Page 121

APPENDIX B

"

Barcode Symbologies are identical with Code 39. Each character consists of nine modules arranged into three bars and three spaces. Code 93 uses 48 of the 56 possible combinations. One of these characters, represented by a square, is reserved for a start or stop character, four are used for control characters, and the remaining 43 data characters coincide with the Code 39 character set. An additional single module termination bar after the stop character concludes the final space. Code 93 is a variable length, continuous code that is not self-checking. Bar and space widths may be one, two, three, or four modules wide. Its structure uses edge-to-similar-edge decoding. This makes the bar code immune to uniform ink spread, which allows liberal bar width tolerances. Code 93 uses two check characters. Its supporters believe this makes it the highest density alphanumeric bar code. The dual check digit scheme provides for high data integrity. All substitution errors in a single character are detected for any message length. C128

C128 (Code 128) is one of the newest symbologies used by the retail and manufacturing industries. It was designed in response to the need for a compact alphanumeric bar code symbol that could encode complex product identification. The fundamental requirement called for a symbology capable of being printed by existing data processing printers (primarily dot-matrix printers) that produce daily, work-in-progress, job, and product traceability documents. The ability to print identification messages between 10 and 32 characters long, on existing forms and labels was deemed an important requirement. Code 128 uniquely addresses this need as the most compact, complete, alphanumeric symbology available. Additionally, the Code 128 design with geometric features, improves scanner read performance, does self-checking, and provides data message management function codes. Code 128 encodes the complete set of 128 ASCII characters without adding extra symbol elements. Code 128 contains a variable length symbology and the ability to link one message to another for composite message transRT1700 Radio Data Terminal User’s Guide

B-7

Page 122

APPENDIX B

"

Barcode Symbologies mission. Code 128, being a double-density field, provides two numeric values in a single character. Code 128 follows the general bar code format of quiet zone, start code, data, check digit, stop code, and quiet zone. An absolute minimum bar or space dimension of nine mils must be maintained (0.010 inch minimum nominal ± 0.001 inch tolerance). UCC/EAN-128 Shipping Container Labeling is a versatile tool that can be used to ease movement of products and information. The Shipping Container Labeling bar code can take any form and usually has meaning only within the company or facility where it is applied. Because this random data may be mistaken later for an industry standard code format, the UCC and EAN chose a symbology which can be uniquely identified from these other bar codes. This standard is designed for maximum flexibility, to cost-effectively handle the diversity of distribution in global markets. The UCC/EAN-128 Container Labeling specification calls for a FUNC1 to immediately follow the bar code’s start character. FUNC1 also follows any variable length application field. The specification also calls for the application to supply ]C1 for the symbology identification and the first FUNC1. The specification requires that the terminal send a <GS> (hex 1D) for subsequent FUNC1 codes in the bar code. Because <GS> is not compatible with terminal emulation data streams, the Uniform Code Council has been asked that the specification change be made to send the same three character sequence “]C1” to identify the embedded FUNC1 codes. This implementation should provide clean application coding by identifying the same sequences for the same scanned codes. If you enable the communication of NORANDR handled bar code types, the Shipping Container Label codes will be preceded with a J. These strings will be displayed on your terminal display. Your application may have to allow for strings longer than 48 characters (maximum length indicated in the specification). Actual length or lengths variance depends on the number of variable length data fields. Allowing for 60 characters should be sufficient. Within the Code 128 specification, bar codes can be automatically linked together by your B-8

RT1700 Radio Data Terminal User’s Guide

Page 123

APPENDIX B

"

Barcode Symbologies terminal. If you anticipate this occurring, you should allow for more characters (the terminal limit is 100 characters. The Application Identifier Standard that is part of the UCC/EAN Shipping Label concept, is designed to complement, rather than replace, other UCC/ EAN standards. Most UCC/EAN standards are designed primarily for identification of products. Several industries expressed the need to standardize more than product identification. The UCC/EAN Code 128 Application Identifier Standard supplies this tool. The standard adds versatility for inter-enterprise exchanges of perishability dating, lot & batch identification, specific container identification, units of use measure, location codes, and several other information attributes. For more detailed information on the Code 128 UCC/EAN Shipping Label bar code and Application Identifier Standard, refer to the UCC/EAN-128 APPLICATION IDENTIFIER STANDARD specification. 2 of 5 (Straight 2 of 5)

The code 2 of 5 (Straight 2 of 5 Code) is designed primarily for: "

Warehouse inventory handling

"

Identification of photo finishing envelopes

"

Airline tickets

"

