Page 31
SECTION 3
"
Preparation
Assembled dc power extension cables are available from Intermec in lengths of 6, 12, and 25 feet. The following chart lists part numbers. Extension Cable Length
P/N
6 feet
216-886-001
12 feet
216-886-002
25 feet
216-886-003
Another outlet should be available near the RC4030E Gateway for LAN test equipment if troubleshooting is necessary.
Hardware You can mount the RC4030E Gateway vertically on a wall or post, or horizontally on a tabletop. If mounting the gateway vertically, determine what hardware is needed. Different surfaces (for example, drywall, wood, concrete block) require different types of screws. For this reason, Intermec provides only a mounting bracket with the gateway. For an RC4030E Gateway mounted vertically, the power supply is usually placed on the gateway’s wall mounting bracket. If this is not feasible you may want to install an extra mounting bracket to hold the power supply.
Cabling Ensure that your site’s coaxial or twisted pair cabling will be able to reach the RC4030E Gateway after it is mounted vertically or horizontally.
RC4030E Gateway User’s Guide
3-7
Page 32
SECTION 3
"
Preparation
Specifications Physical Dimension
Measurement
Length
12.0 in (30.48 cm)
Width
6.4 in (16.25 cm)
Height
2.5 in (6.35 cm)
Weight
4.30 lbs (1.95 kg)
Environmental Parameter
Value
Operating temperature
--22 to 122 dF (--30 to 50 dC)
Storage temperature Humidity
--22 to 140 dF (--30 to 60 dC) 5 to 95 percent noncondensing
ESD protection
±8 kV, per IEC 801-2(E)-1991
Package vibration
6g rms, quasi-random
Power Supply (United States)
3-8
Parameter
Value
Input voltages
120 V ac
Output voltages
+9.0 V dc, +13.5 V dc
Power consumption
30 watts
Approval
UL/CSA
RC4030E Gateway User’s Guide
Page 33
Section 4
Configuration "
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
This section describes how to do the following: Create a local DIAG port, Telnet, or Web browser session with the RC4030E Gateway " Configure the gateway’s system software with your site’s host characteristics and communication requirements " Upload a new version of system software " Check the FLASH and ROM versions You can configure the RC4030E Gateway through its DIAG port, or remotely through Telnet or a Web browser. The following chart shows the sessions you can use to do other tasks. "
Task
DIAG Port
Telnet
Browser
Change configuration passwords Modify the configuration
Ö
Ö
Ö
Ö
Ö
Ö
Upgrade FLASH
Ö
Check the FLASH version
Ö
Access ROM
Ö
Check the ROM version
Ö
Use online help
Ö
Ö
Ö
RC4030E Gateway User’s Guide
4-1
Page 34
SECTION 4
"
Configuration
Only one type of session can be running at a time. For example, if someone starts a Telnet session while someone else is configuring the RC4030E Gateway through its DIAG port, the configuration through the DIAG port will terminate.
Creating a Local DIAG Port Session To configure the RC4030E Gateway through its DIAG port, refer to Figure 4-1 and the procedure following it.
1. PC with VT100 terminal emulation program (such as PROCOMM PLUS) 2. Cable P/N 216-841-00X for 25-pin COM port; P/N 216-842-00X for 9-pin COM port 3. RC4030E Gateway DIAG port
Figure 4-1 Local Session
4-2
RC4030E Gateway User’s Guide
Page 35
SECTION 4
"
Configuration
1. Ensure the VT100 terminal emulation program is installed on the PC. 2. Turn the PC off and unplug the RC4030E Gateway’s power supply from the outlet. 3. Plug the 9-pin male connector on the cable into the female DIAG port on the bottom panel of the gateway. 4. Plug the 9-pin or 25-pin female connector on the other end of the cable into the designated COM port on the PC. 5. Turn the PC on and start the terminal emulation program. Communication parameters should be set to: 19200, 8N1, half duplex, incoming CR to CR/LF 6. To use the configuration menus, see the following instructions. To upload a new version of software, see page 4-39. To check the current FLASH and ROM versions, see page 4-43. To use the configuration menus, do the following: 1. Make sure the command interpreter switch (switch #11) is in the OFF (open) position. (OFF is the factory-set default.) 2. With the terminal emulation program running on the PC, power cycle the RC4030E Gateway by plugging its power supply into an outlet. When you power cycle the gateway, it reboots into the configuration program, where the menus are located. 3. See “Configuring the RC4030E Gateway” on page 4-7.
