Page 71
SECTION 4
"
Configuration
Uploading New Versions You would normally upload RC4030E Gateway software from a PC into the RC4030E Gateway when you are installing a new version of software. “Upload” is an appropriate term because, to the local PC, the RC4030E Gateway appears as a remote host computer. (A communications software package on a local PC is designed to upload data to a remote host computer.) Your Service Representative or Systems Engineer orders a disk containing the new version, or arranges for you to download it onto your PC through the bulletin board at Norand. The software is usually located in a directory named a. The directory contains a “gateway” file and four “host” files. You can copy the directory onto your PC’s hard drive or leave it on the disk. Before you begin the upload process do the following: 1. Establish a local session with the RC4030E Gateway. 2. Write down the DOS pathnames of the FLASH files because you will need to enter the pathnames during the upload process. The following pathname applies if the files in directory a are located on hard drive c: c:\a\* where c: is the hard drive, \a is the directory in which the “gateway” and “host” files are located, and \* selects all files in directory a. 3. Read your communications software user guide to find out how your package uploads files. For example, PROCOMM PLUS for DOS uploads the FLASH files after you press [PAGE UP], select “Y-modem batch protocol” from a list of options, enter the DOS pathnames, and then press [Enter]. 4. Start the communications program. RC4030E Gateway User’s Guide
4-39
Page 72
SECTION 4
"
Configuration
5. To upload files into the RC4030E Gateway, refer to the following procedure. It lists the steps you need to follow and the commands to type. " NOTE:
The following procedure applies to RC4030E Gateway ROM Version 1.14 and above.
1. Reboot the RC4030E Gateway into ROM (command interpreter) mode. To do this, set switch #11 to ON, and then power cycle the RC4030E Gateway by unplugging it from the outlet and then plugging it back in. The gateway responds with: RB4030 ROM <Version> <Date> <Time>
2. Ensure the RC4030E Gateway rebooted into ROM mode: Command
RC4030E Response v
RB4030 ROM <Version> <Date> <Time>
3. Upload the RAM drive “gateway” file and “host” files from the PC and into the RC4030E Gateway’s RAM drive (c:): Command
RC4030E Response fx (and then upload procedure for your terminal emulation program)
C (RC4030E Gateway is waiting for upload to begin) and then 00 (after successful upload)
You can list the contents of the RAM drive by typing: fdc:
If the files loaded successfully, the RAM drive directory will resemble the following sample screen. The “RB4030” header file always appears first in the directory.
4-40
RC4030E Gateway User’s Guide
Page 73
SECTION 4
"
Configuration
The “gateway” and “host” files can be in any order: 01 02 03 04 05 06 00
RB4030 1fffbc 3270 1f8d70 AHOST 1efff8 GATEWAY 19f498 SDLC 19b338 5250 193d68
0 25084 36159 330534 16679 30101
03-24-96 05-11-96 03-24-96 04-18-96 04-18-96
10:54:50 13:18:26 10:54:00 15:16:14 12:53:46
V2.10 v2.10 V0.03 V2.10 V2.10
4. Erase the outdated FLASH files (512 KB), which are located in RC4030E Gateway directory a:: Command
RC4030E Response fe a:
00 (after FLASH files are erased, in about 2 minutes)
5. Copy the “gateway” file into FLASH memory so that it will correctly load into the first memory location: Command
RC4030E Response fc gateway a:
00 (after successful copy, in about 2 minutes)
The “gateway” file must load at absolute base address 500000h, the start address of FLASH. Therefore, the “gateway” file must be the first file loaded into FLASH. If the “gateway” file is not loaded first, the RC4030E Gateway will not work. Do not use a wildcard copy command (such as fc c: a:) to copy the files from the RAM drive into FLASH. A wildcard command loads the “RB4030” header file into FLASH first, which causes the “gateway” file to load after the “RB4030” header file. Besides, the “RB4030” header file does not need to be loaded into FLASH.
RC4030E Gateway User’s Guide
4-41
Page 74
SECTION 4
"
Configuration
6. After you copy the “gateway” file, individually copy the four “host” files into FLASH. They can be copied in any order:
" NOTE:
Commands
RC4030E Response fc ahost a: fc sdlc a: fc 3270 a: fc 5250 a:
00 (after successful copy, in about 2 minutes)
You can copy just the host files that apply to your system. For example, for 3270 SNA/SDLC communications, you need to copy only the “3270” host file and the “sdlc” host file.
You can list the contents of the FLASH drive by typing: fda:
If the “host” files loaded successfully, your FLASH drive directory will resemble the following sample screen. Note that because the “gateway” file was copied first, it is the first file loaded into FLASH and the first file listed in the directory. The remaining files -- the “host” files -- can be in any order: 01 02 03 04 05 00
GATEWAY 500000 AHOST 550b4c SDLC 5598b0 3270 55d9fc 5250 563c20
330534 36159 16679 25084 30101
03-24-96 05-11-96 04-18-96 04-18-96 04-18-96
11:54:00 13:39:27 16:16:14 14:46:50 14:53:46
V0.03 V2.10 v2.10 V2.10 V2.10
7. Reboot the RC4030E Gateway into FLASH mode by resetting switch #11 to OFF and power cycling the RC4030E Gateway again.
