The text of a manual · part 12 of 15
RT1700 Radio Data Terminal User's Guide, pages 111 to 120
Pages 111 to 120 of 150
The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Norand 1700
Page 111
Appendix A "
Specifications
900 MHz Radio Option NIC*
Device
Model Name
Type III
6710 Access Point . . . . . . . . PEN*KEYR 6400 . . . . . . . . PEN*KEY 6600 . . . . . . . . . . . . . PEN*KEY 6100 . . . . . . . . . . . . .
RM160 RM160 RM160 RM160
Radio modules
RT1100 . . . . . . . . . . . . . . . . . . . . RM60, RM70, RM70LR (radio modules) RT1700 . . . . . . . . . . . . . . . . . . . . RM60, RM70, RM70LR (radio modules)
*Consult a sales representative for availability. NIC Specifications
Following are networking specifications for the 900 MHz NIC. Frequency band:
902--928 MHz spread spectrum direct sequence
Range:
Up to 1300 feet line of sight
Coverage:
100,000--350,000 square feet in typical indoor installations
Data rate:
90, 225, or 450 Kbps (depends on installation)
Channelization:
7 @ 90 Kbps, 1 @ 225 or 450 Kbps
Client driver:
ODI
Software compatibility
Requires priopietary communications software resident in the 6710 access point
Output power:
250 mW
MAC protocol:
Open wireless LAN MAC radio protocol
Regulatory compliance:
FCC 15.247; Industry Canada RSS 210 (Consult a sales representative for availability.)
RT1700 Radio Data Terminal User’s Guide
A-5
Page 112
Appendix A " Specifications
Synthesized UHF Radio Option NIC*
Device
Model Name
Type II (tethered)
6710 Access Point . . . . . . . PE
RM111
RT1100 . . . . . . . . . . . . . . . . . . . . RM11, RM31 (radio modules) RT1700 . . . . . . . . . . . . . . . . . . . . RM11, RM31 (radio modules)
*Consult a sales representative for availability. NIC Specifications
Following are networking specifications for the synthesized UHF NIC. Frequency band:
A-6
430--450 MHz or 450--470 MHz, four-level FSK (frequency shift keying)
Range:
Up to 3500 feet line of sight
Coverage:
800,000 square feet in typical indoor installations
Data rate:
19.2 Kbps (14.4 Kbps with forward error correction)
Channelization:
20 KHz or 25 KHz
Client driver:
ODI
Software compatibility
Requires proprietary communications software resident in the 6710 access point
Output power:
500 mW
MAC protocol:
Open wireless LAN MAC radio protocol
Regulatory compliance:
FCC Parts 15, 90; Industry Canada RSS 119; ETS 300-220; FTZ 2014 (Germany); CE Mark (Europe) (Consult a sales representative for availability)
RT1700 Radio Data Terminal User’s Guide
Page 113
Appendix A "
Specifications
Proxim 2.4 GHz Radio Option Access Point NIC*
Device
Model Name
Type III
6710 Access Point
RM180
*Requires proprietary communications software resident in the access point. Wireless Station NIC*
Device
Model Name
Type III
PEN*KEY 6400 . . . . . . . . . . PEN*KEY 6600 . . . . . . . . . . .
RM180 RM180
Type II
Laptops and notebooks . . . . . .
RM185
Mini-ISA
PEN*KEY 6100 . . . . . . . . . . . RT1100 . . . . . . . . . . . . . . . . . .
RM280 RM80, RM90, RM90LR (radio modules) RM80, RM90, RM90LR (radio modules)
RT1700 . . . . . . . . . . . . . . . . . . ISA
Desktops . . . . . . . . . . . . . . . .
