Page 1 of Oakton LoggerPlus and OaktonLog DataLogger Spec Sheet

Spec sheet · Oakton

Oakton LoggerPlus and OaktonLog DataLogger Spec Sheet

Spec sheet2 pagesPDF 82 KB

Both pages are below, each with its text.

Download the PDF82 KB

Filed with · 2 models

Also filed with these models on the old site

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

A two-page OAKTON product sheet for the TempLog temperature data logger and the RH/TempLog temperature and humidity data logger. It does not name the LoggerPlus or OaktonLog DataLogger it is filed under. It describes the display, memory, infrared and RS-232 download, software, remote sensors and the infrared printer, with specifications and order numbers.

Device
Compact loggers that record temperature (TempLog) or temperature and humidity (RH/TempLog) for months p. 1
Memory
Up to 16,000 time/date stamped readings p. 1
Temperature range
-30 to 50°C / -22 to 122°F, accuracy ±0.6°C / ±1.1°F p. 2
Humidity
RH/TempLog only: 0 to 100% RH; ±3% from 0 to 90% RH at room temp, ±6% from 90% to 100% RH p. 2
Outputs
IRDA infrared interface to a printer or computer; RS-232 cable connection to a computer p. 2
Power
Internal lithium battery, 3.6 V TL5101, about two years life (may be less with an external sensor); replacement WD-35710-65 p. 2
Sampling rate
Once per 10 seconds to once per two hours, set through the software p. 2
Housing
TempLog: IP65 rated; RH/TempLog: IP60 rated p. 2
Software and cable
WD-35710-50 software/serial cable, 8.5 ft (2.5 m) to a 9-pin serial port; software runs on Windows 3.x and Windows 95/98/NT/ME p. 2
Order numbers
WD-35710-00 TempLog; WD-35710-10 RH/TempLog; WD-35710-60 TempLog kit; WD-35710-62 RH/TempLog kit p. 2
Remote sensors
WD-35710-70 temperature (-50 to 100°C), WD-35710-72 current (0 to 20 mA), WD-35710-74 voltage (0 to 10 V), WD-35710-76 contact; 8.2 ft cable each p. 2
Printer accessories
WD-37455-70 infrared printer; WD-37455-82 paper; WD-35615-07 (110 VAC) and WD-35615-08 (220 VAC) AC adapters, 9 VDC p. 2
Display
Two digit LCD with mode indicators; shows current readings and min/max over the last 1-24 hours or 1-30 days p. 1, 2
Size and weight
2.8" dia x 0.9" D (7.2 cm dia x 2.3 cm D); 0.2 lb (0.1 kg) p. 2

What this sheet walks you through

  • Setting the logging interval, start mode and full-memory behavior in the software p. 1
  • Viewing minimum and maximum readings on the display p. 1, 2
  • Printing max/min data on the infrared printer p. 2
  • Graphing and exporting data with the software p. 1
  • Uses in shipping, labs, greenhouses, cold rooms and museums p. 2

Good to know

  • The software/cable package is needed to change factory settings or download data; one package serves several loggers. p. 1
  • Battery life may be shorter than two years when an external sensor is used. p. 2
  • The sampling rate and alarm limits can only be set with the software. p. 1

Questions this sheet answers

How many readings can the OAKTON TempLog store?

Up to 16,000 time and date stamped readings. p. 1

What battery does the TempLog use and how long does it last?

An internal 3.6 V TL5101 lithium battery lasting about two years, less with an external sensor. p. 2

How do I get data off the RH/TempLog?

Download it to a computer through the infrared port or the WD-35710-50 serial cable with the software, or print max/min data on an infrared printer. p. 1, 2

How accurate is the RH/TempLog humidity reading?

±3% from 0 to 90% RH at room temperature and ±6% from 90% to 100% RH. p. 2

The file

Size and text

Pages2
PDF82 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Oakton LoggerPlus and OaktonLog DataLogger Spec Sheet

The text of page 1, from the PDF itself

TempLog & RH/TempLog Automatically log temperature and humidity readings for months, then download data to your computer or printer! Use for long term temperature and humidity datalogging

1

ideal for shipping or storage, laboratories, factories, cold rooms, greenhouses, and more!

year warranty

ISO 9001 vendor CERTIFIED

Memory holds up to 16,000 time/date stamped readings Compact splashproof housing TempLog is IP65 rated; RH/TempLog is IP60 rated

Large LCD display lets you immediately view current conditions; displays min/max values by day(s) or hour(s) with a quick button press

Infrared (IRDA) communication document max/min values quickly with optional IR printer

Selectable sampling rate sample from once per 10 seconds to once per two hours (software required)

Selectable alarm setting display flashes when set limits are passed (software required)

External sensor input for a temperature, contact, voltage, or current sensor

Software features Customize logging parameters set logging interval, delayed or immediate start, overwrite data or stop when full

Left: TempLog and RH/TempLog shown at actual size. Above right: These loggers accept a remote temperature, contact, voltage, or current sensor. Middle right: Infrared port lets you download readings directly into your printer or computer with an IRDA port. Bottom right: Software lets you manipulate data and create data graphs.

