Page 51

SECTION 4

"

Configuration

[Sync Parms] Use [Sync Parms] to set options for the 3270, 5294, or 5394 host type. Options and their default settings are: Type Baud Rate NRZI Max Frame Host Timeout Mirroring Auto Reconnect Term Timeout XID SDLC Address.AD0 [SDLC Address]

" NOTE:

<RS232> <External> <Disabled> <256> 0 <Disabled> <Disabled> 0 0.0.0.0 1

The XID and SDLC Address.AD0 options appear if the host type is 3270. The [SDLC Address] option appears if the host type is 5294 or 5394.

Type Use Type to set the type of electrical connection between the RC4030E Gateway and the host. Settings are: RS232 V.35

The default is RS232.

Baud Rate Baud Rate is the speed setting for the serial communications port. Settings are External (default), 1200, 2400, 4800, 9600, 19200, 38400, 56000, and 64000.

RC4030E Gateway User’s Guide

4-19

Page 52

SECTION 4

"

Configuration

NRZI NRZI is “nonreturn to zero inverted,” a signaling mode for V.35. The setting must match the host’s setting: Enabled Disabled

Setting

Description

Enabled

Signaling is NRZI.

Disabled (default)

Signaling is NRZ.

Max Frame Max Frame is the number of octets in the largest SDLC frame: 256 512

The default is 256. The 5294 Control Unit can support a frame size of 256 bytes of data. The 5394 Control Unit can support a frame size of 512 bytes of data.

Host Timeout Host Timeout is the number of seconds of host inactivity before the host is considered down. The prompt is: Range is: 0..255

The default of zero means the RC4030E Gateway never times out the host. Ten or more seconds is recommended. Do not set Host Timeout to zero if the wireless station is configured to communicate with up to three hosts through the wireless station’s Advanced Setup firmware option.

4-20

RC4030E Gateway User’s Guide

Page 53

SECTION 4

"

Configuration

After the host timeout value has been exceeded, the wireless station displays “Host is Down.” The user can then reboot the wireless station. The RC4030E Gateway tries to connect with the next host defined for the wireless station.

Mirroring " NOTE:

Mirroring is supported only on the SST (Spread Spectrum Transmission) RC4030E Gateway. Mirroring is not supported on the RC4030E Gateway on the open wireless LAN.

Mirroring optimizes the data sent to the wireless stations by keeping a screen image for each wireless station. Only the changes from one image to the next are sent to the wireless station. Settings are: Enabled Disabled

Setting

Description

Enabled

RC4030E Gateway optimizes data sent to the wireless stations. This shortens communication time because only the screen changes are updated.

Disabled (default)

RC4030E Gateway does not optimize data.

Auto Reconnect " NOTE:

Auto Reconnect is supported only on the SST (Spread Spectrum Transmission) RC4030E Gateway. Auto Reconnect is not supported on the RC4030E Gateway on the open wireless LAN.

Auto Reconnect allows reconnection to the host. Settings are: Enabled Disabled

RC4030E Gateway User’s Guide

4-21

Page 54

SECTION 4

"

Configuration

Setting

Description

Enabled

All wireless stations communicating with this RC4030E Gateway return to the SNA session they were at before they were turned off. This avoids logging back onto the SNA host.

Disabled (disabled)

User must log onto the host when they turn the wireless station on. For security, Auto Reconnect should be set to Disabled. Or, the user can log off the wireless station before turning it off.

Term Timeout Term Timeout indicates how long a wireless station may remain idle before being disconnected. The prompt is: Range is: 0..255

The default is zero.

XID XID is the exchange ID that applies only to 3270 communications. The prompt is: Range is: 4 hex pairs

The default is 0.0.0.0. The setting must match the host’s setting.

4-22

RC4030E Gateway User’s Guide

Page 55

SECTION 4

"

Configuration

SDLC Address.AD0 SDLC Address.AD0 is the address table for 3270 SNA/SDLC communications. The prompt is: Range is: 1 hex pairs

The default is 1 hex pair. Set the option according to the SDLC address of the host.

[SDLC Address] [SDLC Address] is the address table for 5250 SNA/SDLC communications. The settings for [SDLC Address] depend on the host type (5294 or 5394). 5294 Host Type Settings for the 5294 host type are as follows: AD0 1 AD1 0 AD2 0 AD3 0 AD4 0 AD5 0 AD6 0 AD7 0

The RC4030E Gateway can emulate eight multidrop IBM 5294 Control Units, which works best for IBM System/36 and System/38 hosts. The RC4030E Gateway supports 64 logical units (LUs) which correspond with wireless station network addresses 0 to 63.

RC4030E Gateway User’s Guide

4-23

Page 56

SECTION 4

"

Configuration

Figure 4-4 shows how the RC4030E Gateway emulates eight 5294 Control Units with 8 logical units (LUs) each. The LUs are located at SDLC addresses 1 through 8. This provides up to 64 LUs.

