Page 21

SECTION 2

"

Introduction

Switches The RC4030E Gateway’s switches are centrally located on the bottom panel (Figure 2-5).

PWR STAT

NET

HOST

RF

DIAG SWITCHES

ETHERNET INPUT

1

1

NET

12

BNC

1. Switches

Figure 2-5 Switches

Reset

4

Command Interpreter

3

Diagnostic Baud Rate *

2

Attach Priority *

1

Root Priority *

Switch Number

Ethernet Type *

Switch Name

LAN ID *

Figure 2-6 shows the switches in detail. In the figure, an asterisk (*) after the switch name indicates that the switch is not operational.

5

7

9

11

12

6

8

10

ON = Closed OFF = Open

OFF

Figure 2-6 Switches, Enlarged View

Page 2-8 describes the operational command interpreter and reset switches. RC4030E Gateway User’s Guide

2-7

Page 22

SECTION 2

"

Introduction

Command Interpreter (Switch 11) If the command interpreter switch is in the OFF (open) position when the RC4030E Gateway is power cycled, the gateway boots into the configuration program (where the system software parameters are located). If the switch is in the ON (closed) position when the gateway is power cycled, the gateway boots into ROM mode. For normal operation the switch must be in the OFF (open) position. Default = OFF Switch Number

11

ON = Closed OFF = Open

OFF

Reset (Switch 12) The reset switch power cycles the RC4030E Gateway. If this switch is ON (closed), the gateway will reset every five seconds. The switch must be OFF (open) for normal operation. Default = OFF Switch Number

12

ON = Closed OFF = Open

OFF

2-8

RC4030E Gateway User’s Guide

Page 23

SECTION 2

"

Introduction

Changing a Switch Setting To change a switch setting, use a long pointed object (such as a straightened paper clip) to press the rocker switch up or down. Do not use a pencil because the lead may break off inside the RC4030E Gateway. A new setting takes effect after the RC4030E Gateway powers up or is reset. Whenever you change a switch setting, you must power cycle or reset the RC4030E Gateway. To reset the gateway, do one of the following: "

"

Unplug the RC4030E Gateway’s power supply from the outlet and then plug it back into the outlet. Set switch 12 (reset) to ON for about 5 seconds (or until the LEDs flash).

RC4030E Gateway User’s Guide

2-9

Page 24

SECTION 2

2-10

"

Introduction

RC4030E Gateway User’s Guide

Page 25

Section 3

Preparation "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

This section discusses the following tasks: Preparing your site " Inspecting the shipment’s contents " Collecting the equipment you need " Assigning network addresses " Selecting the best location for the RC4030E Gateway These tasks should be completed before the RC4030E Gateway is wired to the Ethernet medium. "

Preparing Your Site To prepare your site, ensure that you have the appropriate type and length of Ethernet medium. Also ensure your Ethernet LAN is in place and operable. Intermec strongly recommends that Intermec or certified providers conduct a site survey to determine the ideal locations for all of your network components. A proper site survey requires special equipment and training. A site survey provides an installation recommendation that addresses various factors, which can affect the performance of your wireless LAN system.

RC4030E Gateway User’s Guide

3-1

Page 26

SECTION 3

"

Preparation

Inspecting the Shipment’s Contents Unpack the RC4030E Gateway and check your shipment for damage or missing parts. The shipment contains the RC4030E Gateway and the following items for the United States market (items are in kit P/N 225-537-001): " " " "

" NOTE:

NC3100 Power Supply Mounting bracket RC4030E Gateway User’s Guide Warranty card

The power supply is not included in the kit for the international market. The international kit’s part number is 225-537-002.

Inspect the RC4030E Gateway for physical damage that may have occurred during shipment or storage. If you need to return a part for repair, ship it to the nearest Customer Service Center. When an RC4030E Gateway must be returned, pack it in the original shipping carton if possible. Complete and return the Product Service Information card packaged with the gateway.

Collecting the Equipment Before you install the RC4030E Gateway, collect the equipment you will need so it will be close at hand.

Ethernet LAN Components The RC4030E Gateway is designed for direct connection to 10BASE2 Ethernet.