Stores 20-character message lets you “name” device for later identification

Graphic or tabular display print or export data for use in spreadsheets

Powerful display options zoom in and adjust scale to focus on most important data

Pinpoint data for quick analysis point and click to see individual points or difference between two points

The OAKTON TempLog and RH/TempLog let you effortlessly track important temperature and humidity data for months! These loggers automatically save up to 16,000 measurements on selectable intervals. The LCD display shows you current conditions. Press a button to view minimum and maximum readings over the last 1-24 hours / 1-30 days. Point the logger toward an optional IR printer for a hard-copy printout of max/min data. Or, download data to your computer via the infrared port or cable. Software lets you graph, analyze, or export your data. The compact splashproof housing guarantees that each logger will function properly even in busy or rugged areas. The long lasting, replaceable battery powers your logger for two years. Choose from temperature or temperature/humidity models. Software/cable package is required to change factory settings or download data. One package can be used with multiple loggers (order software separately). See the back of this sheet for ordering information and complete specifications.

…setting the standard, again and again™

Temperature / Humidity DataLogging

temperature and humidity datalogger monitors

Page 2 of Oakton LoggerPlus and OaktonLog DataLogger Spec Sheet

The text of page 2, from the PDF itself

Set a start time and a sample time of once per 10 seconds to once per 2 hours through the software package.

Te m p L o g & R H / Te m p L o g

  • Applications • Shipping and Storage: Place on trucks, airplanes, trains, or in warehouses to safeguard products such as produce, medical supplies, industrial chemicals, and other temperature / humidity sensitive products. Laboratories and Industrial Plants: Ensure that ambient temperature and humidity levels remain stable 24 hours a day to keep your equipment in optimal working condition. Use external current and voltage sensors with transmitters. Greenhouses and Cold Rooms: Record fluctuations in temperature and humidity over time - download readings to your computer to graph your data. These loggers let you discover potential problems before they become costly. Museums and Libraries: Make sure conditions aren’t harmful to valuable archives and collections.

Select the sensors you need to use in your next data recording (temperature, humidity, or external sensor) via the software package.

Large display shows current readings. Press a button to show minimum and maximum readings by hour(s) or by day(s).

  • Specifications • Mode Range Resolution

Temperature –30 to 50°C / –22 to 122°F 0.5°C / 1°F

Accuracy

±0.6°C / ±1.1°F

Humidity (RH/TempLog only) 0 to 100% RH 0.5% ±3% from 0 to 90% RH at room temp; ±6% from 90% to 100% RH

Memory: stores up to 16,000 measurements Output: Infrared: IRDA (infrared data association) interface to printer or computer with IRDA port RS-232: Cable connection to your computer (order cable/software package separately below) Sampling rate: selectable via software from once per 10 seconds to once per two hours Software: Required to download readings to a computer and to set sampling rate (order software separately below). Software can be used with multiple loggers. Software is compatible with Windows 3.x and Windows 95/98/NT/ME.

Display: two digit LCD display, 3⁄8"H, with mode indicators Housing: TempLog: IP65 rated RH/TempLog: IP60 rated External sensor: optional. See “Remote Sensors” below Power: internal lithium battery, 3.6 V TL5101. Battery life is two years (may be less with external sensor) Dimensions: 2.8" dia x 0.9"D (7.2 cm dia x 2.3 cm D) Weight: 0.2 lb (0.1 kg)

  • Ordering Information • Loggers Shipping weight for loggers and logger kits 2 lbs (0.9 kg). Easy access connections on unit back for computer cable (order separately) or external temperature sensor.

WD-35710-00 OAKTON TempLog WD-35710-10 OAKTON RH/TempLog WD-35710-50 Software/serial cable. Software is required to download readings to a computer and to set sampling rate. Software can be used with multiple loggers. Cable is 8.5 ft (2.5 m) long and connects to computer 9-pin serial port WD-35710-60 OAKTON TempLog kit, includes TempLog, software and serial cable. WD-35710-62 OAKTON RH/TempLog kit, includes RH/TempLog, software and serial cable. WD-35710-65 Replacement battery

Infrared printer This infrared printer is ideal for on-site documentation. Transfer data by infrared light without the use of cables - just position the OAKTON logger IRDA port near the printer’s IRDA port. Quick-reference instruction card lets you view instrument directions at a glance.

WD-37455-70 Infrared printer includes one roll of paper and four AA batteries. Shpg wt 1.4 lbs (0.6 kg) WD-35615-07 AC adapter, 9 VDC to 110 VAC. Shpg wt 1.3 lbs (0.6 kg) WD-35615-08 AC adapter, 9 VDC to 220 VAC. Shpg wt 1.3 lbs (0.6 kg) WD-37455-82 Replacement printer paper, 2.25"W x 80 ft L. Pack of three rolls

Remote sensors Use remote sensors with Oakton loggers to display and log additional external readings. Use temperature sensor to measure remote temperature in air, liquids, soil and more. Current, voltage, and contact sensors can be scaled to match range and units of your transmitter or instrument output. Each sensor includes 8.2 ft (2.5 m) cable. WD-35710-70 Temperature sensor. Range –50 to 100°C. 3.25" L x 0.25" dia stainless steel probe WD-35710-72 Current sensor. Range 0 to 20 mA WD-35710-74 Voltage sensor. Range 0 to 10 V WD-35710-76 Contact sensor Optional portable printer lets you download readings through the infrared port - no cables needed!

Bulletin Log A1R2

  • ORDER FROM •

Printed in the U.S.A. 8/01 OAKTON TM Reg. #1,692,543. We reserve the right to make changes, improvements and modifications to products shown. All prices subject to change without notice. OAKTON Instruments are available only through authorized OAKTON distributors.