Programmable Controller SYSMAC CQM1H, pages 61 to 68

Pages 61 to 68 of 75: CQM1-SF200 Front Page; Ordering Information

The original document is the PDF (16 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Omron CQM1

Page 61

Dedicated I/O Units

Safety Relay Unit CQM1-SF200

Safety Relay Unit

CQM1-SF200 • Reduces wiring effort and installation space for safety circuits. • Monitors the following four statuses of the safety circuit 1. Safety Circuit Output Status Monitors if the safety circuit is operating and producing outputs. 2. Safety Circuit Power Status Monitors the status of the power supply to the safety circuit. 3. K1 Relay Operating Status 4. K2 Relay Operating Status Monitors the status of the internal relays that form the safety circuit. This helps troubleshooting safety circuit problems.

• General-purpose Inputs In addition to the safety circuit, a general-purpose input section (4 inputs and 1 common) is provide, which can be used for general controls.

Performance Specifications Item

Specifications

Contact resistance (See note 1.)

100 mΩ

Operating time (See note 2.)

300 ms max.

Response time (See notes 2 and 3.)

10 ms max.

Durability

Mechanical

5 million operations min. (switching frequency: 7,200 times/hour)

Electrical

100,000 operations min. (rated load, switching frequency: 1,800 times/hour)

Error rate (P level: reference value)

1 mA at 5 VDC

Weight

260 g max.

Note: 1. Measurement conditions: 1 A at 5 VDC voltage drop method 2. Bounce time is not included. 3. The response time is from when the input is turned OFF to when the main contact turns OFF.

Ratings (Safety Circuit) Power Supply Section Item Supply voltage

Switching Section Specifications

24 VDC

Permissible voltage fluctuation –15%/+10% of supply voltage range Power consumption

24 VDC: 1.7 W max.

Input Section Item Input current

64

Specifications 75 mA max.

Item

Specifications

Load

Resistive load (cos=φ1)

Rated load

5 A at 250 VAC

Rated switching current

5A

Page 62

Dedicated I/O Units

Safety Relay Unit CQM1-SF200

Ratings (General-purpose Input) Item

Specifications

Rated input voltage

24 VDC –15%/+10%

Input impedance

4.0 kΩ

Input current

6 mA typical (24 VDC)

ON voltage/ON current

14.4 VDC min./3 mA min.

OFF voltage/OFF current

5 VDC max./1 mA max.

ON/OFF response time

8 ms max. (selectable from 1 to 128 ms using System Setup.)

Number of circuits

4 inputs and 1 common

Number of points that turn ON 100% simultaneously ON simultaneously Internal current consumption

50 mA max.

Control Input Specifications

General-purpose Inputs

Safety circuits

Indicator

Indicator

Internal Circuits

Indicator

4.0 kΩ 0.01 µF

820 Ω

Input indicator

65

Page 63

Ordering Information

Ordering Information ■ International Standards The products shown in the attached tables are those that conform to the UL, CSA, cULus, cUL, NK, Lloyd’s Register, and EC Directives as of the end of September 2001. (U: UL, C: CSA, UC: cULus, CU: cUL, N: NK, L: Lloyd, CE: EC Directives) Please contact OMRON representative for application conditions.

■ EMC Directives Applicable Standards

Low Voltage Directive

EMI:EN50082-2 EMS:EN61131-2 and EN61000-6-2 (See note.) PLCs are electrical devices that are incorporated in machines and manufacturing installations. OMRON PLCs conform to the related EMC standards so that the devices and machines into which they are built can more easily conform to EMC standards. The actual PLCs have been checked for conformity to EMC standards. Whether these standards are satisfied for the actual system, however, must be checked by the customer. EMC-related performance will vary depending on the configuration, wiring, and other conditions of the equipment or control panel in which the PLC is installed. The customer must, therefore, perform final checks to confirm that the overall machine or device conforms to EMC standards.

Applicable Standard

66

EN61131-2 Devices that operate at voltages from 50 to 1,000 VAC or 75 to 150 VDC must satisfy the appropriate safety requirements. With PLCs, this applies to Power Supply Units and I/O Units that operate in these voltage ranges. These Units have been designed to conform to EN61131-2, which is the applicable standard for PLCs.

