Page 9
2 2 GET STARTED Fix hand strap to bar code data collector. Use the hand strap properly to avoid drop. Read instructions in this manual.
D. Cleaning instructions Clean the reading window periodically with a soft dry cloth. Clean the exterior by wiping it with a soft, dry cloth. Do not use thinner, white spirit or other solvents. These can discolour the case and the keys and has a negative effect on the lifetime of the keys. Clean the electrical contacts of the bar code data collector and the cradle with a soft dry cloth, or cotton bud. Avoid touching the contacts The contacts must stay as clean as possible to maintain optimal charging capacity. Do not use water when cleaning the cradle. This can cause malfunction.
Insert battery. To be sure of proper operation, it is advised to start with a fully charged battery. First charge the bar code data collector for 8 hours. Read instructions in this manual. Place the cradle in normal office conditions. Avoid a place under strong light. Otherwise infra red communication may be disturbed. Read instructions in this manual. Use properly. Take notice that the CRD972X cradle is designed for the OPL972X bar code data collector.
E. Maintenance There are no user-serviceable parts inside the bar code data collector or the cradle. So do not try to take it apart. The manufacturer will not be liable for any damage caused by the customer. In case of serious malfunction, please consult your supplier.
OPL972X/CRD972X OPTICON - 9
Page 10
2.2 BATTERY INSTRUCTIONS
1
FOLLOW THE INSTRUCTIONS FOR INSTALLING, CHARGING AND REMOVING THE BATTERIES VERY STRICTLY.
2
WRONG USE OF BATTERIES MIGHT CAUSE SERIOUS DAMAGE TO THE BAR CODE DATA COLLECTOR OR TO THE CRADLE. THE PRODUCTS ARE NOT WARRANTED FOR DAMAGE, DEFECTS, MALFUNCTION OR LOSS OF DATA, RESULTING FROM INCORRECT USE OF BATTERIES.
3
4
2.1 FIX HAND STRAP Instructions 1. Fix the small thin cord of the strap around the pillar of the bar code data collector. (ref. 1) 2. Insert the handle cord of the strap into the thin loop in order to fix the hand strap. (ref. 2) TO AVOID DROP HOLD THE HAND STRAP AROUND THE WRIST WHEN CARRYING THE BAR CODE DATA COLLECTOR. (REF. 3) DO NOT SWING THE BAR CODE DATA COLLECTOR AROUND. (REF. 4)
10 - OPTICON OPL972X/CRD972X
Never remove the battery while the bar code data collector is turned on. Doing so can cause data in the bar code data collector to be deleted. If you have data stored, make sure the data is transmitted to the host system. Use proper battery Only use the Opticon rechargeable battery as specified from Opticon. Insert the battery correctly. The bar code data collector may be damaged by wrong insertion. Handle properly and do not force. Use the cradle to charge battery The battery of Opticon can only be charged inside the bar code data collector. 2.2.1 HOW TO CHARGE THE BATTERY If the bar code data collector with the battery is placed in the cradle, the voltage and the required charging time will be automatically determined and the cradle will charge for a maximum of 8 hours. The charging procedure is fully automated.
Page 11
2
3
1
4 5
2.2.2 HOW TO (RE)PLACE THE BATTERY Unlock battery case cover: (ref. 1 and 2) • Unlatch the case cover by lifting first into the direction of the nose and then lift up the case. Install Opticon battery: (ref. 3.) • Remove old battery. Insert new battery as instructed on the battery. Do not use force. Lock battery case cover: (ref. 4 and 5) • Position the case cover into the savings and latch it by pressing slightly.
OPL972X/CRD972X OPTICON - 11
Page 12
2.3 INSTALLATION INSTRUCTIONS EXERCISE CAUTION AT ALL TIMES WHEN WORKING WITH AC-POWERED EQUIPMENT. TURN OFF YOUR DEVICES BEFORE INSTALLATION. BECAUSE OF THE SPECIAL PIN-OUT OF THE CONNECTORS, USE THE CABLES SUPPLIED BY THE MANUFACTURER. When you need another cable for a certain device, that is not supplied, contact your supplier to purchase the right cable.
2.3.1 CONNECT CHARGING CRADLE Start Switch off the power of the host computer. (ref. 1.) Choose proper place Place the cradle in normal office conditions, avoid a place under strong light. (ref. 2.) Connect power Connect the power supply. End Switch on the power of the host computer. Place the bar code data collector in the cradle. LED indicator Typical LED indication: red: power is on
1 2 12 - OPTICON OPL972X/CRD972X
Page 13
2.3.2 CONNECT RS232 CRADLE Start Switch off the power of the host computer. (ref. 1.) Choose proper place Place the cradle in normal office conditions, avoid a place under strong light. (ref. 2.) Set DIP switch Set the required DIP switches for baud rate. For (default) settings notice DIP switch table in the next chapter. (ref 3.) Connect interface cable Connect the cable between the cradle and the host computer.
