Page 81
SECTION 5
"
Installation
5. Plug the power supply into an ac outlet. The LEDs should do the following: " "
"
PWR LED comes ON. STAT LED flashes three times within about 20 seconds. ETHERNET LED flashes two 1-second dashes (for Ethernet Version 2.0).
Middle of Segment Refer to Figure 5-4 and the procedure following it.
PWR STAT
NET
HOST
RF
DIAG SWITCHES
ETHERNET INPUT
1
12
1
NET BNC
3
2
1. NC3100 Power Supply, circular plug 2. 10BASE2 cable 3. T-connector
Figure 5-4 Wiring RC4030E Gateway to Middle of 10BASE2 " NOTE:
The 10BASE2 port is rugged. However, it can be damaged if it is forced to mate to the T-connector at an odd angle or if it is not properly aligned. Therefore, care should be taken when connecting the T-connector to the 10BASE2 port on the RC4030E Gateway.
RC4030E Gateway User’s Guide
5-5
Page 82
SECTION 5
"
Installation
1. Plug the T-connector (P/N 311-579-301) into the BNC port. 2. Plug one end of the Ethernet coaxial cable into an open end of the T-connector. Align the notches in the cable end with the posts on the T-connector, push the cable in, and twist about one-quarter turn. 3. Plug the end of another Ethernet coaxial cable segment into the other open end of the T-connector. 4. Plug the circular plug on the power supply cable into the INPUT port, and tighten the threaded collar. 5. Plug the power supply into an ac outlet. The LEDs should do the following: " PWR LED comes ON. " STAT LED flashes three times within about 20 seconds. " ETHERNET LED flashes two 1-second dashes (for Ethernet Version 2.0). If your RC4030E Gateway’s LEDs are not flashing correctly see Section 6, “Troubleshooting.”
10BASE-T Ethernet Refer to Figure 5-5 and the procedure following it.
5-6
RC4030E Gateway User’s Guide
Page 83
SECTION 5
PWR STAT
NET
"
Installation
HOST
RF
DIAG SWITCHES
ETHERNET INPUT
1
NET
12
BNC
1 4
3
2
5
1. 2. 3. 4. 5.
NC3100 Power Supply, circular plug T-connector 10BASE2 cable 10BASE2 to 10BASE-T converter 10BASE-T hub
Figure 5-5 Wiring RC4030E Gateway to 10BASE-T
1. Plug one end of the coaxial cable into the designated port on the converter. Align the notches in the cable end with the posts on the T-connector, push the cable in, and twist about one-quarter turn. 2. Plug the other end of the coaxial cable into an open end of the T-connector. 3. Plug the circular plug on the power supply cable into the INPUT port, and tighten the threaded collar.
RC4030E Gateway User’s Guide
5-7
Page 84
SECTION 5
"
Installation
4. Plug the power supply into an ac outlet. The LEDs should do the following: " PWR LED comes ON. " STAT LED flashes three times within about 20 seconds. " ETHERNET LED flashes two 1-second dashes (for Ethernet Version 2.0). If your RC4030E Gateway’s LEDs are not flashing correctly see Section 6, “Troubleshooting.” " NOTE:
Unshielded, 10BASE-T twisted-pair cable gets its electrical characteristics from its twisted form. When installing 10BASE-T, use twisted pair cable and keep the pairs twisted (about one twist per inch). Otherwise, 10BASE-T is not affected by the distortions that affect coaxial cable.
Connecting to the Host The RC4030E Gateway communicates with the host computer through the gateway’s HOST port. To connect the gateway to the host refer to Figure 5-6 and the following procedure. " NOTE:
5-8
The host cable you use depends on whether the interface is RS-232 or V.35, and whether the host has a male or female port. Cables and pin-outs are listed in Appendix A, “Cable and Port Pin-Outs.”