Page 64

Ordering Information

Power Supply Units

Power Supply Units Name

Specifications Rated voltage

AC Power Supply 100 to 240 V AC Units 50/60 Hz

Allowed voltage range 85 to 265 V AC

110/230 V AC 50/60 Hz DC Power Supply 24 V DC Units

Model

Output capacity

Service power supply

International standards

18 W

None

CQM1-PA203

U, C, N, L, CE

30 W

24 V DC 0.5 A

CQM1-PA206

U, C, L, N

80 to 138 V AC 160 to 276 V AC

30 W

24 V DC 0.5 A

CQM1-PA216

N, L, CE

20 to 28 V DC

30 W

---

CQM1-PD026

UC, N, L, CE

CPU Units (with 16 built-in DC input points) Specifications Memory capacity

I/O capacity

Program: 3.2 Kwords DM area: 3 Kwords

256 points

Program: 7.2 Kwords DM area: 6 Kwords

512 points

Built-in inputs 16 DC inputs

Model

Built-in RS232C port No

Support of Inner Boards

Support of Controller Link Unit

No

No

Yes

CQM1H-CPU11

International standards

U, C, N, L, CE

CQM1H-CPU21 Yes

Yes

Program: 15.2 Kwords DM area: 6 Kwords EM area: 6 Kwords

CQM1H-CPU51

UC, N, L, CE

CQM1H-CPU61

U, C, N, L, CE

Inner Boards Name

Specifications

Model

International standards

High-speed Counter Board

4 pulse inputs (high-speed counter) at 500 kHz max. 4 external outputs

CQM1H-CTB41

U, C, N, L, CE

Pulse I/O Board

2 pulse inputs, Single-phase: 50 kHz, Differential phase: 25 kHz 2 pulse outputs, 50 kHz max. Both fixed and variable duty factors are supported.

CQM1H-PLB21

U, C

Absolute Encoder Interface Board

2 absolute encoder (gray code binary) inputs (4 kHz)

CQM1H-ABB21

U, C, N, L

Analog Setting Board

4 analog settings

CQM1H-AVB41

U, C, N, L, CE

Analog I/O Board

4 analog inputs of 0 to 5 V, 0 to 20 mA, –10 to +10 V 2 analog outputs of 0 to 20 mA, –10 to +10 V

CQM1H-MAB42

CE

Serial Communications Board

One RS-232C port and one RS-422A/485 port

CQM1H-SCB41

U, C, N, L, CE

Model

International standards

Communications Units Name Controller Link Unit (Wired)

Specifications Data link (Maximum number of words per node: 8,000) Message communications (SEND/RECV/CMND instructions)

CQM1H-CLK21

U, C, CE

67

Page 65

Ordering Information

Memory Cassettes

Memory Cassettes Memory Flash memory

Memory capacity/Clock function 16 Kwords

EEPROM

CQM1H-ME16K with clock

CQM1H-ME16R with clock

CQM1-ME08R with clock

CQM1-ME04R

8 Kwords

CQM1-ME08K

4 Kwords EPROM Memory Cassette (Memory chip not included) EPROM chip

Model

International standards U, C, N, L, CE UC, N, L, CE

CQM1-ME04K

Cassette with IC socket only (EPROM chip sold separately) with clock

U, C, N, L, CE

CQM1-MP08K CQM1-MP08R

256 KB (16 Kwords), 150 ns, 27256 IC or equivalent, 12.5 V

ROM-JD-B

512 KB (32 Kwords), 150 ns, 27512 IC or equivalent, 12.5 V

ROM-KD-B

CE

Available Models Memory

Memory capacity/Clock function

Model

I/O Control Unit

Connects to right-hand side of CPU Block

CQM1H-IC101

I/O Interface Unit

Connects to left-hand side of Expansion I/O Block

CQM1H-II101

I/O Extension Cable

For connection with I/O Control Unit and I/O Interface Unit

Cable length: 0.3 m

CS1W-CN313

Cable length: 0.7 m

CS1W-CN713

International standards U, C, CE L, CE

I/O Units ■ Input Units Input type DC inputs

AC inputs

Specifications

Model

International standards

8 points, 12 to 24 V DC (independent commons, 1 point/common × 8 circuits)

CQM1-ID211

U, C, N, L, CE

16 points, 12 V DC (16 points/common × 1 circuit)

CQM1-ID111

U, C

16 points, 24 V DC (16 points/common × 1 circuit)

