The text of a manual · part 1 of 6
DP2000-P, DP9000-P Process Indicators, pages 1 to 10
Pages 1 to 10 of 60
The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omega DP2000
Page 1
10288ML-98B Cover M1390 12/10/98 8:18 AM Page
Where Do | Find Everything | Need for
Y2K
Process Measurement and Control? Made in the USA ear 2000
OMEGA...Of Course! C € omplant TEMPERATURE
& Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
[ Wire: Thermocouple, RTD & Thermistor
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE @ Transducers & Strain Gauges
& Load Cells & Pressure Gauges
& Displacement Transducers
@& Instrumentation & Accessories
FLOW/LEVEL
( Rotameters, Gas Mass Flowmeters & Flow Computers & Air Velocity Indicators
& Turbine/Paddlewheel Systems
Totalizers & Batch Controllers pH/CONDUCTIVITY
& pH Electrodes, Testers & Accessories
4 Benchtop/Laboratory Meters i Controllers, Calibrators, Simulators & Pumps & Industrial pH & Conductivity Equipment
DATA ACQUISITION
& Data Acquisition & Engineering Software Communications-Based Acquisition Systems
& Plug-in Cards for Apple, IBM & Compatibles
& Datalogging Systems
W& Recorders, Printers & Plotters
HEATERS
Heating Cable
& Cartridge & Strip Heaters
& Immersion & Band Heaters
& Flexible Heaters
(& Laboratory Heaters
ENVIRONMENTAL ( x x )- MONITORING AND CONTROL DP2 P, [4 Metering & Control Instrumentation DP9000-P a Refractometers.
amps & Tubin le & Air, Soil & Water Monitors Process Indicators
& Industrial Water & Wastewater Treatment i pH, Conductivity & Dissolved Oxygen Instruments
10288ML-98 Rev. B Mi390/1298 http://www.omega.com e-mail: info@omega.com
Page 2
10288ML-98B Cover M1390 12/10/98 7:59 AM Page omega .com ‘| MHouEcCA +
OMEGAnet~ On-Line Service Internet e-mail hitp://www.omega.com info@omega.com
Servicing North America:
USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047
Tel: (203) 359-1660 e-mail: info@omega.com Canada: 976 Bergar
Laval (Quebec) H7L5A1
Tel: (614) 856-6928 e-mail: canada@omega.com
FAX: (203) 359-7700
FAX: (514) 856-6886
For immediate technical or applicati ist % USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA™ Customer Service: 1-800-622-2378 / 1-800-622-BEST™ Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN™ TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico and Latin America: Tel: (95) 800-TC-OMEGA™ En Espaiiol: (203) 359-7803
Servicing Europe: Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: (31) 20 6418405 FAX; (31) 20 6434643 Toll Free in Benelux: 06 0993344 e-mail; nl@omega.com
Czech Republic: ul. Rude armady 1868, 733 01 Karvina - Hranice Tel: 420 (69) 6311899 FAX: 420 (69) 6311114 e-mail: czech@omega.com
France: 9, rue Denis Papin, 78190 Trappes Tel: (33) 130-621-400 Toll Free in France: 0800-4-06342 e-mail: france@omega.com
G y/Austria: Daiml 26, D-75392 Deckenpfronn, Germany Tel: 49 (07056) 3017 FAX; 49 (07056) 8540 Toll Free in Germany: 0130 11 21 66 e-mail: germany@omega.com
United Kingdom: 5 Swannington Road, PO. Box’ 2 Omega Drive, ISO 9002 Certified igh Astley, Lei i Irlam, \
LE9 6TU, England M44 SEX, England
Tel: 44 (1455) 285520 Tel: 44 (161) 777-6611
FAX: 44 (1455) 283912 FAX: 44 (161) 777-6622
Toll Free in England: 0800-488-488 e-mail: uk@omega.com ltis the Policy of OMEGA to » comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon it The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient connected applications.
This device is marked with the international hazard symbol. It is important to read the Setup Guide before installing or commissioning this device as it contains important information relating to safoty and EMC.
FAX: (95) 203-359-7807 e-mail: espanol@omega.com
FAX: (33) 130-699-120
S88 WARRANTY/DISCLAIMER Sissi:
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA's customers receive maximum coverage on each product.
if the unit should malfunction, it must be returned to the factory for evaluation. OMEGA's Customer Service Department will issue an Authorized Return {AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pk d to offer on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES: OR REPRESENTATIONS OF ANY KIND WHATSOEVER, IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on warranty indemnification, or otherwise, shall not exceed the pi hase Price of the component upon hich lability | is based. In no event shall ‘OMEGA be liable for
CONDITIONS: Equipment sold by OMEGA | is! not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or {2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused n any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/
DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
8 RETURN REQUESTS / INQUIRIES SS Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (iN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then pe mares on the outside of the return package and on any correspondence. The for ig charges, freight, i and proper to prevent breakage it in transit.
