Page 17

2.4 DIP SWITCH SETTINGS Open the cover of the DIP switches on the bottom of the cradle in order to reach the DIP switches. • Turn the DIP switch ON by moving it upwards. • Turn the DIP switch OFF by moving it downwards. Single cradle DIP switch settings:

* Set baud rate as in table below. ** In typical use keep cascade switch SW5 off. User baud rate settings: *) Baud rate

SW 1

SW 2

SW 3

2400

ON

OFF

OFF

DIP Switch

ON

SW 1

Baud rate *

Baud rate *

4800

OFF

ON

OFF

SW 2

Baud rate *

Baud rate *

9600 (default)

ON

ON

OFF

SW 3

Baud rate *

Baud rate *

19200

OFF

OFF

ON

SW 4

Spare

38400

ON

OFF

ON

SW 5

Spare

57600

OFF

ON

ON

SW 1, 2, 3 determines baud rate.

115200

ON

ON

ON

SW 6

Auto-baud rate (PCcontrolled)

OFF

Multicradle DIP switch settings: DIP Switch

ON

OFF

SW 1

Baud rate *

Baud rate *

SW 2

Baud rate *

Baud rate *

SW 3

Baud rate *

Baud rate *

SW 4

RS232/ RS485

RS232 only

SW 5

Cascade **

SW 6

RS485 termination ON

RS485 Termination OFF

SW 7

Factory setting

SW 8

Factory setting OPL972X/CRD972X OPTICON - 17

Page 18

2.5 BLUETOOTH INSTALLATION In the bar code collector with Bluetooth interface some settings can be made in the system menu. Get system menu

Press all 3 keys at the same time to get the system menu. To navigate downwards use the right key [Q2] and to navigate upwards use the left key [Q1]. Confirm or select with the middle [Trigger]key.

Cancel operation

When an operation needs to be cancelled, press all 3 keys at the same time to cancel the current option and get the system menu.

2.5.1 SET OR SEARCH BLUETOOTH DEVICE ADDRESS: To enable the bar code data collector with Bluetooth interface to communicate to another Bluetooth device, the Bluetooth address of the device needs to be set in the system menu of the bar code data collector. Start the system menu Select option Input address. Set Bluetooth address To set by manual entry, select Manual. To search for Bluetooth device address, select Discovery.

Manual entry The address shown is either 000000000000, or the address that was entered before. The Bluetooth address can be found on the other device. Mostly it is displayed on the product label as a 12 digits number or a number with 6 hex digit pairs. (e.g. 0050f27d78c5). The digits can be selected one by one by the block marker. Change the digit by pressing the left key [Q1]. Every time the left key [Q1] is pressed the value of the digit is incremented by one hexadecimal value. When the proper value is displayed move the marker to the next digit with the right key [Q2]. When the setting of the device address is done, confirm with the middle [Trigger]key.

18 - OPTICON OPL972X/CRD972X

Page 19

Discovery The discovery method is a more automated method. The bar code data collector will try to discover all Bluetooth devices in range (up to a maximum of 10 devices). The address and the name of each Bluetooth device is shown one by one in the display. Navigate downwards by the right key [Q2] and navigate upwards by the left key [Q1]. When device that should be used for communication is found, select it by the middle [Trigger]key.

2.5.2 SECURITY To provide additional security connections, the Bluetooth specification allows you to enable a special security setting, so that a PIN-code is required from the barcode data collector in order to establish a connection. If you want to use 'unsecured' connections, do not set the PIN-code. Start the system menu. Select option Input PIN-code. Select option Input PIN-code. Set PIN-code The code shown is either ……………., or the code that was entered before. The PIN-code is a code of 1 to 16 digits. Any personal combination of numeric values can be set. The digits of the address can be selected one by one by the block marker. Change the digit by pressing the left key [Q1]. Every time the left key [Q1] is pressed the value of the digit is going up with one numeric value. When the proper value is displayed move the marker to the next digit with the right key [Q2]. When the setting of the code is done, confirm by the middle [Trigger]key. Delete PIN-code The PIN-code is seen as not set when all digits are set to none (…………….)

OPL972X/CRD972X OPTICON - 19

Page 20

2.6 COMMUNICATION 2.6.1 RS32 INTERFACE Check if the chosen COM port matches the COM port in the user’s application program. Check if the baud rate of the cradle and the host computer match.

2.6.2 USB INTERFACE Check if the defined COM port in Windows matches the COM port in the user’s application program. Check if the baud rate of the cradle and the host computer match.