CQM1-ID212

UC, N, L, CE

32 points, 12 V DC (32 points/common)

CQM1-ID112

U, C

32 points, 24 V DC (32 points/common)

CQM1-ID213

U, C, N, L, CE

32 points, 24 V DC (32 points/common × 1 circuit)

CQM1-ID214

U, C, CE

8 points, 100 to 120 V AC (8 points/common)

CQM1-IA121

U, C, L, CE

8 points, 200 to 240 V AC (8 points/common)

CQM1-IA221

■ Output Units Output type Contact outputs Transistor outputs

AC outputs

Specifications

Model

8 points, 250 V AC (cosφ = 1.0/0.4)/24 V DC 2 A (16 A/Unit), independent commons

CQM1-OC221

16 points, 250 V AC (cosφ = 1.0/0.4)/24 V DC 2 A (8 A/Unit)

CQM1-OC222

UC, N, L

8 points, 250 V AC 2 A (cosφ = 1.0/0.4)/24 V DC 2 A, independent common

CQM1-OC224

CE

8 points, 24 V DC, 2A (5 A/Unit), 8 points/common

CQM1-OD211

U, C, N, L, CE

16 points, 50 mA at 4.5 V DC to 300 mA at 26.4 V DC, 16 points/common

CQM1-OD212

32 points, 16 mA at 4.5 V DC to 100 mA at 26.4 V DC

CQM1-OD213

16 points, 24 V DC, 300 mA, PNP outputs

CQM1-OD214

8 points, 24 V DC, 1.0 A, PNP outputs (4 A/Unit), short-circuit protection

CQM1-OD215

U, C, N, L

U, C, L, CE

32 points, 24 V DC, 0.5 A, PNP outputs (5 A/Unit), short-circuit protection

CQM1-OD216

CE

8 points, 0.4 A at 100 to 240 V AC, two circuits with 4 points/common each

CQM1-OA221

U, C, L

6 points, 0.4 A at 100 to 240 V AC, two circuits with 4 points/common and 2 points/com- CQM1-OA222 mon

68

International standards

CE

Page 66

Ordering Information

Dedicated I/O Units

Dedicated I/O Units Name CompoBus/S Master Unit

Specifications

Model

Number of I/O points per Master: 128 (64 inputs and 64 outputs) CQM1-SRM21-V1 Communications cycle time: 0.5 ms min.

International standards U, C, CE

DeviceNet I/O Link Unit

Number of I/O points: 16 inputs and 16 outputs

CQM1-DRT21

Analog Input Unit

Analog inputs: 4 points

CQM1-AD041

Analog Output Unit

Analog outputs: 2 points

CQM1-DA021

Power Supply Units

Required for Analog Input and Output For one Analog Unit Units. For two Analog Units

CQM1-IPS01

B7A Interface Unit

16 outputs

CQM1-B7A02

---

16 inputs

CQM1-B7A12

U, C

32 outputs

CQM1-B7A03

Temperature Control Units

U, C, N, CE

CQM1-IPS02

32 inputs

CQM1-B7A13

16 inputs and 16 outputs

CQM1-B7A21

---

Thermocouple input, transistor (NPN) output, 2 loops

CQM1-TC001

U, C

Thermocouple input, transistor (PNP) output, 2 loops

CQM1-TC002

Platinum resistance thermometer, transistor (NPN) output, 2 loops

CQM1-TC101

Platinum resistance thermometer, transistor (PNP) output, 2 loops CQM1-TC102

Safety Relay Unit

Thermocouple input, transistor (NPN) output, 4 loops

CQM1-TC201

U, C, CE

Thermocouple input, transistor (PNP) output, 4 loops

CQM1-TC202

U, C, CE

Platinum resistance thermometer, transistor (NPN) output, 2 loops (with heater burnout alarm)

CQM1-TC203

U, C, CE

Platinum resistance thermometer, transistor (PNP) output, 2 loops CQM1-TC204 (with heater burnout alarm)

U, C, CE

Thermocouple input, transistor (NPN) output, 4 loops

CQM1-TC301

U, C, CE

Thermocouple input, transistor (PNP) output, 4 loops

CQM1-TC302

U, C, CE

Platinum resistance thermometer, transistor (NPN) output, 2 loops (with heater burnout alarm)