RM380
*Consult a sales representative for availability. NIC Specifications
Following are networking specifications for the Proxim 2.4 GHz NIC. Frequency band:
2.401--2.480 GHz SST frequency hopping
Range:
Up to 500 feet line of sight
Coverage:
25,000 ft2 (2,322 m2) typical indoors
Data rate:
800 Kbps or 1.6 M bps, manual or autoselect
Client drivers:
ODI and NDIS (v. 2.0.1/DOS and Windows)
6710 & 6910 (access point/gateway)
Requires proprietary communications software in the access point or access point/gateway
Ethernet compatibility:
Ethernet packet types and addressing
Output power:
100 mW
MAC protocol:
RangeLAN2
Regulatory compliance:
FCC 15.247; Industry Canada RSS 210; European Union ETS 300-328 (Consult a sales representative for availability.) RT1700 Radio Data Terminal User’s Guide
A-7
Page 114
Appendix A " Specifications
Radio and Scanner Modules
A-8
Module
Description
RM11
UHF radio
RM31
UHF radio with integrated, standard-range scanner or longrange scanner
RM60
900 MHz radio
RM70
900 MHz radio with integrated, standard-range scanner
RM70LR
900 MHz radio with integrated, long-range scanner (such as used on a forklift)
RM80
2.4 GHz radio
RM90
2.4 GHz radio with integrated, standard-range scanner
RM90LR
2.4 GHz radio with integrated, long-range scanner (such as used on a forklift)
RT1700 Radio Data Terminal User’s Guide
Page 115
Appendix B Bar Code Symbologies "
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
Introduction This appendix briefly describes each bar code symbology that can be decoded by the terminal. It explains some of the general characteristics of each bar code type, and where they are generally used. The bar code symbologies you want the terminal to decode must be enabled (turned on). Bar code symbologies can be enabled through the terminal parameter menus, or from your host computer. Once the terminal correctly decodes a bar code, the terminal encodes data with descriptive information about the symbol. " NOTE:
Each bar code symbology you enable uses a certain amount of the terminal ROM. As more bar codes are enabled, you may notice an increase in the terminal response time (the amount of time terminal takes to process data). To ensure the fastest response time possible, only enable the bar code symbologies you intend to scan.
Table B-1 shows the bar code string formats.
RT1700 Radio Data Terminal User’s Guide
B-1
Page 116
APPENDIX B
"
Barcode Symbologies
Table B-1 Bar Code Data String Formats
Type Code 0
Data Bar Code Type UPC short
**Data Format nddddddc
*Data Length 8
1
EAN short fndddddc
8
2
UPC long nddddddddddc
12
3
EAN long fnddddddddddc
13
4
UPC short add-on 2 nddddddcaa
10
5
EAN short add-on 2 fndddddcaa
10
6
UPC long add-on 2 nddddddddddcaa
14
7
EAN long add-on 2 fnddddddddddcaa
15
8
UPC short add-on 5 nddddddcaaaaa
13
9
EAN short add-on 5 fndddddcaaaaa
13
:
UPC long add-on 5 nddddddddddcaaaaa
17
;
EAN long add-on 5 fnddddddddddcaaaaa
18
<
Interleaved 2 of 5 d......d
1 to 200
=
Straight 2 of 5 d......d
1 to 200
Z
Computer Identics 2 of 5 d......d
1 to 200
>
Plessey d......dc
2 to 200
@
CODABAR sd....ds
3 to 200
A
ABC CODABAR sd....ds
6 to 200
S
Code 11 d......d
1 to 200
P
Code 39 d......d
1 to 200
Q
Extended Code 39 d......d
1 to 200
R
Code 93 d......d
1 to 200
J
Code 128 d......d
1 to 200
]C1
Code 128 UCC/EAN d......d
1 to 200
B-2
RT1700 Radio Data Terminal User’s Guide
Page 117
APPENDIX B
"
Barcode Symbologies
If MOD 10 or MOD 11 check digits are enabled, the digit falls at the end of a bar code data string. Each check digit enabled extends the length of the bar code data string by 1 character. Bar code data definitions: " n = number system digits
" d = bar code digits
" c = check digits
" f = EAN flag 1 characters
" a = add on code digits
" s = start and stop digits
Bar Code Symbology Many bar code symbologies are in existence today. Most of these were developed to meet the needs of a specific industry (like the food and beverage industry) or data collection and tracking system. No two products have the same bar code. Industries that use a particular type of bar code symbology form committees, or participate in national institutes, that issue (to a particular product), regulate, and track the bar codes of that symbology. This ensures that each organization using that bar code symbology conforms to its standards and that no bar code is assigned to more than one product. Without a governing body, bar coding would not work. The bar code symbologies that (when enabled) can be decoded by the terminal include the following: "
UPC (Universal Product Code) with or without add-ons
"
EAN (European Article Numbering Code) with or without add-ons
"
Codabar
"
C11 (Code 11)
"
C39 (Code 39)
"
C93 (Code 93)
"
C128 (Code 128) RT1700 Radio Data Terminal User’s Guide
B-3
Page 118
APPENDIX B
"
Barcode Symbologies
"
2 of 5 (Straight 2 of 5)
"
CI 2 of 5 (Computer Identics 2 of 5 Code)
"
I 2 of 5 (Interleaved 2 of 5 Code)
"
Plessey
The following paragraphs briefly describe each of these symbologies. UPC
The UPC (Universal Product Code) symbology is used throughout the grocery and retail industries. This bar code symbology identifies both the product and its producer. The UPC symbol is 12 characters long. The first character of the UPC symbol is a number system character, such as 0 for grocery items and 3 for drug and health related items. The UPC symbology is intended for use only in these retail environments: "
Grocery stores
"
Convenience stores
"
General merchandise stores
Some retail items are so small that the standard bar code cannot fit on the package. When this occurs, a shorter version of the UPC symbology is permitted. This is called UPC-E, which is six characters long (eight with number system and check digit). It is about one-half the size of a standard UPC bar code. EAN
EAN (European Article Numbering Code) is similar to the UPC symbology. The only difference is that EAN has 13 characters, using the first two as a country identifier. The EAN symbology is used throughout most of Europe in the retail environment. Although similar to UPC symbology, the two are not interchangeable.