Baggage and cargo handling

Code 2 of 5 is simple and straightforward. All information is contained in the widths of the bars, with the spaces serving only to separate the individual bars. Bars can either be wide or narrow; the wide bars are usually three times wider than the narrow bars. Spaces may be any reasonable width but are typically equal to the narrow bars. Narrow bars are identified as zero bits and wide bars as one bits. Remember the code structure by associating the bar positions from left to right with weighting factors 1, 2, 4, 7, and parity. Exceptions to this rule are zero, start, and stop. This is a discrete code since the white spaces between the characters are not part of the code. Because the white spaces carry no information, their dimensions are not critical. RT1700 Radio Data Terminal User’s Guide

B-9

Page 124

APPENDIX B

"

Barcode Symbologies

This code is self-checking, meaning a scanner passing through a printing void would detect the proper ratio of wide bars to total bars. When the scanner spots an error, a nonread will occur. I 2 of 5

I 2 of 5 (Interleaved 2 of 5 Code) is an all numeric symbology, widely used for warehouse and heavy industrial applications. It is often used in the automobile industry. You can place the I 2 of 5 code on smaller labels than standard UPC symbology requires. I 2 of 5 also provides more flexibility on the type of material it can printed on. Interleaved 2 of 5 Code gets its name because of the way the bar code is configured. I 2 of 5 is the same as 2 of 5 code with one exception: bars and spaces both carry information. Bars represent the odd number position digits, while spaces represent the even number position digits. The two characters are interleaved as one. Messages encoded with this symbology must use an even number of characters since two numeric characters are always interleaved together. When programming the RT1700 Radio Data Terminal for I 2 of 5 symbology, the length of the symbology used in your application must be programmed at the menu setup prompt. Keep in mind that the bar code length must be an even number and no longer than 32 characters. The terminal allows four I 2 of 5 lengths to be programmed into it at the same time. CI 2 Of 5

Computer Identics designed this bar code symbology. The purpose was to provide for higher information density with the 2 of 5 family while encoding information in both the black bars and the white spaces. Such an encoding technique eliminates the interelement spaces. Comparing it to the I 2 of 5, this eliminates four modules per character, resulting in a 28--33% information density improvement. Each character in this symbology implements this improved efficiency. Each character includes three black bars and two white spaces, plus one intercharacter space. The use of the intercharacter space classifies this code as a discrete type. B-10

RT1700 Radio Data Terminal User’s Guide

Page 125

APPENDIX B

"

Barcode Symbologies

Plessey

Plessey finds its origin in the pulse width modulated (PWM) code developed in England. It is widely used for shelf markings in grocery stores. Pulse width modulated codes represent each bit of information by a bar and space pair. A zero bit consists of a narrow bar followed by a wide space, while a one bit consists of a wide bar followed by a narrow space. It is mainly a numeric symbology (0--9) with six extra characters available for assigning any symbol or letter desired. Plessey codes are not self-checking and employ a variety of check characters. This symbology limits what information can be encoded. It is not considered for new applications.

RT1700 Radio Data Terminal User’s Guide

B-11

Page 126

APPENDIX B

B-12

"

Barcode Symbologies

RT1700 Radio Data Terminal User’s Guide

Page 127

Appendix C Keyboard Overlays "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

General Information This appendix shows the keyboard overlays for Native, 5250, 3270, and VT220 host emulations.

RT1700 Radio Data Terminal User’s Guide

C-1

Page 128 read from a scan by OCR; it may hold reading errors

APPENDIXC «

Keyboard Overlays

SCAN

IBC AY

Oooo ( 2! 5 me Jf 5 CIO Cit Y( ; OOo00 CC dC Y( }O

OO000. OOOO: IMO CI fe) Zz

C [ | ( |

RIVITOO scenes

Figure C-1 Native K eyboard Overlay

C-2 RT1700 Radio Data Terminal User's Guide

Page 129 read from a scan by OCR; it may hold reading errors

APPENDIX C

Keyboard Overlays kW

&

SCAN

CO

Ww

Ww

J\\/

Fg Fi7) F108 OF AT FID 92 F: onvorr F9,, r 2

FI3 F21 «F44 - F22 FID Fes FIG F24

“> (

) C

( at

Jo. LY VW (Ly so wl NL 4

341-232-002 5250

EX ; ; EL ““ a SYS REQ PRINT 1 ROL ( JL Jt ERASE INPUT INSERT = ° ROLI™ > ( >) JS [ | XK / CLEAR HELP ATIN ~) (- > CJL JL FIELD- FIELD+ DUP xe io > ( AV 1ITOO senes J Figure C-2 5250 K eyboard Overlay

RT1700 Radio Data Terminal User's Guide C-3

Page 130 read from a scan by OCR; it may hold reading errors

APPENDIX C «Keyboard Overlays kW AW SCAN ON/OFF '9 ,, LOS eed Sal Gad GD OOdO LICJLIJCIUI OO000

Oondown CICIJICIJICILI OOOO:

HOME ! DEL CLR MENU @ 3

CICICIC)

LL

5

ARV I7OOG scenes

Figure C-3 3270 Keyboard Overlay