RC4030E Gateway 5294

5294

SDLC address #1 (up to 8 LUs) (wireless station addresses 0--7)

SDLC address #2 (up to 8 LUs) (wireless station addresses 8--15)

5294

5294

SDLC address #3 (up to 8 LUs) (wireless station addresses 16--23)

SDLC address #4 (up to 8 LUs) (wireless station addresses 24--31)

5294

5294

SDLC address #5 (up to 8 LUs) (wireless station addresses 32--39)

SDLC address #6 (up to 8 LUs) (wireless station addresses 40--47)

5294

5294

SDLC address #7 (up to 8 LUs) (wireless station addresses 48--55)

SDLC address #8 (up to 8 LUs) (wireless station addresses 56--63)

Figure 4-4 RC4030E Gateway Emulating 5294 Control Unit for System/36 or System/38 Host

4-24

RC4030E Gateway User’s Guide

Page 57

SECTION 4

"

Configuration

5394 Host Type Settings for the 5394 host type are as follows: AD0 1 AD1 0 AD2 0 AD3 0

The RC4030E Gateway can emulate four multidrop IBM 5394 Control Units, which works best for IBM AS/400 hosts. The RC4030E Gateway supports 64 LUs which correspond with wireless station network addresses 0 to 63. When emulating four 5394 Control Units, each logical RC4030E Gateway handles 16 LUs. A group of 16 LUs is linked to each SDLC address, numbers 1 through 4. Figure 4-5 shows a logical representation of four 5394 Control Units emulated by the RC4030E Gateway. RC4030E Gateway 5394

5394

SDLC address #1 (up to 16 LUs) (wireless station addresses 00--15) 5394

SDLC address #2 (up to 16 LUs) (wireless station addresses 16--31)

5394

SDLC address #3 (up to 16 LUs) (wireless station addresses 32--47)

SDLC address #4 (up to 16 LUs) (wireless station addresses 48--63)

Figure 4-5 RC4030E Gateway Emulating 5394 Control Unit for AS/400 Host

RC4030E Gateway User’s Guide

4-25

Page 58

SECTION 4

"

Configuration

TCP/IP Options Use [Tcpip] to set options necessary for communications with this RC4030E Gateway, such as IP addresses. Addresses are required for remote setup or SNMP network management. Options and their default settings are: IP Address IP Subnet Mask IP Router IP Frame Type DHCP DHCP Server Name Auto ARP Minutes

0.0.0.0 255.255.255.0 0.0.0.0 <DIX> <Enabled, if IP address is zero> “Norand DHCP Server” 5

IP Address IP Address is the unique address locally assigned to this RC4030E Gateway. The prompt is: Range is: 4 nums 0..255

The default is 0.0.0.0, which disables the ability to use TCP/IP. Following are suggestions for setting the address: If you are installing this RC4030E Gateway on an existing Ethernet segment, you should allocate the IP address from the same pool as the existing computers on the segment. " If you are installing this RC4030E Gateway on a new Ethernet segment that is not going to connect to the Internet, try using this Class B address: 172.16.h.h

"

4-26

RC4030E Gateway User’s Guide

Page 59

SECTION 4

"

Configuration

The host number is “h.h.” This Class B network address is reserved by the numbering authority for a company’s internal use. If the Class B address appears on the Internet, routers drop the data. Note the following: If the IP address is 0.0.0.0 and DHCP is enabled, this IP address is obtained through DHCP. " If the IP address is 0.0.0.0 and DHCP is disabled, TCP/IP access to this RC4030E Gateway is disabled. A discussion of DHCP starts on page 4-29. "

IP Subnet Mask IP subnets partition traffic and are connected by routers. The subnet mask indicates how many bits of the IP address represent a network number and how many indicate a host number. The prompt is: Range is: 4 nums 0..255

The default is 255.255.255.0. Following are suggestions for setting the subnet mask: If you are installing this RC4030E Gateway on an existing Ethernet segment, the subnet mask should match the other computers on the segment. " If you are using the 172.16.h.h address suggested for IP Address, you may want to use a subnet mask of 255.255.248.0. This mask provides the network 172.16 with 30 subnets of 2046 computers each. "

RC4030E Gateway User’s Guide

4-27

Page 60

SECTION 4

"

Configuration

The IP address breakdown is: 16 bits of network address. " 5 bits of subnet address. Do not use all 0’s or all 1’s. " 11 bits of host address. Do not use all 0’s or all 1’s. The following chart lists IP addresses when the submask is 255.255.248.0. "

Subnet 1 2 3 . . . 30

First Address 172.16.8.1 172.16.16.1 172.16.24.1

Last Address 172.16.15.254 172.16.23.254 172.16.31.254

172.16.240.1

172.16.247.254

If you are using DHCP to obtain an IP subnet mask for this RC4030E Gateway, the subnet mask obtained from DHCP overrides the setting for the IP Subnet Mask option.

IP Router " NOTE:

The IP address of the router is required only if this RC4030E Gateway will communicate with devices on the other side of the router.

IP Router identifies the default router used to forward data frames to addresses on another subnet. The prompt is: Range is: 4 nums 0..255

4-28