4-42
RC4030E Gateway User’s Guide
Page 75
SECTION 4
"
Configuration
Checking the FLASH and ROM Versions The RC4030E Gateway has two operating modes: FLASH and ROM. To check the current versions of FLASH and ROM installed in your RC4030E Gateway, you need a local PC with a terminal emulation program installed on it (for example, PROCOMM PLUS), the gateway, and one of these cables: An industry-standard null modem cable " For a 9-pin PC COM port, P/N 216-841-00X " For a 25-pin PC COM port, P/N 216-842-00X
"
Use the following procedure to check the current FLASH and ROM versions. 1. Ensure the RC4030E Gateway’s power supply is unplugged from the outlet. 2. Set switch #11 (command interpreter) to ON (closed). 3. Plug the 9-pin male connector on the cable into the female DIAG port on the bottom panel of the RC4030E Gateway. 4. Plug the 9-pin or 25-pin female connector on the other end of the cable into the designated COM port on the PC. 5. Start the terminal emulation program on the PC. 6. Power cycle the RC4030E Gateway by plugging its power supply into an outlet.
RC4030E Gateway User’s Guide
4-43
Page 76
SECTION 4
"
Configuration
7. The RC4030E Gateway displays current ROM information when it starts its power-up sequence (visible on the PC screen): RB4030 ROM <Version> <Date> <Time>
<Version> is the current ROM version. <Date> is the date this version of ROM was released. <Time> is the time this version was released. 8. To list the FLASH files with their date and version, type: fd a:
9. To resume normal operation set switch #11 (command interpreter) to OFF. 10. Power cycle the RC4030E Gateway by unplugging it from the outlet and then plugging it back in.
4-44
RC4030E Gateway User’s Guide
Page 77
Section 5
Installation "
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
This section describes how to do the following: " " " "
Mount the RC4030E Gateway Wire the gateway to 10BASE2 and 10BASE-T cable Connect the gateway to the host Verify gateway operation
Mounting the RC4030E Gateway After the RC4030E Gateway has been configured, you can mount it vertically on a wall or post, or horizontally on a tabletop. Intermec recommends that the RC4030E Gateway be mounted vertically so that it will be drip-resistant. An RC4030E Gateway mounted in any other position must be protected from dripping fluids. When mounting the gateway, do the following: "
"
"
Ensure the LEDs on the bottom panel of the RC4030E Gateway are visible. Because the LEDs are helpful troubleshooting aids, they should not be hidden by cables or other objects. Leave enough room to easily attach and remove the communication and power cables connected to the ports on the RC4030E Gateway’s bottom panel. Leave enough room to access the DIAG port for future upgrades. RC4030E Gateway User’s Guide
5-1
Page 78
SECTION 5
"
Installation
Vertical Mount Use the mounting bracket (P/N 699-612-002) provided with the RC4030E Gateway to mount it on a wall or post (Figure 5-1). Because the RC4030E Gateway does not require a clear line of site to the wireless stations, it can be mounted at any height. You can place the power supply on the mounting bracket behind the RC4030E Gateway. Use the appropriate hardware to attach the mounting bracket to the wall or post.
3 2 1
4
1. 2. 3. 4.
Mounting bracket (front view) RC4030E Gateway Mounting bracket (side view) NC3100 Power Supply
Figure 5-1 Vertical Mount
5-2
RC4030E Gateway User’s Guide
Page 79
SECTION 5
"
Installation
Horizontal Mount You can place the RC4030E Gateway on a table or shelf. Place the four self-adhesive rubber feet provided with the gateway on the back panel (Figure 5-2). The feet keep the gateway from slipping out of place. The LEDs on the bottom panel of the gateway are helpful troubleshooting aids. They should not be hidden by cables or other objects. 1
2
1. RC4030E Gateway 2. NC3100 Power Supply
Figure 5-2 Horizontal Mount
10BASE2 Ethernet The RC4030E Gateway can be wired to the end or middle of 10BASE2 cable. " NOTE:
The cable length between each network device on 10BASE2 must be at least 1.64 feet (.5 meters).
End of Segment Refer to Figure 5-3 and the procedure following it.
RC4030E Gateway User’s Guide
5-3
Page 80
SECTION 5
"
Installation
PWR STAT
NET
HOST
RF
DIAG SWITCHES
ETHERNET INPUT
1
12
1
4
1. 2. 3. 4.
NET BNC
3
2
NC3100 Power Supply, circular plug 10BASE2 cable T-connector Cable terminator
Figure 5-3 Wiring RC4030E Gateway to End of 10BASE2 " NOTE:
The 10BASE2 port is rugged. However, it can be damaged if it is forced to mate to the T-connector at an odd angle or if it is not properly aligned. Therefore, care should be taken when connecting the T-connector to the 10BASE2 port on the RC4030E Gateway.
1. Plug the T-connector (P/N 311-579-301) into the BNC port. 2. Plug one end of the Ethernet coaxial cable into an open end of the T-connector. Align the notches in the cable end with the posts on the T-connector, push the cable in, and twist one-quarter turn. 3. Plug the cable terminator (P/N 311-579-401) into the other open end of the T-connector. 4. Plug the circular plug on the power supply cable into the INPUT port, and tighten the threaded collar.
5-4
RC4030E Gateway User’s Guide