CQM1-TC303

U, C, CE

Platinum resistance thermometer, transistor (PNP) output, 2 loops CQM1-TC304 (with heater burnout alarm)

U, C, CE

Emergency stop unit: 2 inputs/2 outputs, 4 general-purpose inputs CQM1-SF200

U C, CE

DIN Track Name Mounting Tracks

Specifications Track length: 50 cm

Height: 7.3 mm

Track length: 1 m Track length: 1 m End Plate

Model PFP-50N

International standards L

PFP-100N Height: 16 mm

PFP-100N2

Fasten mounting brackets on both sides of the PLC to prevent it PFP-M from sliding left or right. Two End Plates are provided with the CPU Unit.

Note: DIN Track products must be ordered in lots of ten.

69

Page 67

Ordering Information

Programming Devices and Accessories

Programming Devices and Accessories ■ Programming Consoles Name

Specifications

Programming Consoles

Connecting Cables Peripheral Port Conversion Cable

Model

International standards

2-m Connecting Cable included (No other Connecting Cables re- CQM1H-PRO01-E quired.)

U, C, CE

2-m Connecting Cable included (compatible with C-series PLCs) CQM1-PRO01-E The CS1W-CN114 peripheral port conversion cable must be purchased separately (see below).

U, C, N, CE

C200H-PRO27-E Requires a separate Connecting Cable. The C200H-CN222 conecting cable, C200HS-CN222 connecting cable, or CS1W-CN114 peripheral port conversion cable must be purchased separately (see below).

U, C, N, CE

Cable length: 2 m

C200H-CN222

N

Cable length: 2 m (for CPUs complying with EC directives)

C200HS-CN222

CE

Connects the peripheral port on the CQM1H to a personal com- CS1W-CN114 puter or Programming Console through a CQM1-CIF01/02 cable.

CE

■ CX-Programmer (Windows) Name CX-Programmer (V1.2 or later)

Specifications CD-ROM, OS: Windows 95, 98, Me, NT4.0, 2000, or XP

Model WS02-CXPC1-E-V3@

International standards ---

■ CX Protocol (Windows) Name CX-Protocol

Specifications Protocol macro software OS: Windows 95, 98, Me, NT4.0, 2000, or XP

Model WS02-PSTC1-E

International standards ---

■ Support Software Product

Model

International standards

Expansion Memory Unit

CPM1-EMU01-V1

---

EEPROM (256 K)

EEROM-JD

---

Maintenance Products Product

Function

Model

Battery

Backs up memory in the CPU Unit.

End Cover

Connects to the I/O Unit located on the extreme CQM1H-TER01 right

70

CPM2A-BAT01

International standards --U, C, CE

Page 68

Ordering Information

Programming Device Connecting Cables

Programming Device Connecting Cables Name

Specifications

Model

Connecting Cables (Peripheral port to Programming Device (computer))

Connects to Programming Console or CQM1-CIF01/02.

Connecting Cables (Peripheral port to RS-422)

Peripheral port to RS-422 conversion cable (length: 0.2 m)

CQM1H-CIF12

U, C, CE

D-Sub 9-pin computer cable (length: 2 m)

CS1W-CN226

CE

Connecting Cables (RS-232C port to Programming Device (computer))

CS1W-CN114

International standards

Connects to a D-Sub 9-pin port of an IBM PC/AT or compatible CQM1-CIF02 computer. (Use together with the CS1W-CN114.) Length: 3.3 m

CE U, C, N, L, CE

D-Sub 9-pin computer cable (length: 6 m)

CS1W-CN626

CE

D-Sub 9-pin receptacle (length: 0.1 m)

CS1W-CN118

CE

D-Sub 9-pin computer cable (length: 2 m)

XW2Z-200S-V

---

D-Sub 9-pin computer cable (length: 2 m) (anti-static)

XW2Z-200S-CV

---

D-Sub 9-pin computer cable (length: 5 m)

XW2Z-500S-V

---

D-Sub 9-pin computer cable (length: 5 m) (anti-static)

XW2Z-500S-CV

---

USB-Serial Conversion Cable

Converts between USB and RS-232C, cable length: 0.5 m. PC Driver included (CD-ROM).

CS1W-CIF31

N, CE

RS-422 Adapter

Converts peripheral port levels, cable length: 0.2 m.

CQM1-CIF121

U, C, CE

71