options........................................ U81

4.2. Set prefix and suffix ............................U83 4.2.1 Set prefix ............................................U88 4.2.2. Set suffix.............................................U91

2.2. Keyboard wedge/USB options ........... U15 2.2.1. Keyboard layout ................................. U16 2.2.2. Special options .................................. U18 2.2.3. Intercharacter delay for wedges/USB ...................................... U19

3.

4.

Setting of number of characters......... U42

3.3. Setting code specific options ............. U46 3.3.1. Options for UPC-A ............................. U47 3.3.2. Options for UPC-E ............................. U48 3.3.3. Options for EAN-13 and EAN-8 ......... U50 3.3.4. Options for Code 39 and It.Pharm. .... U52 3.3.5. Options for Codabar .......................... U55 3.3.6. Options for 2of5 and S-Code ............. U59 3.3.7. Options for IATA ................................. U61 3.3.8. Options for MSI/Plessey .................... U62 3.3.9. Options for Telepen............................ U64 3.3.10. Options for UK/Plessey...................... U65 3.3.11. Options for Code 128 and EAN-128 .. U66 3.3.12. Options for Code 93........................... U68 3.3.13. Options for Code 11........................... U70 3.3.14. Options for Korean Postal Authority... U71 3.3.15. Options for RSS................................. U72 3.3.16. Options for Composite Codes............ U73

5.2. 5.3. 5.4. 5.5. 5.6.

Read time options.............................U114 Power control....................................U116 Redundancy .....................................U118 Positive and negative bar codes .......U119 Resolution and density .....................U120

6.

Indicator options................................. U123

6.1.

Buzzer settings .................................U124

6.2.

Good read LED.................................U126

7.

Miscellaneous ..................................... U127

7.1.

Diagnostics .......................................U127

7.2.

Serial configuration support..............U128 Appendix.............................................. U131

Uiii

A.

Trouble shooting ...............................U131

B.

Glossary of terms .............................U132

C.

Example codes .................................U136

Table of contents

3.3.17. Options for DataMatrix........................U75 3.3.18. Options for Aztec ................................U76 3.3.19. Options for QR Code ..........................U76 3.3.20. Options for Micro QR Code ................U77 3.3.21. Options for Maxicode..........................U78 3.3.22. Options for PDF417............................U78 3.3.23. Options for MicroPDF417 ...................U79

TABLE OF CONTENTS

Page 5

OPTICON UNIVERSAL MENU BOOK

Uiv

Page 6

OPTICON UNIVERSAL MENU BOOK

INTRODUCTION This menu book is intended for setting up your bar code reader to optimize its performance for your particular application. When the required options have been configured, they remain in the reader, even after power down. The reader can be returned to factory default by reading the default label.

0 Introduction

Menu labels The reader must be set by reading the bar code labels in the menu table. The layout of the table is explained in next figure 0.01.

Fig. 0.01. Menu labels optional setting factory default setting

Enter mode

Save mode serial commands configuration parameters

Besides options, some chapters have commands. The commands need to be scanned directly, without reading the “SET” and “END” labels. The commands are executed directly and, unlike options, are not stored in non volatile memory.

U1

Page 7

OPTICON UNIVERSAL MENU BOOK

• 6: Use chapter 6 to select the indicator options you prefer. These options affect the operation of the buzzer and good read LED. * The reader will now operate to your personal preference.

Configuring via the menu book To configure the required options proceed as follows: • scan the SET label • scan the required option(s) • scan the END label After scanning the END label, the new settings are stored in non volatile memory.

See figure 0.02.

Recommended steps to follow for quick configuration After checking your connection you are ready to start the configuration of your reader.

Fig. 0.02. Configuring via the menu book

• Check connection: Ensure that the power is disconnected from your equipment before you connect the reader. After connecting the data cable, the power can be applied to the equipment and the reader.

Power OFF Connect reader

• 1: Use chapter 1 to set the correct default for your reader. * The reader is now in factory default.

Power ON Set Default

• 2: Use chapter 2 to optimize the interface. * The reader is now able to read bar codes and transmit the data.

Optimize interface Optimize symbologies

• 3: Use chapter 3 to optimize the reader for the type of bar codes you use. Set the readable codes first and then the options for each of these codes. * The reader is now able to read the codes you selected, validate the data using length and check digit and transmit that part of the data you specified.

Set string options Set read options Set indicator options

• 4: Use chapter 4 to select the string options for your application. These include transmission of code length, conversion of upper and lower case and setting a prefix and suffix. * The reader can now read and transmit the data in the required format. • 5: Use chapter 5 to select the read options to your preference. These options affect the read mode, read time, trigger and redundancy.

U2

Page 8

OPTICON UNIVERSAL MENU BOOK

The characters transmitted must be separated by an intercharacter delay to allow the reader to process each character received and to execute the command string. Configuring via OptiConfigure OptiConfigure is the interactive Universal menu book version. With OptiConfigure it is possible to create your own personal setup sheet online. OptiConfigure supports Opticon bar code readers which can be configured with this Universal menu book. In addition OptiConfigure offers product specific and less often used menu labels. Based on the product and software version selected, OptiConfigure will show these specific options.

• transmit <ESC><Command string 1><CR> • transmit <ESC><Command string 2><CR> • transmit <ESC><Command string n><CR> • transmit <ESC>Z2<CR> <ESC> <ESC> is the ASCII escape character (Hex 1B). <Command string> <Command string> is the ASCII command with its parameters as would be scanned from the menu book, i.e. <ESC>M41B<CR> configures the ASCII control code <STX> as the prefix for Code 39. Example in hexadecimal format: 1B 4D 34 31 4B ØD Each 3-character command should be preceded with the '[' character (Hex 5B) i.e. <Esc>[BCC<CR> is used to enable Data Matrix. Each 4-character command should be preceded with the ']' character (Hex 5D) i.e. <Esc>]DIAU<CR> is used to disable auto connect.

OptiConfigure can be accessed via the Opticon home page (www.opticon.com). From there select the OptiConfigure button.

Fig. 0.03. Opticonfigure

Set up your personal configuration

Universal menu book on-line bar code configuration and commands application

<CR> <CR> is the ASCII CR character (Hex ØD). Z2 Some options are not immediately active, like baud rate settings. Most other options are immediately active, but the command Z2 must be send to store the settings to non volatile memory. The following commands may be used to: Command B sound a good read beep Command E sound an error beep Command L switch on good read LED Command N switch on bad read LED Command O switch on both LEDs Command Y de-trigger the reader Command Z trigger the reader Command P disable the laser Command Q enable the laser U3

0 Introduction

Configuring via RS232 In the middle column of the menu pages the command is printed, e.g. U2. These commands can be sent to readers with an RS232 interface. To configure via the RS232 port proceed as follows:

Page 9

OPTICON UNIVERSAL MENU BOOK

U4

Page 10

OPTICON UNIVERSAL MENU BOOK

1. DEFAULTS This option allows you to undo all previously configured options and bring the reader's configuration back to factory default settings. These factory default settings are printed in bold.

1 Defaults

Note that differences may occur depending on the type of interface as will be mentioned in the text. Select only the correct default settings corresponding to your hardware "defaults" label. The interfaces supported depend on the reader model and software release. Please consult your sales office for not listed interfaces.

U5