FOR WARRANTY RETURNS, please have FOR NON-WARRANTY REPAIRS, consult the following information available BEFORE | OMEGA for current repair charges. Have contacting OMEGA: the following information available 1. P.O. number under which the product BEFORE contacting OMEGA: was PURCHASED, 1. P.O. number to cover the COST of the repair, 2. Model and serial number of product, and 3. Repair instructions and/or specific 3. Repair instructions and/or specific problems relative to the product. problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our the latest in and
2. Model and serial number of the product under warranty, and
OMEGA is a regis of OMEGA i INC. © Copyright 1998 OMEGA ENGINEERING, INC. any rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced medium or ble form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.
Page 3
TABLE OF CONTENTS
SAFETY CONSIDERATIONS... 0.1... ee een ee ii
DP2000 MAIN ASSEMBLY
1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
SpecificationS 2... 0... ee eee eee eee eae 1 Mechanical Assembly and Installation ........ 0.0.00. ccc eee ees 4 Power & Signal Input Connections ........ 0... ee eee es 5 Configuration Procedure 6... ee eee eee teens 6 Configuration Charts ... 0.0... cece eee teen enn nnes 7 Tests and DiagnosticS 61... eens 9 Main Board Connector Pin Assignments ........... 0.000 eee ee eens 10 DrAWINGS 2... eee tees 11
DP9000 MAIN ASSEMBLY
9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0
Specifications ....... 0... ce eee eee eee eee eens 16 Mechanical Assembly and Installation ............. 00 cc eee eee ees 19 Power & Signal Input Connections ........ 0... es 20 Configuration Procedure 1.0.0.0... ccc ee eens 21 Configuration Charts ........ 0... ccc nett tne 22 ‘Tests and Diagnostics ....... 0... ccc eee eee ens 25 Main Board Connector Pin Assignments ........... 00000 c cece eee eee 26 DrAWiNgS «1... et eee eee eee ees 27
SIGNAL CONDITIONER BSCP
17.0 18.0 19.0 20.0 21.0 22.0 23.0 24.0
Specifications 2.0... ee tee eee eee eee eens 30 Signal Input Connections ......... 0... eee eee eens 32 Test and Diagnostics 2.0.0... eee eee eee eens 33 Configuration Procedure ........ 0. cc ccc ee ee ee eee 34 Configuration Charts 1.0.0... 0... ce ee eee ete teens 41 Calibration for DP2000-P .... 1.1... ee eee ees 48 Calibration for QQ000-P .. 1... ete eee en aes 49 DraWINGS 21. ee eee ee eee eee eee eben anne 50
INSTALLATION INSTRUCTIONS
25.0
Digital Panel Meter Installation Instructions ........... 0.0.00 e eee eee ee 52
Page 4
SAFETY CONSIDERATIONS before installing or commissioning this device as it contains important information relating to
This device is marked with the international Caution symbol. It is important to read this manual /|\we and EMC (Electromagnetic Compatibility).
Unpacking & Inspection see Unpack the instrument and inspect for obvious shipping damage. Do not attempt to operate the unit if damage is found.
This instrument is a panel mount device protected in accordance with Class | of EN 61010 (115/230 AC power connections). Installation of this instrument should be done by Qualified personnel. In order to ensure safe operation, the following instructions should be followed.
This instrument has no power-on switch. An external switch or circuit-breaker shall be included in the building installation as a disconnecting device. It shall be marked to indicate this function, and it shall be in close proximity to the equipment within easy reach of the operator. The switch or circuit-breaker shall not interrupt the Protective Conductor (Earth wire), and it shall meet the relevant requirements of IEC 947-1 and IEC 947-3 (International Electrotechnical Commission). The switch shall not be incorporated in the mains supply cord.
Furthermore, to provide protection against excessive energy being drawn from the mains supply in case of a fault in the equipment, an overcurrent protection device shall be installed.
The Protective Conductor must be connected for safety reasons. Check that the power cable has the proper Earth wire, and it is properly connected. It is not safe to operate this unit without the Protective Conductor Terminal connected.
Do not exceed voltage rating on the label located on the top of the instrument housing.
Always disconnect power before changing signal and power connections.
Do not use this instrument on a work bench without its case for safety reasons.
* Do not operate this instrument in flammable or explosive atmospheres.
¢ Do not expose this instrument to rain or moisture.
¢ Unit mounting should allow for adequate ventilation to ensure instrument does not exceed Operating temperature rating.
¢ Use electrical wires with adequate size to handle mechanical strain and power requirements. Install without exposing bare wire outside the connector to minimize electrical shock hazards.
EMC Considerations
Whenever EMC is an issue, always use shielded cables.
¢ Never run signal and power wires in the same conduit.
Use signal wire connections with twisted-pair cables.
Install Ferrite Bead(s) on signal wires close to the instrument if EMC problems persist.
Page 5
1.0 MAIN ASSEMBLY DP2000 SPECIFICATIONS
1.1
GENERAL The DP2000 main assemblies are identified by an initial designator (DP2) plus a power/display option numeral, zero thru nine (0-9).
