Spec sheet · Omega
1/8 DIN Versatile Process Monitors, Configurable DP2000 Series
Spec sheet9 pagesPDF 466 KB
Spec sheet and ordering guide for the OMEGA DP2000 series 1/8 DIN configurable digital indicator/controllers and their option boards.
Covers · 1 model
The models it covers
Summary
What is in it
Catalog spec sheet for the OMEGA DP2000 series of 1/8 DIN digital indicator/controllers, built to order from a motherboard (LED or LCD display and operating power), an analog output, a control output and a signal conditioner input. It gives general specifications and dimensions, then describes each analog output, the dual-setpoint, proportional, time-proportioning, BCD and single-setpoint control outputs, and the input signal conditioners for DC and AC voltage and current, process signals, frequency, thermocouples, RTDs and strain gages.
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A catalog spec section (pages D-79 to D-86) for the OMEGA DP2000 series of configurable 1/8 DIN digital indicator/controllers, titled Versatile Process Monitors. It explains how a model number is built from a motherboard (display and power), an analog output, a control output and a signal conditioner input. It then gives the specifications of each option.
- Device
- 1/8 DIN digital indicator/controller built to order: display, power, input type and range, analog output and control output p. 1
- Display
- Red LED 14.2 mm (0.56") or LCD 12.7 mm (0.50"), 7-segment; range 0 to ±1999 p. 2
- Power
- AC: 120/240 Vac, 49 to 440 Hz, or 24 Vac; DC: 5 Vdc ±5%, 9 to 32 Vdc or 26 to 56 Vdc (9 to 32 and 26 to 56 Vdc isolated) p. 1, 2
- Inputs
- DC voltage or current, AC average or RMS voltage or current, process signal (with or without 15 Vdc excitation), frequency/rate, J, K or T thermocouple, RTD, strain gage p. 1
- Analog outputs
- 1 mV/count on all units; options 0 to 5 Vdc, 0 to 10 Vdc, 0 to 1 mA, and 4 to 20 mA internally driven, externally driven or isolated p. 3
- Control outputs
- Dual setpoint 10 A relay (SPDT), proportional 4 to 20 mA, proportional/time proportioning 2 A relay, isolated parallel BCD, single setpoint 10 A relay (SPDT) p. 1
- Relay ratings
- Dual setpoint: 10 A at 120 Vac and 240 Vac; time proportioning: 2 A at 240 Vac; single setpoint form C: 10 A at 30 Vdc or 240 Vac, resistive p. 3, 4
- Conversion
- Auto-zero dual slope, 100 ms integration, 2.5 readings per second nominal p. 2
- Environment
- Operating 0 to 60°C (32 to 140°F); storage -40 to 85°C (-40 to 185°F); humidity to 95% RH non-condensing at 0 to 40°C p. 2
- Temperature inputs
- Type K thermocouple 0 to 1260°C (32 to 1999°F); Pt 100 Ω RTD at 1° resolution -200 to 830°C (-328 to 1526°F) p. 7
- DC voltage ranges
- ±0.1999V, ±1.999V, ±19.99V, ±199.9V; accuracy ±0.05% of reading ±1 count p. 4
- BCD output
- Isolated (350V) BCD on 14 parallel lines plus polarity and data-ready, 5 Vdc TTL; needs a 5V at 100 mA supply such as PSP-5 or PST-5 p. 4
- Case
- 94 V-0 UL-rated polycarbonate; 0.57 kg (1.26 lb) with controller; panel 0.8 to 6.4 mm (0.03 to 0.25 in.) thick p. 2
- Panel punch
- DPP-5, 1/8 DIN panel punch p. 1
What this sheet walks you through
- Building a DP2000 model number from motherboard, analog output, control output and input p. 1
- Choosing a motherboard for display and power p. 2
- Choosing an analog output p. 3
- How the dual setpoint, proportional and time-proportioning controllers work p. 3
- Using the parallel BCD output and the single setpoint controller, latched or fail-safe p. 4
- Picking the signal conditioner range code from the required gain p. 5, 6, 8
- Sizing an external resistor for load cell zero offset p. 5
- Thermocouple and RTD input models p. 7
Good to know
- The E series strain gage input is factory-set to one of 11 ranges; changing the range in the field is not recommended. p. 5
- A power supply is required with a parallel BCD output card. p. 4
- In fail-safe mode the single setpoint relay drops out on power failure, signaling an alarm. p. 4
- Frequency inputs take at most 130 Vrms. p. 6
- Maximum display is ±1999 counts. p. 5
Questions this sheet answers
What power can the Omega DP2000 run on?
AC versions take 120/240 Vac or 24 Vac; DC versions take 5 Vdc, 9 to 32 Vdc or 26 to 56 Vdc. p. 2
Can the DP2000 read a thermocouple?
Yes, with J, K or T thermocouple input boards; Type K covers 0 to 1260°C (32 to 1999°F). p. 7
What outputs does the DP2000 have?
A standard 1 mV/count analog output, six optional analog outputs, and five control output choices including relay setpoint controllers and parallel BCD. p. 3
How do I choose the range code for a strain gage or process input on the DP2000?
Work out the gain as full scale span over signal span, then pick the code whose minimum and maximum gain bracket it. p. 5
The whole text · 1 part
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file