2.6.3 MULTICRADLE SINGLE COMMUNICATION When using the multicradle type with single communication, note that the model has only one slot that supports communication. To transmit data to the host, place the bar code data collector in the right slot of the cradle seen from the front side.

2.6.4 BLUETOOTH BAR CODE DATA COLLECTOR The Bluetooth bar code data collector model will communicate with the SIG certified Bluetooth devices. The choice in profile (SPP or DUN) that needs to be supported must be set in the user’s application program.

20 - OPTICON OPL972X/CRD972X

Page 21

3 READING BAR CODES TAKE CARE OF THE 'HANDLING INSTRUCTIONS' AND 'GET STARTED' PRECAUTIONS.

3

Instructions Point the bar code data collector to the bar code and press the trigger key. Fit the bar code in the laser beam from margin to margin and pass the scanner to the bar code, as shown in the scan position illustration. The bar code will be read and the reading results will be indicated. A "Good Read" means that the scanner has effectively recognised and decoded the bar code. In most cases, the application program will provide an indicator signal or a buzzer signal to indicate a good read to the user. The bar code data collector is a Class I laser product conforming to the strictest laser safety standards. However, we recommend that you avoid looking directly into the laser beam emitter, or pointing the laser beam directly into someone's eyes.

X

X

Barcode reading problems When the barcode can not be read, try the following: • Check that the width of the bar code label does not exceed the width of the light beam. • Change the angle between the bar code and the scanner. • Change the distance between the bar code and the scanner.

X X X

X OPL972X/CRD972X OPTICON - 21

Page 22

4 TROUBLE SHOOTING

4

This chapter contains information on solving problems you may encounter when using the barcode data collector and/or cradle. If problems occur, first carry out some general checks, before verifying the problem with the descriptions in this chapter. General checks: • Make sure the product is installed properly. • Check the power supply of all devices • Is the reading window of the product clean? • Are the bar code labels damaged? • Check if the error also occurs with other bar code labels. Product does not operate: • Check if the battery requires charging. If you can not solve the problem: If the equipment still does not work after these checks have been performed, please verify if one of the problems described in this chapter applies to the problem you have with the scanner.

4.1 COMMUNICATION MALFUNCTIONING No communication from the cradle to the device, or data is corrupted. ? Power indicator of the cradle is not red. • Check the connection of the power supply to the cradle. • Check if the mains socket has power. ? No data transmitted, or corrupted data. • Check if the interface cable is undamaged, and properly connected to the cradle and the host computer. • Check the COM port and baud rate settings, and try again.

22 - OPTICON OPL972X/CRD972X

Page 23

4.2 READ OPERATION MALFUNCTIONING

Laser stays off, when pressing the trigger key.

When the barcode data collector has a problem with reading the label:

? Trigger key has no scan function. • If your bar code data collector has a display, check in your display if the scan menu is selected. When an other menu is selected switch to the scan menu.

? General tips. • Change the angle of the bar code data collector relative to the bar code. • Change the distance between the bar code and the bar code data collector. ? The label consists of small bars with small spaces (high-resolution label). • Decrease the distance between the bar code and the bar code data collector. ? The bar code is larger than the laser beam. • Try moving the bar code data collector a bit further away from the bar code. ? The reading window is dirty. • Clean the reading window of the bar code data collector. ? The type of the bar code label is not enabled. • If applicable, enable the bar code symbology in the application program. ? The error occurs consistently with a certain batch of labels. • Verify the barcode. If you use a barcode printer it is advised to use also a barcode verifier. 4.3 BARCODE DATA COLLECTOR MALFUNCTIONING Barcode data collector does not respond to key presses, while the display stays on.

? Laser temperature has become too high. • The laser is switched off automatically, when the laser temperature becomes above 50°C. Wait until the temperature has dropped. Barcode data collector does not work, when pressing the trigger key. ? The battery is empty. • Charge the barcode data collector in the cradle. Bar code data collector can be used only for a short time after recharging. ? The main battery is not properly charged. • Check if the charging contacts of the bar code data collector and the cradle are clean. If needed, clean the charging contacts. • Check the cradle for power by checking the power supply and/or the mains socket. • Check if the bar code data collector is properly placed on the cradle.

When the product needs to be repaired: The label with serial number should be present. If returning the product, please use the original packaging to minimise the chance of damage.

? Message “Application halted” or “No application installed” is shown. • There is no proper user’s application loaded in the bar code data collector. Contact your supplier.

OPL972X/CRD972X OPTICON - 23