RC4030E Gateway User’s Guide
4-3
Page 36
SECTION 4
"
Configuration
Creating a Telnet Session Before you can configure the RC4030E Gateway through Telnet, you must connect the gateway to the Ethernet cable. (See Section 5, “Installation,” for help.) You must also perform initial configuration through the DIAG port to set an IP address or DHCP server name. You should also configure a subnet mask and IP router address. The RC4030E Gateway must go through its boot sequence before you can create a Telnet session. If you reboot it while in a session, the session terminates. You can create a new session after the gateway reboots. To create a Telnet session, see Figure 4-2 and the procedure following it. Ethernet LAN
Telnet 1
2
1. PC or workstation with Telnet VT emulator (TNVT) 2. RC4030E Gateway
Figure 4-2 Telnet Session
1. Ensure the RC4030E Gateway is connected to the Ethernet cable and has an assigned IP address. 2. Ensure the PC or workstation has an installed and configured Ethernet interface card.
4-4
RC4030E Gateway User’s Guide
Page 37
SECTION 4
"
Configuration
3. Ensure the Telnet VT emulator is installed on the PC or workstation. 4. Open a new Telnet session on the PC or workstation. 5. Enter the RC4030E Gateway’s IP address in the host name or IP address field. 6. See “Configuring the RC4030E Gateway,” page 4-7.
Default and Site Settings Gateway Options Options Name Gateway.Compression Host Type [Async Parms] Baud Rate Stop Bits Parity Data Bits Host Timeout Address Type Enhanced R Polling Multiple Buffering Full Duplex
Default HOST Disabled Async
Site Setting
19200 1 None 8 0 Normal Disabled Disabled Disabled
RC4030E Gateway User’s Guide
4-5
Page 38
SECTION 4
"
Configuration
TCP/IP Options Option IP Address IP Subnet Mask IP Router IP Frame Type DHCP DHCP Server Name Auto ARP Minutes
Default 0.0.0.0 255.255.255.0 0.0.0.0 DIX Enabled, if IP Address is zero Norand DHCP Server 5
Site Setting
Security Options Option Password Service Password
Notes:
4-6
RC4030E Gateway User’s Guide
Default CR52401 Enabled
Site Setting
Page 39
SECTION 4
"
Configuration
Configuring the RC4030E Gateway When you connect to the RC4030E Gateway through its DIAG port or through a Telnet session, the configuration program’s password screen appears: Configuration of Gateway Copyright (c) 1995-1998 Intermec Technologies Corporation. All rights reserved. Portions copyright Epilogue Technology Corporation, 1988-1995.
IP: Gateway:
0.0.0.0 HOST
Password:
" NOTE:
A different screen appears when you create a session through a Web browser. See page 4-35 for information about Web browser sessions.
The password screen shows the current settings for the IP address and RC4030E Gateway host name. It also shows the prompt for the top-level password. Enter the password (case insensitive) to display the Main Menu. The default password is CR52401. " NOTE:
If you forget what the password is, you can access the RC4030E Gateway by connecting to its DIAG port (no modem) and power cycling it. When the PC displays this message: Rebooting Quickly press a key to perform configuration before startup
Press any key on the PC’s keyboard within the next 3 seconds to bypass the password screen and access the command screen. You can then view or change the password through the View command.
RC4030E Gateway User’s Guide
4-7
Page 40
SECTION 4
"
Configuration
Main Menu After you enter the top-level password, the Main Menu appears: Loading configuration from EEPROM Command View Clear Read Write Reboot Exit ?
Description View/modify the configuration Set the configuration to default values Read the configuration from EEPROM Write the configuration to EEPROM Restart using last written configuration Disconnect Display this help
>
The menu lists the commands you can use to do various tasks, described on the following pages. The screen also displays the command screen prompt ( > ). At the prompt, type the name of the command you want to perform and press [Enter]. (Commands are case insensitive.) The Main Menu redisplays when you enter an invalid command. The following chart describes how to use the commands.
4-8
Use
To
View
View or modify configuration program settings. See “Using the View Command” on page 4-9.
Clear
Reset the RC4030E Gateway’s configuration to the factory-set default settings, which start on page 4-5.
Read
Load the most recent configuration from EEPROM. The configuration that was written to EEPROM since the RC4030E Gateway was last rebooted becomes the new configuration.
RC4030E Gateway User’s Guide