Page 61
SECTION 4
"
Configuration
The default is 0.0.0.0, which disables the ability to exchange TCP/IP traffic with another subnet or network. A router that connects subnet 1 to subnet 2 might have the address 172.16.8.1 on subnet 1 and 172.16.16.1 on subnet 2. A host with IP address 172.16.16.5 would specify an IP router address of 172.16.16.1 to reach host 172.16.8.10. IP routers are usually configured so a computer only needs to know one router’s address. This is true even if several routers on the segment connect to several other segments. If you are using DHCP to obtain an IP router address, and the DHCP server specifies a default IP router, the DHCP server specification overrides the setting for IP Router.
IP Frame Type IP Frame Type sets the type of frame containing IP traffic: DIX 802.3
Setting
Description
DIX (default)
Sets Ethernet type to DIX (Ethernet 2.0) for IP frames.
802.3
Sets Ethernet type to 802.3 with a SNAP header for IP frames. Select 802.3 if other network computers use SNAP encapsulation for IP frames.
DHCP DHCP provides a way for this RC4030E Gateway (the client) to obtain IP addresses from a DHCP server on the network.
RC4030E Gateway User’s Guide
4-29
Page 62
SECTION 4
"
Configuration
Settings for DHCP are: Enabled Enabled, if IP address is zero Disabled
Setting
Description
Enabled
Instructs DHCP to obtain the IP address, subnet mask, and (optional) default IP router address when the RC4030E Gateway reboots.
Enabled, if IP address is zero (default)
Retrieves IP addresses for the RC4030E Gateway, subnet mask, and default router, and the lease expiration time, from the DHCP server. The RC4030E Gateway ignores other configuration options. Note that if you enable DHCP, you must set IP Address to 0.0.0.0. Disables DHCP. You must manually set the IP addresses before the TCP/IP stack is enabled.
Disabled
The RC4030E Gateway responds only to address offers from DHCP or Bootp servers. In either case the server is specified in the DHCP server name field.
DHCP Server Name The prompt for the DHCP server name is: Range is: 31 chars
4-30
RC4030E Gateway User’s Guide
Page 63
SECTION 4
"
Configuration
The RC4030E Gateway responds only to the named server. The default server name is “Norand DHCP Server.” This name prevents the RC4030E Gateway from inadvertently obtaining an IP configuration from existing servers on the network. If the DHCP server name is configured with a null string (“”), the RC4030E Gateway responds to offers from any server. The class identifier string for the RC4030E Gateway is “Norand Gateway.” Servers use this string to identify the RC4030E Gateway.
Bootp Operation The RC4030E Gateway can also accept addresses from a Bootp server identified in the DHCP server name field. An address offer from a Bootp server is treated as if it were an infinite lease from a DHCP server.
Networks With DHCP and Bootp Servers If the DHCP server name is configured as “”, the RC4030E Gateway responds to either DHCP or Bootp servers. The RC4030E Gateway gives preference to DHCP offers. If a Bootp reply arrives at the RC4030E Gateway before any DHCP offers are received, the gateway waits an additional 4 seconds for a DHCP offer before responding. If a DHCP offer is received within the 4-second period, the Bootp reply is ignored and the DHCP offer is accepted.
Handshaking When the RC4030E Gateway responds to a DHCP or Bootp server, it broadcasts a single ARP request to the address offered. If no ARP response is received within 3 seconds, the RC4030E Gateway assumes the IP address is unique and completes the negotiation for that address. If an ARP reply is received before the timeout, the RC4030E Gateway assumes the address is a duplicate and declines the offer.
RC4030E Gateway User’s Guide
4-31
Page 64
SECTION 4
"
Configuration
Infinite Leases A DHCP server may be configured to grant an infinite lease to the RC4030E Gateway. A Bootp grant is always treated as an infinite lease. The RC4030E Gateway stores the IP address, subnet mask, and default router in the EEPROM configuration register and disables DHCP. These settings are maintained if the RC4030E Gateway is powered off or rebooted through the ROM command monitor. To restore DHCP client operation, reconfigure the IP address to 0.0.0.0. " NOTE:
DHCP is documented in RFCs 1533, 1534, and 1541. Bootp is documented in RFC 951.
Auto ARP Minutes The RC4030E Gateway periodically sends an unsolicited ARP response so routers can update their routing tables. The response enables a network management platform to learn about the RC4030E Gateway on the network by querying routers. Auto ARP Minutes is the number of minutes between periodic ARP requests. The prompt is: Range is: 0..120
The default is 5 minutes. A setting of 0 disables Auto ARP Minutes. If the default router’s address is 0, the ARP request is sent to the IP address of this RC4030E Gateway. Without the Auto ARP Minutes option, an RC4030E Gateway might not use its IP address for extended periods of time and expire from the router’s ARP table.
4-32
RC4030E Gateway User’s Guide
Page 65
SECTION 4
"
Configuration
Auto ARP Minutes enhances the discovery of the network architecture by network management tools, such as OpenView by Hewlett-Packard. The network management tool queries IP router ARP tables to locate the active IP addresses for the subnet. IP addresses for RC4030E Gateways should not be allowed to expire. The network management program would then need to ping all potential addresses on a subnet to locate active IP addresses, or require the user to enter a list.