B-4
RT1700 Radio Data Terminal User’s Guide
Page 119
APPENDIX B
"
Barcode Symbologies
Codabar
Codabar was developed for retail price-labeling systems. Today it is widely accepted by: "
Libraries
"
Medical industries
"
Photo finishing services
Codabar is a discrete, self-checking code with each character represented by a stand-alone group of four bars and three intervening spaces. Four different start or stop characters are defined and designated a, b, c, and d. These characters are constructed with one wide bar and two wide spaces. A complete Codabar symbol begins with one of the start or stop characters followed by a number of data characters and ends in a start or stop character. Any of the start or stop characters may be used on either end of the symbol. It is possible, then, to use the 16 unique start or stop combinationst to identity label Since Codabar is variable length, discrete, and self-checking, it is a versatile symbology. The width of space between characters is not critical and may vary significantly within the same symbol. The character set consists of 0 through 9, -, $, :, /, ., and +. The specific dimensions for bars and spaces in Codabar optimize performance of certain early printing and reading equipment. Codabar has 18 different dimensions for bar and space widths. So many different dimensions often result in labels printed out of specification and cause Codabar printing equipment to be more expensive. C11 (Code 11)
Code 11 satisfies the requirements for a very high density, discrete numeric bar code. The name Code 11 derives from 11 different data characters that can be represented, in addition to a start or stop character. The character set includes the 10 digits and the dash symbol. Each character is represented by a stand alone group of three bars and two intervening spaces. Although Code 11 is discrete, it is not self-checking. A single printing defect can transpose one character into another valid character. One or two check digits help maintain data integrity. RT1700 Radio Data Terminal User’s Guide
B-5
Page 120
APPENDIX B
"
Barcode Symbologies
The specifications for Code 11 suggest that this code should have a narrow element width of 7.5 mils. This results in an information density of 15 characters per inch. C39
C39 (Code 39) is the most widely used symbology among the industrial bar codes. Many major companies, trade associations, and the federal government use this code. Its main feature is the ability to encode messages using the full alphanumeric character set, seven special characters, and ASCII characters. Programming for this symbology can be for any length that the application requires. The application program for the terminal handles symbology that is at least 1 character but no more than 32 characters in length. When programming the terminal for Code 39, it is important to set the symbology limits as close as possible to the minimum and maximum bar code lengths being scanned. This saves processing time and conserves battery power. Extended Code 39 (Concatenation)
This bar code symbology allows multiple scans to accumulate as a continuous data string. It can be used to streamline data communication. If the first data character of a symbol is a space, the reader may be programmed to append the information contained in the remainder of the symbol to a storage buffer. This operation continues for all successive symbols that contain a leading space, with messages being added to the end of previously stored ones. When a message is read which does not contain a leading space, the contents are appended to the buffer, the entire buffer is transmitted, and the buffer is cleared. Encoded Code 39 (Full ASCII)
If the bar code reader has been programmed for the task, it is possible to encode the entire ASCII character set (128 characters) by using two character sequences made up of one of the symbols ($, ., %, /) followed by one of the 26 letters. C93
The introduction of Code 93 provided a higher density alphanumeric symbology designed to supplement Code 39. The Code 93 data characters B-6
RT1700 Radio Data Terminal User’s Guide