3-2

RC4030E Gateway User’s Guide

Page 27

SECTION 3

"

Preparation

10BASE2 Components 10BASE2 components include a T-connector and cable terminator. The 10BASE2 T-connector (Figure 3-1) attaches to the RC4030E Gateway’s 10BASE2 port, and connects the gateway to the middle or end of 10BASE2 cable.

Figure 3-1 T-connector

A cable terminator (Figure 3-2) attaches to the T-connector. It is required for an RC4030E Gateway connected to the end of 10BASE2 cable. The terminator properly terminates the network cable to maintain proper impedance. Proper termination is necessary for reliable network communications.

Figure 3-2 Cable Terminator

10BASE-T Component The 10BASE-T component is a cable that can extend up to 328 feet (100 meters) in length. The cable has an RJ45 plug at each end (Figure 3-3).

Figure 3-3 Cable With RJ45 Plugs RC4030E Gateway User’s Guide

3-3

Page 28

SECTION 3

"

Preparation

Host Computer Cable The cable you need to connect the RC4030E Gateway to the host depends on the type of host interface (RS-232 or V.35). Appendix A, “Cable and Port Pin-Outs,” lists host cables, their part numbers, and pin-outs.

Communication Equipment You can access the RC4030E Gateway’s system software configuration menus locally through its DIAG port, or remotely through a Telnet session or Web browser.

Local DIAG Port Access For local access, you need the following: "

"

"

Third-party communications software terminal emulation package with Y-modem capability (such as PROCOMM PLUS by DataStorm Technologies, Inc.). Install the program according to its user guide. PC (personal computer), which should meet the requirements outlined in the user guide for the terminal emulation program. Cables to connect the PC to the RC4030E Gateway’s DIAG port. The following chart lists cables. For This PC Port

Use Cable Part Number

9-pin

216-842-00X*

25-pin

216-841-00X*

* x = 6, 25, or 50 feet

3-4

RC4030E Gateway User’s Guide

Page 29

SECTION 3

"

Preparation

Telnet You need the following to access the configuration menus through a Telnet session: "

" "

PC or workstation with an installed and configured network interface card and a Telnet application. You can also use a host capable of acting as a Telnet client. Telnet VT emulator (TNVT) installed on the PC. IP address for the RC4030E Gateway. For more information about IP addresses, see Section 4, “Configuration.”

Web Browser The RC4030E Gateway’s configuration menus are designed for HTML Level 2.0 or higher. You need the following to access the configuration menus through a Web browser: " " "

Graphical browser application Internet or local network connection IP address for the RC4030E Gateway. For more information about IP addresses, see Section 4.

System Management Tools To manage the system through a network management platform, you need the platform (such as OpenView for Windows by Hewlett-Packard) installed on a network management station using SNMP. The station must meet the requirements outlined in the platform’s user guide.

RC4030E Gateway User’s Guide

3-5

Page 30

SECTION 3

"

Preparation

Selecting the Best Location The RC4030E Gateway does not have a radio module or antenna. Because it does not use radio transmissions to communicate with the wireless stations, it does not require a clear line of site to them. Therefore, Intermec strongly suggests that the RC4030E Gateway be located next to the host computer in a computer room. The cable from the RC4030E Gateway to the host is available in 6, 25, and 50-foot lengths.

Power Supply The RC4030E Gateway is powered by an NC3100 Power Supply, which has the following characteristics for the United States market: " " "

" NOTE:

Domestic 120 V ac 60 Hz power, UL and CSA approval Required filtration to meet FCC emissions requirements

A different NC3100 Power Supply is used in Europe and other areas having 230 V ac, 50 Hz power with TUV approval. Another type of NC3100 Power Supply is used in Japan and other areas having 100 V ac, 50 or 60 Hz power with MITI approval. Contact your Intermec representative for more information about power supplies for international markets.

The power supply must be located within 6 feet of the gateway and 6 1/2 feet of the power outlet. These distances ensure that the power supply’s cables will reach the gateway and outlet. If an outlet cannot be located within 6 feet of the gateway, the dc power cable can be extended. Because of the voltage drop in these cables the extension should not exceed 25 feet.

3-6

RC4030E Gateway User’s Guide