Security Options Use [Security] to set these passwords: Password Service Password
“************” <Enabled>
Password This option is the top-level password you need to access the configuration menus. The prompt is: Range is: 16 chars
Enter 16 or fewer alphanumeric characters for this password. It is case insensitive and can be any combination of letters, numbers, and symbols. For security, the password appears as asterisks on the screen.
RC4030E Gateway User’s Guide
4-33
Page 66
SECTION 4
"
Configuration
Service Password Intermec maintains a service password so its Customer Response Center can configure this RC4030E Gateway if necessary. For example, if you forget what the configuration menus’ top-level password is, the Customer Response Center can access the menus through the service password. By default, the Service Password is enabled. If setting a service password violates your security guidelines, you can disable it. If it is already disabled and you forget the top-level password, you may need to send this RC4030E Gateway to a Service Center to be reconfigured. Contact the Customer Response Center for more information about the service password. See the Preface for contact information.
Program Part Numbers Following are program part numbers. The software is a combination of the 3270, 5250, and NORAND Native programs. Description
Contents
P/N
RCCOMBO FLASH
FLASH memory RCCOMBO program Disk holder
209-215-001
RCCOMBO kit
RCCOMBO program Disk holder RCCOMBO program
215-534-001
Media
4-34
RC4030E Gateway User’s Guide
210-693-001
Page 67
SECTION 4
Configuration
"
Creating a Web Browser Session " NOTE:
The RC4030E Gateway’s configuration menus are designed for HTML Level 2.0 or higher.
Before you can configure the RC4030E Gateway through a Web browser, you must connect the gateway to the Ethernet cable. (See Section 5, “Installing the Gateway,” for help.) You must also perform initial configuration through the DIAG port to set an IP address or DHCP server name. You should also configure a subnet mask and IP router address. The gateway must go through its boot sequence before you can configure it through the browser. If you reboot it while you configuring it through the browser, the session terminates. You can create a new session after the gateway reboots. To configure the RC4030E Gateway through a Web browser, see Figure 4-6 and the procedure following it.
HTTP 1
2
1. Platform with Web browser 2. RC4030E Gateway
Figure 4-6 Web Browser Session
RC4030E Gateway User’s Guide
4-35
Page 68
SECTION 4
"
Configuration
1. Ensure the RC4030E Gateway is connected to the Ethernet cable and has an assigned IP address. 2. Ensure the Web browser is installed on the platform. 3. Start the browser application. 4. Enter the RC4030E Gateway’s IP address in the browser’s Uniform Resource Locator (URL) field. For example: http://192.168.17.10 After you enter the correct IP address, the Enter Network Password screen appears: Enter Network Password Please enter your authentication information. Resource:
(resource number)
User name:
(resource number)
Password:
*******
OK Cancel
Save this password in your password list.
5. Enter the user name and password. Refer to the following chart for help.
4-36
RC4030E Gateway User’s Guide
Page 69
SECTION 4
Configuration
Setting
Description
Resource
A number assigned to this session. The number changes every time you access the Enter Network Password screen. The Resource number. For example, if the Resource number is 3550, the user name is 3550.
User name
" NOTE:
"
Password
Configuration menus’ top-level password. The default password is CR52401 (case insensitive). For security, the password appears as asterisks on the screen.
Save this password in your password list
If you check this option, the browser saves the password. You do not need to select this option because the Resource number changes every time you access this screen.
Only one computer at a time can access the configuration menus. If you unexpectedly receive a request for the user name and password, another user may be trying to view or modify the configuration through Telnet or the DIAG port. If a different computer tries to start another Web browser session, it is refused until the current session logs out.
Following is the initial screen that appears after you enter the correct user name and password. Configure the RC4030E Gateway by following the directions provided on this screen and the help screens. In addition, this user guide’s Index lists the page numbers for all menu options.
RC4030E Gateway User’s Guide
4-37
Page 70
SECTION 4
"
Configuration
Gateway Configuration Configuration Menus Review/write Changes F Logout
F
F
F
Reboot
Security Once you’ve successfully entered the user name and password into your browser, you are authorized to access the configuration. If five (5) minutes elapses without configuration activity, you will become unauthorized again. Only one computer at a time is allowed to be authorized for access to the configuration menus. If you unexpectedly receive a request for user name and password, it’s possible that another user is currently attempting to view or modify the configuration via telnet or the serial port. An attempt to start another HTTP session from another computer will be refused until this session has been logged out.
How to use the Configuration Menu 1. Select Review/write changes to see the existing changes from the defaults. Optionally select an Undo option to remove changes. 2. Locate and change configuration items by navigating in the Configuration Menu. 3. Select the Submit Changes button to submit the changes on each form. 4. Repeat the above steps until all changes have been submitted. 5. Select Review/write changes and review the changes you have made. 6. Select Commit to write the changes. Note: Some early browser versions can’t be convinced by the server to always get a fresh copy of a document that was previously fetched. This might cause old and misleading information to be displayed. Updating the browser, pressing the reload button, or disabling the browser’s cache may be helpful. Copyright E 1996-1998 Intermec Technologies Corporation. All rights reserved.
4-38
RC4030E Gateway User’s Guide