For the Oakton OaktonLog DataLogger

Page 201

Specifications Memory Capacity (DT175 only): 2,000 recording samples Connectors: 4-pin flat connection to the OaktonLog 4-pin flat connection to any OaktonLog external sensor Screw terminal for External DC supply, Connection to external sensor, External control switch and additional Contact sensor (the additional contact sensor is available in DT175 only) Power supply: Internal: lithium battery, 3.6V

201

Page 202

Specifications Battery Life - approximately 100,000 transmissions, replaceable External: 6-30V, minimum 300mA RF transmission (DT175 only): EMC conformant to ETS 300-683 Type approved to ETS 300-220. Usable range to 300m (75m indoors) 418 (UK) & 433.92MHz (Euro) versions 1mW on 418 MHz, 10mW on 433.92MHz 2nd harmonic <-60dBc 16cm wipe antenna CE and FCC standard compliance

202

Page 203

Specifications OaktonLog Plus Receiver Communication Ports: RS232 at 19.2Kbps USB at 1.5Mbps Power Supply: External: 9-12VDC, minimum 300mA Red LED indicating RF signal Green LED indicating valid data being received RF Receiver: European version Frequency: 433.92MHz

203

Page 204

Specifications Type approved to ETS 300-220 Usable range: To 300m (75m indoors) North American version Frequency: 914.5MHz Usable range: To 120m (30m indoors) Antenna: SMA connector Supplied with rubber whip antenna (with a hinge) Dimensions: 10×9×2.5 cm

204

Page 205

Specifications CE and FCC standard compliance

Software MicroLab Software Features Runs on WINDOWS 98/2000/ME/XP and NT Fast data download from the OaktonLog Graphic visualization of the OaktonLog data Data displayed in graphs and tables Data export to EXCEL Graphic analysis tools such as Markers, Zoom OaktonLog Setup windows, for setting up the OaktonLog unit ID, sample rate, sensors and alarm level Sampling rate: Once every 10 seconds to 2 hours Definition of additional external sensors

205

Page 206

Specifications OaktonLog sensor calibration Display of OaktonLog Battery Level Integration with the wireless OaktonLog Cradle, Receiver and Repeater Display of daily reports of a fleet of data loggers Visual alarm levels on the graph and table MicroLab System Requirements Software Windows 98 or later Internet Explorer 4.0 or later (Internet Explorer 5 can be installed together with MicroLab, as it ships with the product)

206

Page 207

Specifications Hardware Pentium 300MHz or higher 32 MB RAM (64 MB recommended) 5MB available disk space for the MicroLab application MicroLab Plus Software Features Wireless communication with up to 200 OaktonLog s Real-time temperature and humidity and external sensor readings Data display in meters or graphs Visual and sound alarm when the data reading exceeds a minimum or maximum alarm threshold for temperature or humidity E-mail alarm notification

207

Page 208

Specifications Battery level display Automatic data saving to an Excel file Data Map allowing the users to easily view many OaktonLog data loggers on one screen OaktonLog Setup windows, for setting up the OaktonLog unit ID, sample rate, sensors and alarm level Sampling rate: Once every 10 seconds to 2 hours Definition of additional external sensors MicroLab Plus System Requirements Software Windows 98 or later Internet Explorer 4.0 or later (Internet Explorer 5 can be installed together with MicroLab, as it ships with the product)

208

Page 209

Specifications Hardware Pentium 300MHz or higher 32 MB RAM (64 MB recommended) 5MB available disk space for the MicroLab Plus application

209

Page 210

Figures Appendix A: Figures Figure 1: Connecting OaktonLog..................................................... 31 Figure 2: OaktonLog battery life...................................................... 34 Figure 3: Replacing the battery ........................................................ 36 Figure 4: Define New Sensor........................................................... 83 Figure 5: MicroLab’s Communication Setup dialog box ................. 85 Figure 6: OaktonLog and Cradle.................................................... 168 Figure 7: External control switch wiring diagram.......................... 173 Figure 8: Cradle’s screw terminals ................................................ 176 Figure 9: Receiver layout............................................................... 179