The following table identifies the main assembly types:
Display
Type 120 Vac | 240 Vac] 9-32 Vdc} 5 Vac 24 V ac LED DP20 DP22 DP24 DP26 DP28 LCD DP21 DP23 DP25 DP27 DP29
The OMEGA Digital Panel Meter/Controller consists of a main assembly, signal conditioner and interface options (if ordered) all housed in a 1/8 DIN case.
The main assembly consists of a main board and a display board which is permanently attached to it at a 90 degree angle.
The main board provides mounting for the power supply, circuit components, and connectors for plugging in the signal conditioner, optional analog card, and optional controller/communications interface card (requires removal of a bypass push-on jumper).
The display board includes the analog-to-digital converter, the LED or LCD display and the push-on jumper for programming the decimal points. Decimal point programming may also be done from the main board connector (J1).
Page 6
1.2 POWER
1.3
1.4
1.5
1.6
AC Models: Common Mode Voltage: DC Models:
Source Impedance: Ripple: Power Consumption:
DISPLAY LED:
Lens Color: LCD:
Lens color: Range:
Overload Indication:
CONVERSION
Technique:
Signal Integration Period:
Reading Rate:
ENVIRONMENTAL
Operating Temperature (Ambient):
Storage Temperature: Humidity: MECHANICAL
Case Material: Weight:
24/120/240V +10/-15% 47-63 Hz
1500 Vp test (854 Vp per IEC spacing)
5V +5% (5V return common to signal LO)
9-32V (300V isolation from 9-32V return to signal LO) 3 Ohms
250mV maximum
5 watts maximum
14.2mm (0.56 in), 7-segment light emitting diode Red
12.7mm (0.50 in), 7-segmenit liquid crystal
Clear
0 to +1999
Three least significant digits blanked, "1" or "-1" displayed
Auto-zero, dual slope, average value 100ms, nominal
2.5/s, nominal
0-60 C -40 to 85 C To 95% RH, non-condensing, 0-40 C
UL-rated 94V-0, polycarbonate 0.57 kg (with interface board)
Page 7
CASE, UPPER CLAMP SCREW
CONTROL INTERFACE SLIDE CLAMP EXCITATION VOLTAGE MODEL & POWER TAB SERIAL NO. LENS OF] SLIDE CASE RETAINER
CONTROL INTERFACE
INTERCONNECT ‘4 BOARD OPTION CABLE TERMINAL BLOCK COVER ZERO ADJ. Sti J {/ | \ INPUT POWER AQ SIGNAL CONDITIONER ANALOG SF, BOARD OUTPUT Sy BOARD MAIN BOARD SPAN ADJ. | DECIMAL POINT SELECT DISPLAY BOARD CASE, LOWER
Page 8
2.0 MECHANICAL ASSEMBLY & INSTALLATION 2.1 PANEL MOUNTING PROCEDURE (SEE FIGURE 1) 1. Remove the main board edge connector (J1), if installed. 2. Remove the interface board connector (J2), if installed.
3. Loosen two clamp screws on the rear of the case enough to rotate the two slide clamps.
4. Slide the two slide retainers toward the rear of the case and remove them. 5. From the front of the panel, insert the meter into the panel cutout.
6. Slide the slide retainers back onto the case and push up tightly against the rear of the panel.
7. Rotate the slide clamps back into their original position and tighten enough to hold the case in place. Overtightening can break the clamps.
8. Install any connectors removed. 2.2 LABELS (SEE FIGURE 2)
MODEL & POWER TOP
EXCITATION VOLTAGE
SERIAL NO
POWER CONTROL SIGNAL INTERFACE
NOTE: READ LABELS FROM THE REAR
FIGURE 2. LABEL PLACEMENT
Page 9
3.0 POWER & SIGNAL INPUT CONNECTIONS
WARNING: Incorrect power input can damage your OMEGA PANEL METER.
3.1 POWER CONNECTIONS
Terminal | pee } ® ® Connettion | 1¥YevsVvarvsve Oh. nen ncencecneaVO 2
7 3
3.2 SIGNAL INPUT CONNECTIONS
Terminal P +4 - )* al Connection @) @) 4 p¥2vavavsvle OpwecncceccceneecesaVO 5 7 6 REAR TERMINAL VIEW pi, Terminal @laaal i 1i@ Connection 4567 4 Op i enccccccanaceeavO 5 6 7 a Terminal | L - 4 Connection @) @) 1 1¥V24NaVEOU5 VE 3
AC Wire Versions Color AC power HI Black AC power LO (neutral) White AC power GND Green DC Versions No connection DC power +
DC power - (return)
6 Terminal Versions Signal Analog GND Signal LO Signal HI
7 Terminal Versions Signal
-E (Excitation return) -S (Signal LO input) +S (Signal HI input) +E (Excitation output)
Page 10
4.0 CONFIGURATION PROCEDURE
This procedure is used to set the decimal point of the display and interface board signal bypass selections for the configuration of the OMEGA DP2000 Display and power options (DP20 through DP29).
The main assembly can be configured using the push-on jumpers provided or already positioned on the pin forests. Pin forest designations are shown at the top of every page of the configuration charts.