1 2 ON
1
2
3
4
5
6
(ref. 4.) Connect power Connect the power supply. End Switch on the power of the host computer. Place the bar code data collector in the cradle.
3
LED indicator Typical LED indications are: red: power is on flashing green: collector sends to host flashing yellow: host sends to collector FOR CONNECTING A NETWORK OF CRADLES SEE RS485 DESCRIPTION.
4
OPL972X/CRD972X OPTICON - 13
Page 14
2.3.3 CONNECT RS232 MULTICRADLE Start Switch off the power of the host computer. (ref. 1.) Choose proper place Place the multicradle in normal office conditions, avoid a place under strong light.
1
(ref. 2.) Set DIP switch Set the required DIP switches for baud rate. For (default) settings notice DIP switch table in the next chapter.
2 6 ON
FOR CONNECTING A NETWORK OF MULTICRADLES SEE RS485 DESCRIPTION.
14 - OPTICON OPL972X/CRD972X
4
5
LED indicator Typical LED indications are: red: power is on flashing green: collector sends to host flashing yellow: host sends to collector
4
3
3
End Switch on the power of the host computer. Place the bar code data collector(s) in the multicradle.
2
(ref. 4.) Connect power Connect the power supply.
1
(ref 3.) Connect interface cable Connect the cable between the multicradle and the host computer. For RS232 interface use the left RS232 connector (RS232C-1).
Page 15
2.3.4 CONNECT USB TO WINDOWS PC Get USB driver • Download the USB driver from the software download section on the Opticon website. (The USB driver can be found as software for either CRD972X or OPL972X) • Place the file on your hard disk in a separate directory and unpack the contents of the file. Choose proper place Place the cradle in normal office conditions, avoid a place under strong light. Connect interface cable Connect the cable between the cradle and the host computer. Connect power Connect the power supply. Add New Hardware If the wizard for new hardware is not started automatically, go to ‘Control Panel’ – ‘Add Hardware’. • Select the option to search for the best driver for your device. Browse for the directory where you put the contents of the downloaded USB driver file. • Windows should recognize the USB cradle as ‘USB High Speed Serial Converter’ • Possibly (depending on Windows version) the system will ask for the ‘ftdiport.cat’ file. This can be skipped (‘Skip File’ button). • Finish the installing procedure. A message will pop-up that new hardware is found, recognized as USB Serial Port. • Possibly (depending on Windows version) the system asks to insert a disk labeled ‘FTDI USB Drivers Disk’, click on OK and in the next screen skip this action. • When the USB driver is installed, you can check on ‘Control Panel’ – (‘System’) – ‘System Properties’ (‘Hardware’) – ‘Device Manager’menu if the ‘USB High Speed Serial Converter’ is recognized. • Check at properties for the COMport: ‘USB Serial Port (COMn). This information might be needed for application loading.
Cradle installed Place the bar code data collector in the cradle LED indicator Typical LED indications are: red: power is on flashing green: collector sends to host flashing yellow: host sends to collector
OPL972X/CRD972X OPTICON - 15
Page 16
2.3.5 CONNECT RS485 MULTICRADLE NETWORK THIS PART DESCRIBES THE NETWORK DETAILS. FOR CONNECTION DETAILS REFER TO PREVIOUS PAGE. TAKE NOTICE OF THE NECESSARY PRECAUTIONS THAT NEEDS BE MADE TO ESTABLISH A PROPER NETWORK CONNECTION AS DESCRIBED BELOW. Connect RS232 Only 1 multicradle in the network will be connected to the PC through one RS232 cable. For RS232 interface use the left RS232 connector (RS232C1). Through this connection all multicradles can communicate to the PC.
Set DIP switch settings For (default) settings notice DIP switch table in the next chapter. • All multicradles in the network need to be set to RS232/RS485 connection. • All multicradles need to have the same baud rate to be set by DIP switch. • The first and the last multicradle in the network must have the termination resistors set. LED indicator Typical LED indications are: red: power is on flashing green: collector sends to host flashing yellow: host sends to collector
Connect RS485 A maximum of 16 multicradles can be connected in a network through RS485 cables.
3
4
5
6 ON
SLAVE RS232/RS485 TERMINATE
2
16 - OPTICON OPL972X/CRD972X
SLAVE RS232/RS485
1
MASTER RS232/RS485 TERMINATE