RC4030E Gateway User’s Guide
Page 85
SECTION 5
Installation
"
2 PWR STAT
NET
HOST
RF
DIAG SWITCHES
ETHERNET INPUT
1
1
12
NET BNC
3
1. NC3100 Power Supply, circular plug 2. HOST port 3. Host cable
Figure 5-6 Connecting RC4030E Gateway to Host
1. Plug the 25-pin male connector on the host cable into the 25-pin female HOST port on the bottom panel of the RC4030E Gateway. 2. Plug the connector on the other end of the host cable into the designated port on the host computer.
RC4030E Gateway User’s Guide
5-9
Page 86
SECTION 5
"
Installation
Verifying Operation The LEDs on the bottom panel of the RC4030E Gateway continuously indicate the gateway’s operating status after it is installed. Figure 2-3 on page 2-5 shows where the LEDs are located. LEDs that flash do so in one of two modes: "
"
Normal mode: LED flashes at a random rate with varied intensity to indicate the activity level during normal operation. Error mode: LED flashes at a constant rate and intensity to indicate an error.
PWR (Power) The green PWR LED is ON when the RC4030E Gateway is receiving power. If the LED is OFF, make sure the power supply is plugged into a “live” 120 V ac outlet and the power supply cable is firmly inserted into the INPUT port on the RC4030E Gateway.
STAT (Status) The yellow STAT LED is normally OFF. It is ON if the RC4030E Gateway fails. Usually, within about 20 seconds of resetting or power connection, the LED flashes three times to indicate that initialization is complete and the RC4030E Gateway is operational.
5-10
RC4030E Gateway User’s Guide
Page 87
SECTION 5
"
Installation
NET (Network) The green NET LED is not used on the RC4030E Gateway. It should always be OFF.
RF (Radio Frequency) The yellow RF LED is not used on the RC4030E Gateway. It should always be OFF.
ETHERNET (Ethernet Connection) The green ETHERNET LED is ON when the RC4030E Gateway is directly connected to the Ethernet LAN. During normal operation, the ETHERNET LED flashes for one second when the gateway receives or sends an Ethernet packet. Frequent packets keep the ETHERNET LED turned ON continuously. If the ETHERNET LED is constantly flashing there is a physical problem with the network. See Section 6, “Troubleshooting,” for help with solving the problem.
RC4030E Gateway User’s Guide
5-11
Page 88
SECTION 5
5-12
"
Installation
RC4030E Gateway User’s Guide
Page 89
Section 6
Troubleshooting "
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
This section describes how to use network analysis tools and the RC4030E Gateway’s LEDs to troubleshoot problems.
Network Analysis Tools The RC4030E Gateway meets all Ethernet specifications. If you are familiar with how to troubleshoot an Ethernet LAN, you can use standard network analysis tools to troubleshoot the gateway. If an external system is available to send a standard Ethernet Version 2 type loopback packet (type = 0x9000), the RC4030E Gateway responds if it is operating properly.
LEDs The LEDs on the bottom panel of the RC4030E Gateway continuously show the device’s status. The LEDs also help you diagnose problems. After the gateway powers up and completes its self-test, the LEDs indicate whether the device is operating properly.
RC4030E Gateway User’s Guide
6-1
Page 90
SECTION 6 "
Troubleshooting
If the gateway is operating properly on power-up, the LEDs do the following during the self-test. LED Activity
Meaning
PWR LED comes ON
RC4030E Gateway is receiving power.
STAT LED flashes three times within about 20 seconds
Initialization is complete and the gateway is operational.
ETHERNET LED flashes two 1-second dashes (Ethernet 2.0) or three 1-second dashes (802.3)
Ethernet port is enabled.
If the LEDs are not operating properly at power-up, run the self-test again to see if the problem repeats itself. To run the self-test, reset the RC4030E Gateway by unplugging its ac power cord from the outlet and then plugging it back into the outlet. If resetting the RC4030E Gateway does not help, see Table 6-1 for assistance.
6-2